全文获取类型
收费全文 | 119篇 |
免费 | 1篇 |
国内免费 | 7篇 |
专业分类
废物处理 | 19篇 |
环保管理 | 7篇 |
综合类 | 12篇 |
基础理论 | 16篇 |
污染及防治 | 40篇 |
评价与监测 | 21篇 |
社会与环境 | 9篇 |
灾害及防治 | 3篇 |
出版年
2023年 | 4篇 |
2022年 | 8篇 |
2021年 | 11篇 |
2020年 | 2篇 |
2019年 | 2篇 |
2018年 | 4篇 |
2017年 | 6篇 |
2016年 | 5篇 |
2015年 | 5篇 |
2014年 | 3篇 |
2013年 | 23篇 |
2012年 | 8篇 |
2011年 | 13篇 |
2010年 | 6篇 |
2009年 | 4篇 |
2008年 | 5篇 |
2007年 | 3篇 |
2006年 | 1篇 |
2004年 | 1篇 |
2003年 | 1篇 |
2002年 | 3篇 |
2001年 | 4篇 |
2000年 | 1篇 |
1992年 | 1篇 |
1991年 | 1篇 |
1989年 | 1篇 |
1987年 | 1篇 |
排序方式: 共有127条查询结果,搜索用时 15 毫秒
1.
Nathaniel Solomon Prince Alam Md. Shabbir Murshed Muntasir Mahmood Haider Ahmad Paiman 《Environmental science and pollution research international》2021,28(35):47957-47972
Environmental Science and Pollution Research - In the current century, the G7 countries have attached more importance to energy security, and have prioritized low-carbon sources which have... 相似文献
2.
Alamgir Hossain Jamal Naser Monzur Alam Imteaz 《Environmental Modeling and Assessment》2011,16(4):359-367
This paper presents comprehensive 3D numerical investigations on depositions of particles flowing through a horizontal pipe
loop consisting of four bends. The multiphase mixture model available in FLUENT 6.2 was used in this study. In this numerical
simulation, five different particle sizes have been used as secondary phases to calculate real multiphase effect in which
inter-particle interaction has been considered. The deposition of particles along the periphery of the pipe wall was investigated
as a function of particle size and fluid velocity. The simulations showed that near the upstream of the bends, maximum particle
concentration occurred at the bottom of the pipe. However, downstream the bends, the maximum particle concentration occurred
at an angle of 60° from the bottom. The larger particles clearly showed deposition near the bottom wall except downstream.
As expected, the smaller particles showed less tendency of deposition and lesser at higher velocity. This numerical investigation
showed qualitative agreement with the experiments conducted by Commonwealth Scientific and Industrial Research Organisation,
Melbourne team for similar conditions. 相似文献
3.
The physical, chemical and biological characteristics of the wastewater of Natural Gas Fertilizer Factory Ltd. Fenchuganj, Sylhet were determined through extensive laboratory tests in the months of March, July, October and December of the year 2005. Concentration of Suspended Solids was within the range of 445 to 950 mg/L. Bangladesh Industrial Effluent Standards for Suspended Solids is 100 mg/L. Suspended Solids were found above the limit in all the samples. Concentration of Dissolved Solids was found to vary from 576 to 1,456 mg/L. Bangladesh Industrial Effluent Standards, for Dissolved Solids is 2,100 mg/L. Dissolved Solids were found within the limit. Concentration of BOD(5) was found to vary from 4.5 to 8.4 mg/L. Bangladesh Industrial Effluent Standards for BOD(5) is 50 mg/L. For the year 2005, the BOD(5) was found below the limit in all the samples. Dissolved Oxygen of the wastewater was found to be between 2.0 to 3.0 mg/L, which do not satisfy the standard (4.5-8 mg/L). Oil and grease concentration were found in the range of 28 to 68 mg/L, whereas the standard is 10 mg/L for discharge into the inland surface water. In 2005, concentration of Cr(+ 6) was found to vary from 0.01 to 0.156 mg/L in the wastewater. Bangladesh Industrial Effluent Standards, for Cr(+6) is 0.1 mg/L. The concentration of chromium was found above the limit in three samples. Concentration of NO(3) was found to vary from 4.5 to 15.2 mg/L in the wastewater. Bangladesh Industrial Effluent Standards for nitrate is 10 mg/L. The nitrate was found above the limit in three samples. Maximum concentration of ammonia in lagoon 1 was found 1,710 mg/L in month of December. Bangladesh Industrial Effluent Standards for ammonia nitrogen is 100 mg/L. For the year 2005, the ammonia nitrogen was found above the limit in all samples. 相似文献
4.
Groundwater vulnerability assessment using DRASTIC and Pesticide DRASTIC models in intense agriculture area of the Gangetic plains,India 总被引:1,自引:0,他引:1
Delineating areas susceptible to contamination from anthropogenic sources form an important component of sustainable management of groundwater resources. The present research aims at estimating vulnerability of groundwater by application of DRASTIC and Pesticide DRASTIC models in the southern part of the Gangetic plains in the state of Bihar. The DRASTIC and Pesticide DRASTIC models have considered seven parameters viz. depth to water level, net recharge, aquifer material, soil material, topography, impact of vadose zone and hydraulic conductivity. A third model, Pesticide DRASTIC LU has been adopted by adding land use as an additional parameter, to assess its impact on vulnerability zonation. The DRASTIC model indicated two vulnerable categories, moderate and high, while the Pesticide DRASTIC model revealed moderate, high and very high vulnerable categories. Out of the parameters used, depth to water level affected the vulnerability most. The parameter caused least impact was topography in DRASTIC, while in case of Pesticide DRASTIC and Pesticide DRASTIC LU models, the parameter was hydraulic conductivity. A linear regression between groundwater NO3 concentrations and the vulnerability zonation revealed better correlation for Pesticide DRASTIC model, emphasising the effectiveness of the model in assessing groundwater vulnerability in the study region. Considering all three models, the most vulnerable areas were found to be concentrated mainly in two zones, (i) in the south-western part along Ekangarsarai-Islampur patch and (ii) around Biharsharif-Nagarnausa area in the central part. Both zones were characterised by intensive vegetable cultivation with urban areas in between. 相似文献
5.
Se-Won Park Jang-Soo Lee Won-Seok Yang Md Tanvir Alam Yong-Chil Seo Sang-Yeop Lee 《Journal of Material Cycles and Waste Management》2018,20(2):823-831
Gasification experiments for sawdust were conducted using a fixed bed reactor at 900 °C by varying the secondary oxidant injection ratio to determine the optimal conditions for tar removal along with the enhancement of gasification efficiency. Secondary oxidant was injected as an oxidant at the top zone of the gasifier in varying ratios of 10–30% of the total amount of oxidant. This method was based on the primary method of tar removal and gasification efficiency improvement by thermal cracking of tar. Various gasification performance parameters were evaluated and tar content was estimated by measuring the fluctuation of weight of the activated carbon filter. The results showed that the concentration of tar in the producer gas decreased by injecting the secondary oxidant, even though syngas yield decreased. The recycling potential of the char produced in the gasification experiments was also assessed with the purpose of utilizing char as an adsorbent by determining its surface area and pore volume. The results demonstrated that the char produced from the gasification experiment had similar quality to that of the activated carbon used in this experiment. 相似文献
6.
7.
Md. Ibrahim H. Mondal A. B. M. Fakrul Alam 《Journal of Polymers and the Environment》2013,21(1):280-285
Cellulose acetate (CA) was synthesized from knitted rag, a cellulosic waste of Textile and Garment industries, in the glacial acetic acid, and subsequently acetic anhydride (Ac2O) in presence of concentrated H2SO4 reaction medium. A low to high substitution products were obtained from single step up to seven steps acetylation of cellulose. In this way, it was possible to produce low cost and different grades or substituted acetylation derivatives of cellulose. The synthesized CA was characterized and investigation of its physical characteristics was done. Solubility, acetyl content, acetic acid content, degree of substitution, and molecular weight of CA increased gradually with the increase of the number of reaction steps attaining optimum value at the fourth step. The acetyl and acetic acid content of CA were increased from 39.95 % to 44.25 %, and from 55.73 % to 61.73 % respectively. Similarly, degree of substitution and molecular weight of CA were increased from 2.47 to 2.94, and from 74,249 to 121,437 respectively. 相似文献
8.
A GFP-based bacterial biosensor with chromosomally integrated sensing cassette for quantitative detection of Hg(II) in environment 总被引:3,自引:0,他引:3
Himanshu Priyadarshi Absar Alam Gireesh-Babu P Rekha Das Pankaj Kishore Shivendra Kumar Aparna Chaudhari 《环境科学学报(英文版)》2012,24(5):963-968
A mercury biosensor was constructed by integrating biosensor genetic elements into E. coli JM109 chromosome in a single copy number, using the attP/attB recombination mechanism of λphage. The genetic elements used include a regulatory protein gene (merR) along with operator/promoter (O/P) derived from the mercury resistance operon from pDU1358 plasmid of Serratia marcescens. The expression of reporter gene gfp is also controlled by merR/O/P. Integration of the construct into the chromosome was done to increase the stability and precision of the biosensor. This biosensor could detect Hg(II) ions in the concentration range of 100-1700 nmol/L, and manifest the result as the expression of GFP. The GFP expression was significantly different (P ≤ 0.05) for each concentration of inducing Hg(II) ions in the detection range, which reduces the chances of misinterpretation of results. A model using regression method was also derived for the quantification of the concentration of Hg(II) in water samples. 相似文献
9.
The objectives of this study were to evaluate metal contamination of drinking water resulting from the corrosion of distribution pipes and its significance to human health. A community in Dhahran, which is served from its own desalination facilities, was chosen for this study. About 150 drinking water samples were collected and analyzed for metal concentrations using an inductively coupled argon plasma analyzer. It was found that copper, iron and zinc in the drinking water increased during its transportation from the desalination plant to the consumers. This increase was related to the length and material of distribution pipes. Concentrations of copper and zinc were increased during overnight storage of water in the appliances. Metal concentrations found in this study are discussed with reference to human health. 相似文献
10.
Hussain Majid Khan Alam Pierre Madl Werner Hofmann 《Environmental monitoring and assessment》2013,185(6):5265-5276
Ambient aerosol concentrations along the roadside of metropolitan cities of Pakistan were measured using a Grimm 1.109 dust monitor. Considering the high ambient aerosol concentrations, regional lung deposition of aerosol particles in the human respiratory tract was calculated to assess extent of exposure. Lung deposition was computed in terms of mass concentration and the associated surface area for 12 male traffic wardens using the latest version of the stochastic lung deposition code Inhalation, Deposition, and Exhalation of Aerosols in the Lung. The results have revealed 4 to 10 times higher concentrations than recommended by WHO guidelines. The deposition results derived from the model disclose that extrathoracic deposition is in the range of 22 to 28 % with total lung deposition ranging from 40 to 44 % for the scanned particle window of 0.25–10 μm. Considering an average 8-h shift per day and an average breathing rate of 1.3 m3?h?1, it is approximated that in a worker, up to 1.6 mg of inhalable particle mass can deposit per day. 相似文献