首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   144篇
  免费   2篇
  国内免费   5篇
安全科学   4篇
废物处理   23篇
环保管理   17篇
综合类   8篇
基础理论   26篇
污染及防治   61篇
评价与监测   10篇
社会与环境   2篇
  2022年   3篇
  2021年   1篇
  2020年   1篇
  2019年   2篇
  2018年   4篇
  2017年   6篇
  2016年   6篇
  2015年   2篇
  2014年   6篇
  2013年   9篇
  2012年   6篇
  2011年   15篇
  2010年   13篇
  2009年   8篇
  2008年   12篇
  2007年   15篇
  2006年   8篇
  2005年   2篇
  2004年   11篇
  2003年   6篇
  2002年   4篇
  2001年   3篇
  2000年   2篇
  1998年   1篇
  1997年   1篇
  1992年   1篇
  1989年   2篇
  1984年   1篇
排序方式: 共有151条查询结果,搜索用时 15 毫秒
1.
Efficient removal of chlorine from PVC achieved by two-stage heat-treatment (280 and 410 degrees C) provided chlorine-free isotropic pitch containing additive. The pitch was stabilized and carbonized into porous carbons with surface areas of approximately 300 m2/g. Resultant porous carbons showed three pore structures of supermicropore, micropore and mesopore. The generation of CO2 from the decomposition of the CaCO3 additive in waste PVC is responsible for the development of porous structures. The surface area of the carbonized product increased after the removal of CaO.  相似文献   
2.
Polyvinylchloride (PVC) was successfully recycled through the solvent extraction from waste pipe with an extraction yield of ca. 86%. The extracted PVC was pyrolyzed by a two-stage process (260 and 410 degrees C) to obtain free-chlorine PVC based pitch through an effective removal of chlorine from PVC during the heat-treatment. As-prepared pitch (softening point: 220 degrees C) was spun, stabilized, carbonized into carbon fibers (CFs), and further activated into activated carbon fibers (ACFs) in a flow of CO2. As-prepared CFs show comparable mechanical properties to commercial CFs, whose maximum tensile strength and modulus are 862 MPa and 62 GPa, respectively. The resultant ACFs exhibit a high surface area of 1200 m2/g, narrow pore size distribution and a low oxygen content of 3%. The study provides an effective insight to recycle PVC from waste PVC and develop a carbon precursor for high performance carbon materials such as CFs and ACFs.  相似文献   
3.
Ambient air monitoring of PCDD/Fs and co-PCBs in Gyeonggi-do, Korea   总被引:3,自引:0,他引:3  
Kim DG  Min YK  Jeong JY  Kim GH  Kim JY  Son CS  Lee DH 《Chemosphere》2007,67(9):1722-1727
We started the monitoring for PCDD/Fs in ambient air and soil in August 2001, and co-PCBs in January 2002. Decreasing of PCDD/Fs and co-PCBs levels in ambient air were observed. The higher PCDD/Fs levels were found in winter and lower in autumn. We found that the industrial incinerators influenced the PCDD/Fs levels in ambient air. In the 2,3,7,8-substituted PCDD/Fs concentration profiles, the three major congeners occupied 67% of the total mass. In case of co-PCBs, PCB#118, #105 and #77 were observed as the main congeners. Five cluster groups discriminated by ratio of four components, O(8)CDD, 1,2,3,4,6,7,8-H(7)CDD, 1,2,3,4,6,7,8-H(7)CDF and O(8)CDF, were obtained from HCA (hierarchical cluster analysis).  相似文献   
4.
Moon HB  Yoon SP  Jung RH  Choi M 《Chemosphere》2008,73(6):880-889
Toxic organic contaminants and a macrobenthic community were assayed in sediments collected near a wastewater treatment plant (WWTP) outfall to assess the impact of WWTP discharges on an aquatic environment. Average concentrations of toxic organic contaminants in sediments from 20 locations were 96.7ng TEQ/kg dry matter for PCDD/Fs, 1.84ng TEQ/kg dry matter for dioxin-like PCBs, 29.1microg/kg dry matter for PBDEs, 411microg/kg dry matter for nonylphenols, 1021microg/kg dry matter for fecal sterols, and 928microg/kg dry matter for PAHs. Concentrations of all the organic contaminants and fecal sterols varied widely and there was a clear decrease in concentration gradients with increasing distances from the WWTP outfall. This result suggests that WWTP activities contribute to contamination by organic chemicals. A survey of benthic organisms showed the dominance of a few polychaete species, indicating a deterioration of the macrobenthic community by the WWTP discharge. Non-parametric multidimensional scaling (MDS) ordination and Spearman correlation analyses showed that organic contamination is associated with the benthic community structure. For polychaete species, the sensitive species for organic contaminants was Paraprionospio pinnata, while contaminant-tolerant species were Spiochaetopterus koreana and Capitella capitata. BIOENV analyses of all locations suggested PCDDs and PCDFs as the major contaminants influencing the structure of the macrobenthic community. The present study highlights that continuous WWTP discharges contribute to severe organic contamination and risks for the benthic community in an aquatic ecosystem.  相似文献   
5.
6.
Minimization of the formation of disinfection by-products   总被引:1,自引:0,他引:1  
The drinking water industry is required to minimize DBPs levels while ensuring adequate disinfection. In this study, efficient and appropriate treatment scheme for the reduction of disinfection by-product (DBPs) formation in drinking water containing natural organic matter has been established. This was carried out by the investigation of different treatment schemes consisting of enhanced coagulation, sedimentation, disinfection by using chlorine dioxide/ozone, filtration by sand filter, or granular activated carbon (GAC). Bench scale treatment schemes were applied on actual samples from different selected sites to identify the best conditions for the treatment of water. Samples were collected from effluent of each step in the treatment train in order to analyze pH, UV absorbance at 254 nm (UVA254), specific UV absorbance at 254 nm (SUVA254), dissolved organic carbon (DOC), haloacetic acids (HAAs) and trihalomethanes (THMs). The obtained results indicated that using pre-ozonation/enhanced coagulation/activated carbon filtration treatment train appears to be the most effective method for reducing DBPs precursors in drinking water treatment.  相似文献   
7.
This study was conducted to assess inhalation exposure to dust, endotoxin, and microorganisms (including viable bacteria, Gram-negative bacteria [GNB], and fungi) during waste collection and sorting; to identify factors affecting this exposure; and to estimate the gastrointestinal exposure to microorganisms. A total of 48 or 49 workers involved in collecting and sorting waste from households or the street were studied. Each worker carried two personal samplers in which filters were placed in the breathing zone for estimation of inhalation exposure. To assess the possibility of gastrointestinal exposure, microorganisms on the workers' faces were collected before and after work and compared with those collected from office workers. Inhalation exposure levels were categorized according to job title, waste type handled, and working conditions and were compared using analysis of variance. Multiple regression models were developed to identify those factors that substantially affected inhalation exposure. The average exposure level to total dust was 0.9 mg/m3 (range = 0.05 to 4.51 mg/m3), and the average exposure to endotoxin was 1123 EU/m3. The average respective exposure levels to bacteria, GNB, and fungi each exceeded 10(4) colony forming units (CFU)/m3. The multiple regression models found several factors that significantly explained the variation in levels of inhalation exposure to endotoxin and microorganisms; namely, sex (dust, bacteria, and GNB), job title (GNB and fungi), collection day (dust, bacteria, and GNB), temperature (endotoxin and GNB), humidity (endotoxin and fungi), and region (endotoxin) were significantly associated with exposure to these agents. In addition, the workers' faces were highly contaminated with microorganisms. In conclusion, inhalation exposure to endotoxin and microorganisms was high during waste collection and sorting, which may place workers at risk of developing various health problems, including respiratory complaints.  相似文献   
8.

Background, aims, and scope

Preschool indoor air quality (IAQ) is believed to be different from elementary school or higher school IAQ and preschool is the first place for social activity. Younger children are more susceptible than higher-grade children and spend more time indoors. The purpose of this study was to compare the indoor air quality by investigating the concentrations of airborne particulates and gaseous materials at preschools in urban and rural locations in Korea.

Methods

We investigated the concentrations of airborne particulates and gaseous materials in 71 classrooms at 17 Korean preschools. For comparison, outdoor air was sampled simultaneously with indoor air samples. Airborne concentrations of total suspended particulates, respirable particulates, lead, asbestos, total volatile organic compounds and components, formaldehyde, and CO2 were measured with National Institute for Occupational Safety and Health and/or Environmental Protection Agency analytical methods.

Results

The concentration profiles of the investigated pollutants in indoor and urban settings were higher than those in outdoor and rural areas, respectively. The ratios of indoor/outdoor concentrations (I/O) of particulates and gaseous pollutants were characterized in urban and rural preschools. Total dust concentration was highest in urban indoor settings followed by urban outdoor, rural indoor, and rural outdoor locations with an I/O ratio of 1.37 in urban and 1.35 in rural areas. Although I/O ratios of lead were close to 1, lead concentrations were much higher in urban than in rural areas. The I/O ratio of total VOCs was 2.29 in urban and 2.52 in rural areas, with the highest level in urban indoor settings. The I/O ratio of formaldehyde concentrations was higher in rural than in urban areas because the outdoor rural level was much lower than the urban concentration. Since an I/O ratio higher than 1 implies the presence of indoor sources, we concluded that there are many indoor sources in preschools.

Conclusions

We confirmed that pollutants in indoor and urban settings were higher than those in outdoor and rural areas, respectively. Preschool children are expected to spend more time inside preschool facilities and therefore to be more exposed to pollutants. As far as we know, preschool IAQ is different from elementary school or higher school IAQ. Also, they are more vulnerable than higher-grade children. We found that the indoor and urban concentration profiles of the studied pollutants in preschools were higher than those in outdoor and rural areas. We believe that our findings may be useful for understanding the potential health effects of exposure and intervention studies in preschools.  相似文献   
9.
Jung J  Yoon JH  Chung HH  Lee MJ 《Chemosphere》2003,51(9):881-885
The effects of H(2)O(2) and O(3) on the decomposition of trichloroethylene (TCE) and perchloroethylene (PCE) by gamma-rays (gamma-rays) were investigated in this work. The combined gamma-rays/O(3) process showed a synergistic effect and enhanced the removal of TCE and PCE compared with gamma-rays alone, but, the gamma-rays/H(2)O(2) process did not increase the removal. This interesting result was successfully identified by an electron paramagnetic resonance spectroscopy/spin-trapping method that can quantify hydroxyl radicals, which is directly related to the efficiency of TCE and PCE decomposition. For gamma-rays/H(2)O(2) system, there was no difference of hydroxyl radical production between gamma-rays alone and gamma-rays/H(2)O(2). This indicates gamma-rays cannot activate H(2)O(2) to produce hydroxyl radicals and this causes no increase of TCE and PCE removals. To the contrary, the production of hydroxyl radicals was obviously increased in the case of gamma-rays/O(3) process. This suggests additional hydroxyl radicals are produced from the reaction of O(3) with the irradiation products of water such as hydrated electrons, hydrogen atoms, etc. and this accelerates the removal of TCE and PCE.  相似文献   
10.
The amount, location, and form of NAPL in contaminated vadose zones are controlled by the spatial distribution of water saturation and soil permeability, the NAPL spill scenario, water infiltration events, and vapor transport. To evaluate the effects of these processes, we used the three-phase flow simulator STOMP, which includes a new permeability-liquid saturation-capillary pressure (k-S-P) constitutive model. This new constitutive model considers three NAPL forms: free, residual, and trapped. A 2-D vertical cross-section with five stratigraphic layers was assumed, and simulations were performed for seven cases. The conceptual model of the soil heterogeneity was based upon the stratigraphy at the Hanford carbon tetrachloride (CT) spill site. Some cases considered co-disposal of NAPL with large volumes of wastewater, as also occurred at the Hanford CT site. In these cases, the form and location of NAPL were most strongly influenced by high water discharge rates and NAPL evaporation to the atmosphere. In order to investigate the impact of heterogeneity, the hydraulic conductivity within the lower permeability layer was modeled as a realization of a random field having three different classes. For six extreme cases of 100 realizations, the CT mass that reached the water table varied by a factor of two, and was primarily controlled by the degree of lateral connectivity of the low conductivity class within the lowest permeability layer. The grid size at the top boundary had a dramatic impact on NAPL diffusive flux just after the spill event when the NAPL was present near the ground surface. NAPL evaporation with a fine grid spacing at the top boundary decreased CT mass that reached the water table by 74%, compared to the case with a coarse grid spacing, while barometric pumping had a marginal effect for the case of a continuous NAPL spill scenario considered in this work. For low water infiltration rate scenarios, the distribution of water content prior to a NAPL spill event decreased CT mass that reached the water table by 98% and had a significant impact on the formation of trapped NAPL. For all cases simulated, use of the new constitutive model that allows the formation of residual NAPL increased the amount of NAPL retained in the vadose zone. Density-driven advective gas flow from the ground surface controlled vapor migration in strongly anisotropic layers, causing NAPL mass flux to the lower layer to be reduced. These simulations indicate that consideration of the formation of residual and trapped NAPLs and dynamic boundary conditions (e.g., areas, rates, and periods of different NAPL and water discharge and fluctuations of atmospheric pressure) in the context of full three-phase flow are needed, especially for NAPL spill events at the ground surface. In addition, NAPL evaporation, density-driven gas advection, and NAPL vertical movement enhanced by water flow must be considered in order to predict NAPL distribution and migration in the vadose zone.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号