排序方式: 共有11条查询结果,搜索用时 312 毫秒
1.
Magnuson ML Kelty CA Urbansky ET Owens JH Kelty KC Speth TF 《Journal of environmental monitoring : JEM》2002,4(1):102-108
Analytical chemistry is an important tier of environmental protection and has been traditionally linked to compliance and/or exposure monitoring activities for environmental contaminants. The adoption of the risk management paradigm has led to special challenges for analytical chemistry applied to environmental risk analysis. Namely, methods developed for regulated contaminants may not be appropriate and/or applicable to risk management scenarios. This paper contains examples of analytical chemistry applied to risk management challenges broken down by the analytical approach and analyte for some selected work in our laboratory. Specific techniques discussed include stable association complex electrospray mass spectrometry (cESI-MS), gas chromatography-mass spectrometry (GC-MS), split-flow thin cell (SPLITT) fractionation and matrix-assisted laser desorption time of flight mass spectrometry (MALDI-ToF-MS). Specific analytes include haloacetic acids (HAA9), perchlorate, bromate, triazine degradation products, metal-contaminated colloids and Cryptosporidium parvum oocysts. 相似文献
2.
Charles J. Weschler Stephen P. Kelty Joyce E. Lingousky 《Journal of the Air & Waste Management Association (1995)》2013,63(6):624-629
As part of an energy conservation program recently implemented by the Bell System, fans in many telephone equipment buildings now operate only when necessary to bring the temperature within allowable limits, rather than continuously. In the study reported here the effects of fan operation on indoor-outdoor dust relationships were monitored at 2 representative telephone offices. Automatic dichotomous samplers were used to collect fine and coarse aerosol particles inside telephone equipment buildings at Wichita, KS and Lubbock, TX. At both sites, outdoor samples (roof top) were collected at the same time as the indoor samples. During the tests the building fans were repetitively cycled between 2-week intervals of continuous fan operation and 2-week intervals of intermittent fan operation. The indoor dust concentrations typically increased when the fans were off. The results indicate that this increase was due to loss of constant filtration, but not due to loss of building pressurlzation (i.e., filtration of the recirculated air is largely responsible for the lower dust levels when the fans are running continuously). An expression is derived for the relative dust increase when the building fans are switched off. Among other factors, the relative increase is directly proportional to the efficiency of the building filters and to the rate at which air is recirculated through them. The present findings can be extended to similar buildings. 相似文献
3.
Thomas Minning Darren A. Lytle Maily Pham Keith Kelty 《Environmental monitoring and assessment》2015,187(6):383
Distinguishing between soluble and particulate lead in drinking water is useful in understanding the mechanism of lead release and identifying remedial action. Typically, particulate lead is defined as the amount of lead removed by a 0.45-μm filter. Unfortunately, there is little guidance regarding selection of filter membrane material and little consideration to the possibility of the sorption of dissolved lead to the filter. The objective of this work was to examine the tendency of 0.45-μm syringe filter materials to adsorb lead. Tests were performed with water containing 40 and 24 μg/L soluble lead at pH 7 buffered with 50 mg C/L dissolved inorganic concentration (DIC). The amounts of lead sorbed greatly varied by filter, and only two filter types, polypropylene and mixed cellulose esters, performed well and are recommended. Great care must be taken in choosing a filter when filtering soluble lead and interpreting filter results. 相似文献
4.
建立我国生态环境标准体系的初步构想 总被引:9,自引:0,他引:9
我国的生态环境标准极其薄弱,建立生态环境标准体系是我国生态环境保护的迫切需要。借鉴我国目前针对污染防治的环境标准体系,提出了我国生态环境标准体系的基本框架,以及生态环境标准制订的原则和重点。 相似文献
5.
Vollenweider P Woodcock H Kelty MJ Hofer RM 《Environmental pollution (Barking, Essex : 1987)》2003,125(3):467-480
Leaf ozone symptoms in natural ecosystems are increasingly reported but ozone effects on tree growth and the mediation of site conditions are still little documented. This study tests two hypotheses: (1) leaf injury in black cherry is associated with decline in radial growth, (2) symptoms are more prevalent on mesic sites. On sites supporting black cherry across Massachusetts, tree growth and leaf ozone injury were surveyed in 1996 using a randomized plot network established in the 1960s. Forty-seven percent of 120 trees sampled for ozone symptoms were symptomatic with generally low levels of injury. Over a 31-year period symptomatic trees had 28% lower stem growth rates than asymptomatic trees. Ozone symptom expression was enhanced in well growing stands on moister, cooler and more elevated sites. Ozone appeared to increase environmental stress and had a more pronounced effect on growth in better growing black cherry stands. This complicates management decisions as thinning increases growth and moisture availability. 相似文献
6.
针对目前生态气象监测轨道业务的特点,结合工作的实际需要,运用C和C++语言建立了生态气象监测评估业务平台。在程序设计中,采用了生成中间交换文件的结构组织,能够对各模块的输出结果进行详尽直观的分析,并提供了等值线色斑图与区域填充等多种图形绘制方式。该系统可处理AVHRR和EOS/MODIS卫星遥感资料,对气象观测报文进行解译、数据分类管理和质量控制,统计计算水体密度指数、湿润指数、植被覆盖指数、土地退化指数、灾害指数和生态质量综合评价指标,以图形、图像的形式输出生态气象监测评估产品,实现了卫星遥感与生态气象地面监测数据的有效组织和智能化管理。将系统应用于湖南省生态质量气象评价,业务化运行的结果表明,该系统具有较好的业务实用性。〖HJ1〗〖HJ〗
〖HT5”H〗 相似文献
〖HT5”H〗 相似文献
7.
William D. Shuster Dennis Lye Armah De La Cruz Lee K. Rhea Katharine O'Connell Amanda Kelty 《Journal of the American Water Resources Association》2013,49(4):753-765
The collection, storage, and reuse of rainwater collected in rain barrels from urban rooftop areas assists municipalities in achieving stormwater management objectives and in some areas also serves as an adjunct resource for domestic water supplies. In this study, rainwater reuse and levels of select microbial indicators were monitored for six residential rain barrels located in the Shepherd Creek watershed of Cincinnati, Ohio. Water from rain barrels typically had poor microbial quality and was used for watering indoor and outdoor plants. Rain barrel water chemistry was slightly acidic, exhibited wide ranges in conductivity, turbidity, and total organic carbon (TOC) concentrations and gave no evidence of the presence of cyanobacterial microcystin toxins. Selected microbial water‐quality indicators indicated that counts of total coliform and enterococci were consistently above U.S. Environmental Protection Agency standards for secondary recreational contact water‐quality standards. Residential rain barrels can provide water appropriate for low‐contact reuses (such as plant watering), although there may be transient periods of high levels of indicator bacteria in the collected water. 相似文献
8.
9.
Cafer T. Yavuz J. T. Mayo Carmen Suchecki Jennifer Wang Adam Z. Ellsworth Helen D’Couto Elizabeth Quevedo Arjun Prakash Laura Gonzalez Christina Nguyen Christopher Kelty Vicki L. Colvin 《Environmental geochemistry and health》2010,32(4):327-334
Arsenic contamination in groundwater is a severe global problem, most notably in Southeast Asia where millions suffer from acute and chronic arsenic poisoning. Removing arsenic from groundwater in impoverished rural or urban areas without electricity and with no manufacturing infrastructure remains a significant challenge. Magnetite nanocrystals have proven to be useful in arsenic remediation and could feasibly be synthesized by a thermal decomposition method that employs refluxing of FeOOH and oleic acid in 1-octadecene in a laboratory setup. To reduce the initial cost of production, $US 2600/kg, and make this nanomaterial widely available, we suggest that inexpensive and accessible “everyday” chemicals be used. Here we show that it is possible to create functional and high-quality nanocrystals using methods appropriate for manufacturing in diverse and minimal infrastructure, even those without electricity. We suggest that the transfer of this knowledge is best achieved using an open source concept. 相似文献
10.
城市的发展改变了许多河流的自然水文环境,并导致河流生态系统中水质、物理生境和生物完整性下降。评估受损河流水体修复的效果,需要结合物理、化学的参数,以及对生物结构、多样性和过程的影响。构建了包含河流水力、水质、水生生物、河岸带及物理结构5个方面15个指标的城市河流生态修复评估指标体系,运用群组决策的层次分析法(AHP),确定了各指标的权重,重要性排序前5位依次为:水质污染指数、鱼类IBI、水源补给量、藻类多样性、透明度。并以我国南方城市岐江河整治修复状况为例进行综合评价,结果表明,河流生态系统修复评估结果为可以接受,体现了河流整治工程使河流水质、生态的状况有所改善,但河流生态系统恢复需要较长的周期,修复初期生态系统仍处于受损状态。〖 相似文献