首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   32篇
  免费   0篇
环保管理   3篇
基础理论   7篇
污染及防治   17篇
评价与监测   4篇
社会与环境   1篇
  2019年   1篇
  2018年   2篇
  2016年   1篇
  2013年   8篇
  2012年   2篇
  2011年   2篇
  2010年   3篇
  2008年   1篇
  2006年   3篇
  2004年   2篇
  2001年   1篇
  2000年   3篇
  1993年   1篇
  1991年   1篇
  1988年   1篇
排序方式: 共有32条查询结果,搜索用时 15 毫秒
1.
Introductions of non-native predators often reduce biodiversity and affect natural predator–prey relationships and may increase the abundance of potential disease vectors (e.g., mosquitoes) indirectly through competition or predation cascades. The Santa Monica Mountains (California, U.S.A.), situated in a global biodiversity hotspot, is an area of conservation concern due to climate change, urbanization, and the introduction of non-native species. We examined the effect of non-native crayfish (Procambarus clarkii) on an existing native predator, dragonfly nymphs (Aeshna sp.), and their mosquito larvae (Anopheles sp.) prey. We used laboratory experiments to compare the predation efficiency of both predators, separately and together, and field data on counts of dragonfly nymphs and mosquito larvae sampled from 13 local streams. We predicted a lower predation efficiency of crayfish compared with native dragonfly nymphs and a reduced predation efficiency of dragonfly nymphs in the presence of crayfish. Dragonfly nymphs were an order of magnitude more efficient predators than crayfish, and dragonfly nymph predation efficiency was reduced in the presence of crayfish. Field count data showed that populations of dragonfly nymphs and mosquito larvae were strongly correlated with crayfish presence in streams, such that sites with crayfish tended to have fewer dragonfly nymphs and more mosquito larvae. Under natural conditions, it is likely that crayfish reduce the abundance of dragonfly nymphs and their predation efficiency and thereby, directly and indirectly, lead to higher mosquito populations and a loss of ecosystem services related to disease vector control.  相似文献   
2.
3.
Abstract

Acidic sulfate concentrations were measured in metropolitan Philadelphia during the summers of 1992 and 1993, as part of a continuing effort to characterize particle concentrations in urban environments. Sampling was performed simultaneously at eight sites located within and around metropolitan Philadelphia. Sites were selected based on their population density and on their distance and direction from the city center. Air pollution sampling was conducted every other day during the summer of 1992 and every day during the summer of 1993. All samples were collected for 24-h periods beginning at 9 a.m. (EDT). All acidic sulfate and ammonia samples were collected using modified Harvard-EPA Annular Denuder Systems (HEADS).

In this paper, we examine the spatial variation in acidic sulfate and ammonia concentrations within the metropolitan Philadelphia area. We also identify factors that may influence their variation and develop models to predict their concentrations. Outdoor sulfate (SO4 2?) concentrations were uniform within metropolitan Philadelphia; however, aerosol strong acidity (H+) concentrations varied spatially. This variation generally was independent of wind direction, but was related to local factors, such as the NH3 concentration, population density, and distance from the center of the city. Physico-chemical models, which were developed using data collected during the summer of 1992, were excellent predictors of 24-h and mean summertime H+ concentrations measured during the summer of 1993. Models accounted for 78% of the variation in 24-h H+ levels. Results suggest that a single stationary ambient (SAM) monitor would be sufficient to estimate SO4 2? exposures for populations living in Philadelphia. For H+, however, multiple monitoring sites or models should be used to determine the outdoor H+ exposures of populations living in urban environments, although a single SAM site may provide an excellent index of H+ variation over time.  相似文献   
4.
ABSTRACT

While researchers have linked acute (less than 12-hr) ambient O3, PM25, and CO concentrations to a variety of adverse health effects, few studies have characterized short-term exposures to these air pollutants, in part due to the lack of sensitive, accurate, and precise sampling technologies. In this paper, we present results from the laboratory and field evaluation of several new (or modified) samplers used in the “roll-around” system (RAS), which was developed to measure 1-hr O3, PM25, and CO exposures simultaneously. All the field evaluation data were collected during two sampling seasons: the summer of 1998 and the winter of 1999.

To measure 1-hr O3 exposures, a new active O3 sampler was developed that uses two nitrite-coated filters to measure O3 concentrations. Laboratory chamber tests found that the active O3 sampler performed extremely well, with a collection efficiency of 0.96 that did not vary with temperature or relative humidity (RH). In field collocation comparisons with a reference UV photometric monitor, the active O3 sampler had an effective collection efficiency ranging between 0.92 and 0.96 and a precision for 1-hr measurements ranging between 4 and 6 parts per billion (ppb). The limits of detection (LOD) of this method were 9 ppb-hr for the chamber tests and ~16 ppb-hr for the field comparison tests.

PM2.5 and CO concentrations were measured using modified continuous monitors—the DustTrak and the Langan, respectively. A size-selective inlet and a Nafion dryer were placed upstream of the DustTrak inlet to remove particles with aerodynamic diameters greater than 2.5 um and to dry particles prior to the measurements, respectively. During the field validation tests, the DustTrak consistently reported higher PM2.5 concentrations than those obtained by the collocated 12-hr PM2 5 PEM samples, by approximately a factor of 2. After the DustTrak response was corrected (correction factor of 2.07 in the summer and 2.02 in the winter), measurements obtained using these methods agreed well with R2 values of 0.87 in the summer and 0.81 in the winter. The results showed that the DustTrak can be used along with integrated measurements to measure the temporal and spatial variation in PM2 5 exposures. Finally, during the field validation tests, CO concentrations measured using the Langan were strongly correlated with those obtained using the reference method when the CO levels were above the LOD of the instrument [~1 part per million (ppm)].  相似文献   
5.
While researchers have linked acute (less than 12-hr) ambient O3, PM2.5, and CO concentrations to a variety of adverse health effects, few studies have characterized short-term exposures to these air pollutants, in part due to the lack of sensitive, accurate, and precise sampling technologies. In this paper, we present results from the laboratory and field evaluation of several new (or modified) samplers used in the "roll-around" system (RAS), which was developed to measure 1-hr O3, PM2.5, and CO exposures simultaneously. All the field evaluation data were collected during two sampling seasons: the summer of 1998 and the winter of 1999. To measure 1-hr O3 exposures, a new active O3 sampler was developed that uses two nitrite-coated filters to measure O3 concentrations. Laboratory chamber tests found that the active O3 sampler performed extremely well, with a collection efficiency of 0.96 that did not vary with temperature or relative humidity (RH). In field collocation comparisons with a reference UV photometric monitor, the active O3 sampler had an effective collection efficiency ranging between 0.92 and 0.96 and a precision for 1-hr measurements ranging between 4 and 6 parts per billion (ppb). The limits of detection (LOD) of this method were 9 ppb-hr for the chamber tests and approximtely 16 ppb-hr for the field comparison tests. PM2.5 and CO concentrations were measured using modified continuous monitors--the DustTrak and the Langan, respectively. A size-selective inlet and a Nafion dryer were placed upstream of the DustTrak inlet to remove particles with aerodynamic diameters greater than 2.5 microm and to dry particles prior to the measurements, respectively. During the field validation tests, the DustTrak consistently reported higher PM2.5 concentrations than those obtained by the collocated 12-hr PM2.5 PEM samples, by approximately a factor of 2. After the DustTrak response was corrected (correction factor of 2.07 in the summer and 2.02 in the winter), measurements obtained using these methods agreed well with R2 values of 0.87 in the summer and 0.81 in the winter. The results showed that the DustTrak can be used along with integrated measurements to measure the temporal and spatial variation in PM2.5 exposures. Finally, during the field validation tests, CO concentrations measured using the Langan were strongly correlated with those obtained using the reference method when the CO levels were above the LOD of the instrument [approximately 1 part per million (ppm)].  相似文献   
6.
A conjoint analysis of gut contents and stable C and N isotopes was applied to determine the main food sources and feeding habits of dominant amphipods in an eelgrass bed (Zostera marina) in Gwangyang Bay, Korea. Gut content observations demonstrated that, while Gammaropsis japonicus and Jassa slatteryi are herbivorous, feeding on epiphytes and detritus, Pontogeneia rostrata and Monocorophium acherusicum are omnivorous, feeding on mesozooplankton fragments and detritus. Stable isotope data confirmed that epiphytes, detritus, and mesozooplankton fragments were major food sources for amphipods in the eelgrass bed. Isotopic mixing model calculations clearly showed an interspecific difference in diet composition. A high isotopic dissimilarity between amphipod taxa demonstrated interspecific trophic diversity, reflecting their herbivorous (G. japonicus and J. slatteryi) and omnivorous (P. rostrata and M. acherusicum) feeding habits and confirmed the detrivorous feeding habits of caprellids. Such trophic diversity at interspecific level of the amphipod species indicates that they use different food resources within their microhabitats and play species-specific functional roles as mediators in trophic pathways from producers to higher-level consumers of the eelgrass ecosystem. Finally, our findings suggest that information on the species-specific trophic ecology of amphipods is needed to better understand their potential role in the trophic dynamics and carbon flow of seagrass bed ecosystems.  相似文献   
7.
Measurements of pollutant gases, airborne particulate matter mass and composition, and meteorology have been made at a core site near downtown Atlanta, GA, since August 1998 in support of the Aerosol Research and Inhalation Epidemiology Study (ARIES). This site is one of eight in the Southeastern Aerosol Research and Characterization network. The measurement objective is to provide a long-term, multivariate dataset suitable for investigating statistical associations of respiratory and cardiovascular disease with airborne particulate matter composition, meteorology, and copollutant gases through epidemiologic modeling. Measurements are expected to continue through 2010. Ancillary multiyear measurements at additional sites in the Atlanta metropolitan area and in short-term exposure assessments have been used to estimate the exposure/measurement error associated with using data from a central site to approximate human exposures for the entire area. To date, 13-, 25-, and 53-month air quality datasets have been used in epidemiologic analyses.  相似文献   
8.
Despite strong longitudinal associations between particle personal exposures and ambient concentrations, previous studies have found considerable inter-personal variability in these associations. Factors contributing to this inter-personal variability are important to identify in order to improve our ability to assess particulate exposures for individuals. This paper examines whether ambient, home outdoor and home indoor particle concentrations can be used as proxies of corresponding personal exposures. We explore the strength of the associations between personal, home indoor, home outdoor and central outdoor monitoring site ("ambient site") concentrations of sulfate, fine particle mass (PM(2.5)) and elemental carbon (EC) by season and subject for 25 individuals living in the Boston, MA, USA area. Ambient sulfate concentrations accounted for approximately 70 to 80% of the variability in personal and indoor sulfate levels. Correlations between ambient and personal sulfate, however, varied by subject (0.1-1.0), with associations between personal and outdoor sulfate concentrations generally mirroring personal-ambient associations (median subject-specific correlations of 0.8 to 0.9). Ambient sulfate concentrations are good indicators of personal exposures for individuals living in the Boston area, even though their levels may differ from actual personal exposures. The strong associations for sulfate indicate that ambient concentrations and housing characteristics are the driving factors determining personal sulfate exposures. Ambient PM(2.5) and EC concentrations were more weakly associated with corresponding personal and indoor levels, as compared to sulfate. For EC and PM(2.5), local traffic, indoor sources and/or personal activities can significantly weaken associations with ambient concentrations. Infiltration was shown to impact the ability of ambient concentrations to reflect exposures with higher exposures to particles from ambient sources during summer. In contrast in the winter, lower infiltration can result in a greater contribution of indoor sources to PM(2.5) and EC exposures. Placing EC monitors closer to participants' homes may reduce exposure error in epidemiological studies of traffic-related particles, but this reduction in exposure error may be greater in winter than summer. It should be noted that approximately 20% of the EC data were below the field limit of detection, making it difficult to determine if the weaker associations with the central site for EC were merely a result of methodological limitations.  相似文献   
9.
ABSTRACT

The number of households migrating to agricultural villages has sharply increased in the Republic of Korea (South Korea) since the late 1990s when the Asian economic crisis developed. This study investigates the environmental behaviour and the socio-economic characteristics of urban-rural migrant farming households and provides insights into their significance for rural sustainability in South Korea. The study is based on survey data collected in 2016 from a sample of 166 migrant farming households and 46 native farming households from the Namwon region in South Korea. The migrant farming households are divided into 29 return and 137 non-return farming households. It was found that most non-return migrants are organic farmers, and can be characterised as anti-urban, amenity-pursuing, green, and lifestyle migrants. It is no wonder that they have a strong intent to make their new home an environmentally, socially and economically sustainable place for their children. Thus, appropriate policy measures need to be designed in such a way to facilitate the synergy between the repopulation of rural areas by farming migrants, their uptake of organic farming, their active engagement in community rebuilding, and regional economic development.  相似文献   
10.
Hourly concentrations of ambient fine particle sulfate and carbonaceous aerosols (elemental carbon [EC], organic carbon [OC], and black carbon [BC]) were measured at the Harvard-U.S. Environmental Protection Agency Supersite in Boston, MA, between January 2007 and October 2008. These hourly concentrations were compared with those made using integrated filter-based measurements over 6-day or 24-hr periods. For sulfate, the two measurement methods showed good agreement. Semicontinuous measurements of EC and OC also agreed (but not as well as for sulfate) with those obtained using 24-hr integrated filter-based and optical BC reference methods. During the study period, 24-hr PM2.5 (particulate matter [PM] < or = 2.5 microm in aerodynamic diameter) concentrations ranged from 1.4 to 37.6 microg/m3, with an average of 9.3 microg/m3. Sulfate as the equivalent of ammonium sulfate accounted for 39.1% of the PM2.5 mass, whereas EC and OC accounted for 4.2 and 35.2%, respectively. Hourly sulfate concentrations showed no distinct diurnal pattern, whereas hourly EC and BC concentrations peaked during the morning rush hour between 7:00 and 9:00 a.m. OC concentrations also exhibited nonpronounced, small peaks during the day, most likely related to traffic, secondary organic aerosol, and local sources, respectively.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号