首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   8篇
  免费   0篇
环保管理   3篇
评价与监测   5篇
  2012年   2篇
  2010年   2篇
  2006年   2篇
  2003年   1篇
  2002年   1篇
排序方式: 共有8条查询结果,搜索用时 31 毫秒
1
1.
The number concentration and size distribution of ultrafine particles in a S?derberg and a prebake potroom of an aluminium primary smelter have been measured using a scanning mobility particle spectrometer. The particle morphology was studied by transmission electron microscopy (TEM). The study shows the existence of elevated number concentrations of ultrafine particles in both potrooms. The main source of these particles is likely to be the process of anode changing. The ultrafine particles were measured directly at the source but could also be identified as episodes of high number concentrations in the general background air. Unlike the larger particles belonging to the 50-100 nm mode, the nanoparticle mode could not be detected in the TEM indicating that they may not be stable under the applied sampling conditions and/or the high vacuum in the instrument.  相似文献   
2.
3.
This study describes refrigeration repair workers' occupational exposures to halogenated refrigerants, focusing on difluorochloromethane (HCFC 22), tetrafluoroethane (HFC 134a) and a mixture of tri-, tetra- and pentafluoroethane (R404A) in 30 work operations. Unlike earlier reported studies, the present study includes working procedures involving welding in order to measure possible occupational exposure to decomposition products. The measurements included hydrogen fluoride (HF), hydrogen chloride (HCl), phosgene (COCl2) and volatile organic compounds (VOC). The exposures were assessed during work operations on small-scale cooling installations like refrigerators and freezers. The repair workers' occupational exposures to refrigerants were moderate, and the major part of the exposures were associated with specific working procedures lasting for relatively short periods of time (<20 min). During these exposure events the concentrations were occasionally high (up to 42434 mg m(-3)). Although welding operations lasted only for short periods of time, HF was detected in 9 out of 15 samples when HCFC 22, HFC 134a or R404A had been used. Hydrogen chloride was detected in 3 out of 5 samples in air polluted with HCFC 22. Phosgene was not detected. A large number of VOCs in various concentrations were found during welding. Except for the applied refrigerants, halogenated compounds were only found in one sample.  相似文献   
4.
5.
Alumina used in the production of primary aluminium contains Be which partly vaporises from the cryolite bath into the workroom atmosphere. Since Be may be toxic at lower exposure levels than previously thought, the personal exposure to Be among workers in 7 Norwegian primary smelters has been assessed. In total, 480 personal Respicon? virtual impactor full shift air samples have been collected during 2 sampling campaigns and analysed for water soluble Be, Al and Na using inductively coupled plasma optical emission spectrometry. In addition, water soluble F(-) has been measured by ion chromatography. The Be air concentrations in the inhalable, thoracic and respirable aerosol fractions have been calculated. The Be concentrations in the inhalable aerosol fraction vary between the different smelters. The highest GM concentration of Be in the inhalable fraction (122 ng m(-3), n = 30) was measured in the prebake pot room of a smelter using predominantly Jamaican alumina where also the highest individual air concentration of 270 ng m(-3) of Be was identified. The relative distribution of Be in the different aerosol fractions was fairly constant with the mean Be amount for the two sampling campaigns between 44-49% in the thoracic fraction expressed as % of the inhalable amount. Linear regression analysis shows a high correlation between water soluble Be, Al, F and Na describing an average measured chemical bulk composition of the water soluble thoracic fraction as Na(5.7)Al(3.1)F(18). Be is likely to be present as traces in this particulate matter by replacing Al atoms in the condensed fluorides and/or as a major element in a nanoparticle sized fluoride. Thus, the major amount of Be present in the work room atmosphere of Al smelter pot rooms will predominantly be present in combination with substantial amounts of water soluble Al, F and Na.  相似文献   
6.
The aim of this study was to characterise personal exposures to dust, acid vapours, and gases among workers in a Norwegian nitrate fertiliser production plant, as part of an ongoing epidemiological study. In total, 178 inhalable and 179 thoracic aerosol mass fraction samples were collected from randomly chosen workers (N = 141) from three compound fertiliser departments (A, B and C), a calcium nitrate fertiliser production department, nitric acid- and ammonia-production departments, and a shipping department. The overall median inhalable and thoracic aerosol mass concentrations were generally low (1.1 mg m(-3) (min-max: <0.93-45) and 0.21 mg m(-3) (min-max: <0.085-11), respectively). Workers at the compound fertiliser departments B and C had significantly higher inhalable aerosol mass air concentrations compared to the other departments (p < 0.05), except for compound fertiliser department A; however, the difference between the compound fertiliser department C and calcium nitrate department was slightly above the significant level. Workers at the compound fertiliser department A had significantly higher thoracic aerosol mass air concentrations compared to the other departments (p < 0.05), except for compound fertiliser departments B and C. The results indicate that the extrathoracic aerosol fraction of the aerosol compared to the thoracic fraction dominated in most departments. Measurement of the main constituents Ca, K, Mg, and P in the water-soluble and water-insoluble aerosol mass fractions showed that the air concentrations of these elements were low. There is, however, a shift towards more water-soluble species as the production goes from raw material with phosphate rock towards the final product of fertilisers. Overall, the arithmetic mean of water-soluble Ca in the thoracic mass fraction was 51% (min-max: 1-100). A total of 169 personal samples were analysed for HNO(3) vapour and HF. The highest median concentration of HNO(3) (0.63 mg m(-3)) was in the compound fertiliser departments B, and all measurements but four of the HF concentrations were below the LOD of 190 μg m(-3). Exposures to NH(3), CO and NO(2) were measured using direct-reading electrochemical sensors and the time weighted overall averages were all below the LODs of the respective sensors, NH(3) 2 ppm; CO 2 ppm; and NO(2) 0.2 ppm, but some short-term peaks were detected. Even though our results indicate that the workers may experience peak exposure episodes when performing job tasks such as cleaning or maintenance work, the overall air concentrations are well below what is considered to cause known health risks.  相似文献   
7.
Ice, George G., George W. Brown, John A. Gravelle, C. Rhett Jackson, Jeffrey T. Light, Timothy E. Link, Douglas J. Martin, Dale J. McGreer, and Arne E. Skaugset, 2010. Discussion –“Stream Temperature Relationships to Forest Harvest in Western Washington” by Michael M. Pollock, Timothy J. Beechie, Martin Liermann, and Richard E. Bigley. Journal of the American Water Resources Association (JAWRA) 46(4): 838-842. DOI: 10.1111/j.1752-1688.2010.00441.x  相似文献   
8.
The Respicon has been introduced as a sampler for health related measurements of airborne contaminants at workplaces. The instrument is aimed at simultaneous collection of three health related aerosol fractions: (a) the coarser inhalable fraction, defining the aerosol fraction that may enter the nose and mouth during breathing; (b) the intermediate thoracic fraction, defining the fraction that may penetrate beyond the larynx and so reach the lung; and (c) the finer respirable fraction, defining the fraction that may penetrate to gas exchange region of the lung. The instrument has a number of features attractive to occupational hygienists: in addition to providing the three aerosol fractions simultaneously, it is light and compact enough to be used as a personal sampler. yet can be a tripod mounted for area sampling, it can provide samples not only for gravimetric analysis but also microscopic and chemical analyses; and it is also available in a photometric direct-reading version. The instrument has previously been evaluated as an area sampler and, in this mode of operation, has shown reasonable accuracy in collecting respirable, thoracic and inhalable particles, the latter up to particle diameters of ca. 80 microm. Except for some scattered unpublished data there exist no systematic investigations in the Respicon's performance when used as a personal sampler in the industrial environment. In this paper, we will report on a study of side by side comparison of the Respicon with the IOM inhalable sampler, regarded as a reference instrument for the inhalable fraction. The main study was performed at six different workplaces in a nickel refinery. Statistical analysis of the gravimetrically-determined concentration data reveals consistently lower aerosol exposure values for the Respicon as compared to the IOM sampler. The data for the nickel workplaces are compared with findings from other studies. The results are interpreted in the light of the overall results and the possibility of introducing a correction factor is discussed.  相似文献   