首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   174篇
  免费   2篇
  国内免费   9篇
安全科学   15篇
废物处理   32篇
环保管理   21篇
综合类   23篇
基础理论   24篇
污染及防治   59篇
评价与监测   5篇
社会与环境   6篇
  2023年   3篇
  2022年   1篇
  2021年   1篇
  2019年   5篇
  2018年   9篇
  2017年   7篇
  2016年   10篇
  2015年   7篇
  2014年   6篇
  2013年   17篇
  2012年   11篇
  2011年   9篇
  2010年   13篇
  2009年   14篇
  2008年   22篇
  2007年   13篇
  2006年   8篇
  2005年   3篇
  2004年   9篇
  2003年   5篇
  2002年   6篇
  2000年   3篇
  1994年   1篇
  1991年   1篇
  1990年   1篇
排序方式: 共有185条查询结果,搜索用时 46 毫秒
1.
Diadromous fish often enter freshwater directly from seawater via fish ladders or channels built in estuarine dams. The oxygen consumption rates (OCR) of glass eel, Anguilla japonica, were determined using an automatic intermittent flow respirometer under various salinity and temperature regimes to physiologically explain this direct movement. The endogenous rhythm of the OCR in wild glass eels, freshly collected from estuaries, was nearly synchronous with the tidal pattern at the estuarine collection site. When the salinity was changed from 20 psu (12°C) at a constant temperature to that of freshwater, the OCR of the glass eels decreased by 21.6±7.0% (mean ± SD) (P<0.05), showing a dampened rhythm for about 48 h. After this period of impediment, the glass eels resumed normal metabolic activity. Direct migration from seawater to freshwater under constant temperature would result in a severe physiological stress for these glass eels for about two days. When the glass eels were exposed to a cyclic change in water temperature of 2°C 26 h−1, as they encounter in estuaries, and then were introduced to freshwater abruptly, the OCR rhythm corresponded to the cyclic changes in water temperature after exposure to freshwater. Under these conditions, the mean OCR of the glass eels had a small difference before and after exposure to freshwater. These data explained how glass eels can directly move from sea water into the freshwater without any apparent metabolic stress in the estuaries showing cyclic change in water temperature (Δt=2°C).  相似文献   
2.
This study was a basic one to explore how much the aerodynamic characteristics of wind blade improve. The extent of improvement according to the shapes of groove placed on the surface of airfoil (NACA0015) was analyzed through computational analysis. A commercial computational fluid dynamics (CFD) code, the ANSYS Fluent 13, was used in this study. In this study, regarding with the positions and shapes of groove, the end of groove was placed at a certain distance (length, l) from both the front and back of separation starting point, the depth and the width were designated as h and d respectively. Analysis was conducted at the 7° angle of attack under the following conditions; the thickness (δ) of boundary layer to the depth (h) of groove ratio (h/δ) 0.6–1.0, the depth (h) of groove to the width (d) of groove ratio (h/d) 0.1–1.4, and the length (l) between the end of groove and separation point to the thickness (δ) of boundary layer ratio (l/δ) ?0.5–0.5. Among these conditions, the best improvement of lift to drag ratio, standing at 15.3%, was under h/δ = 1.0, h/d = 0.12, and l/δ = –0.5 (7° AOA, Re = 360k). In addition, throughout the range of angle of attack, 2–14°, lift to drag ratio improved by 0.8%, 5.1%, 3.2%, and 1.8% each when Reynolds numbers were 280k, 360k, 450k, and 530k. It is also confirmed that the shape of groove contributed to recovering velocity around airfoil wall and the lift to drag ratio improvements by groove were maintained at the given range of Reynolds number and around the angle of attack, 7°.  相似文献   
3.
This paper discusses about the quantitative effect of windbreak fences on wind velocity in the reclaimed land at Saemangeum in South Korea. Windbreak fences were constructed in the reclaimed land to reduce the wind velocity to prevent the generation and diffusion of dust. However, up to this time, no in-depth studies were conducted to quantitatively measure the effect of the windbreak fences on wind velocity thus an optimum windbreak structure is not yet determined. Using CFD simulations, the effects of fence porosity, fence height, and the distance between the adjacent fences were investigated. A wind tunnel experiment was initially conducted and data gathered were used to develop the CFD models. From the experiments and CFD simulations, the overall percentage difference of the measured velocities was 7.20% which is generally acceptable to establishing the reliability of the CFD models. The reduction effect on wind velocity was measured in between the adjacent fences up to a height of 0.6 m from the ground surface. In terms of porosity ( = 0, 0.2, 0.4, 0.6), 0.2 was found to be the optimum value. Conversely, the effect of fence height (0.6, 0.8 and 1.0 m) showed no significant difference; therefore, 0.6 m height is recommended. In addition, the reduction effect of distance between the adjacent fences (2, 4 and 6 m) on wind velocity having a 0.2 porosity has decreased to about 75% regardless of the distance. In the case of the reclaimed land in Saemangeum, a decrease of 75% can prevent the generation and diffusion of dusts. However, the source of dusts is very large. Therefore, constructing an array of windbreak with 6 m distance between them is deemed necessary.  相似文献   
4.
A pilot study was conducted to estimate fungal spore penetration for wall service outlets subjected to a constant air pressure. During the laboratory experiment, a wall chamber was fabricated, and telephone, electrical, and cable service outlets were installed. Penicillium chrysogenum spores were aerosolized into the chamber that was held under pressure. Spores that penetrated the outlets were funneled into an impinger for microscopic enumeration. Thirty trials were conducted for each of the five outlets (N?= 150), and the wall chamber was decontaminated between trials. Results of an analysis of variance suggest wall service outlets allow spore penetration. The penetration factor for the telephone outlet was significantly greater than all other outlets (p?< 0.05), and there was no difference in penetration between electrical outlets with and without plugs. Penetration factor differences were attributed to air leakage rates across the outlets. Due to the experimental design and equipment limitations, further research is needed to support these findings.  相似文献   
5.
Seo J  Kato S  Tatsuma T  Chino S  Takada K  Notsu H 《Chemosphere》2008,72(9):1286-1291
A fungal biosensor plate was applied to assessment of the harmfulness of air polluted by formaldehyde. Alternariaalternata, Eurotiumherbariorum and Aspergilluspenicillioides were used as fungal species. Fungal mycelium length and optical transparency of the biosensor plate were employed as indices of the fungal growth. Formaldehyde in air was detected on the basis of growth inhibition, reflected by suppression of the growth indices. Dynamic range of the measurement was 700-4000 microg m(-3) or broader. Eurotiumherbariorum and Aspergilluspenicillioides were the most suitable fungal species to formaldehyde sensing based on the mycelium length and that based on the transparency, respectively.  相似文献   
6.
The mixing characteristics of a passive scalar in the turbulent flow of a selective catalytic reduction process were numerically and experimentally investigated, focusing especially on an injection nozzle with multiple holes for the reducing agent. The multihole injection nozzle studied has six holes that are perpendicular to the ambient flue gas flow and are located near the tip of the nozzle. Large eddy simulation was applied to the turbulent flow and mixing fields to elucidate the mixing mechanism of the proposed nozzle compared with the single-hole nozzle that is commonly used in the conventional selective catalytic reduction process. From the results, there exist broader regions of higher turbulent intensities for the multihole nozzle than for the conventional single-hole nozzle. These regions are well matched with the positions of high vorticity in the near upstream region of the jet flow issuing from the multiple holes of the nozzle. Consequently, the high turbulent intensities and vorticity magnitudes lead to intensified mixing between the flue gas and the reducing agent. Hence, the most suitable molar ratio between NOx and the reducing agent for the catalytic reaction can be easily obtained within a shorter physical mixing length as a result of the enhanced scalar mixing. Finally, the numerical results were applied to a trial design version of a multihole nozzle, and this nozzle was experimentally tested to confirm its mixing performance.  相似文献   
7.
Gasification experiments for sawdust were conducted using a fixed bed reactor at 900 °C by varying the secondary oxidant injection ratio to determine the optimal conditions for tar removal along with the enhancement of gasification efficiency. Secondary oxidant was injected as an oxidant at the top zone of the gasifier in varying ratios of 10–30% of the total amount of oxidant. This method was based on the primary method of tar removal and gasification efficiency improvement by thermal cracking of tar. Various gasification performance parameters were evaluated and tar content was estimated by measuring the fluctuation of weight of the activated carbon filter. The results showed that the concentration of tar in the producer gas decreased by injecting the secondary oxidant, even though syngas yield decreased. The recycling potential of the char produced in the gasification experiments was also assessed with the purpose of utilizing char as an adsorbent by determining its surface area and pore volume. The results demonstrated that the char produced from the gasification experiment had similar quality to that of the activated carbon used in this experiment.  相似文献   
8.
In this paper, emission and distribution behavior of six heavy metals (As, Cd, Cr, Ni, Pb, and Hg), particulate matter and mass distribution of mercury within the different streams of a fluidized bed sewage sludge incinerator are presented. At the inlet of air pollution control devices (APCDs); Cd, Cr, Ni and Pb were mainly enriched in coarse particles; comparatively As content was higher in fine particles (<PM2.5). The concentration of heavy metals in total particulate matter and PM2.5, at the inlet of APCDs, were in the order of Cr > Ni > Pb > As > Cd. Mercury was almost always distributed in flue gas. Metals, other than mercury, were efficiently removed in APCDs and their concentrations in bottom ash, with fly ash being higher, whereas for that in wastewater, then waste sand was lesser. Overall mercury removal efficiency of APCDs was 98.6 %. More than 83.3 % of mercury was speciated into oxidized form at the inlet of APCDs, attributed by higher chlorine content in sludge. Mercury was mainly distributed in wastewater (78.4 %), wastewater from a spray dry reactor (16.8 %), fly ash in a hopper (3.4 %) and flue gas (1.4 %). This result is one of the first for data to be obtained; more experiments are required to control emission from such sources.  相似文献   
9.
A comparative study on Fe/Al, Fe/Al/Cu, and Fe/Al/Ni catalysts in high-temperature water–gas shift reaction (HT–WGS) using simulated waste-derived synthesis gas has been carried out. The metal oxide (Cu and Ni) and aluminum incorporated Fe catalysts were designed to get highly active HT–WGS catalysts. Despite the high CO concentration in the simulated waste-derived synthesis gas, Fe/Al/Cu catalyst exhibited the highest CO conversion (84 %) and 100 % selectivity to CO2 at a very high gas hourly space velocity (GHSV) of 40,057 h?1. The outstanding catalytic performance is mainly due to easier reducibility, the synergy effect of Cu and Al, and the stability of the magnetite.  相似文献   
10.
A simple and highly effective stabilization/solidification (S/S) technology of elemental mercury using only sulfur with paraffin is introduced. First, elemental mercury is mixed with an excess of sulfur powder and heated to 60 degrees C for 30 min until elemental mercury is converted into mercuric sulfide (HgS black, metacinnabar) (Step 1). Then, metacinnabar with additional sulfur is poured into liquid paraffin (Step 2). Finally, the mixture is melted at 140 degrees C and settles to the bottom of the vessel where it cools and solidifies under the layer of liquid paraffin (Step 3). The proposed S/S method with sodium sulfide nonahydrate (Na2S x 9H2O) as an additive is also tested for comparison. The average toxicity characteristic leaching procedure test values are 6.72 microg/L (no additive) and 3.18 microg/L (with additive). Theses concentrations are well below the Universal Treatment Standard (25 microg/L). Effective diffusion coefficient evaluated from accelerated leach test and average headspace concentration of Hg vapor after 18 hr are 3.62 x 10(-15) cm2/sec, 0.55 mg/m3 (no additive) and 5.86 x 10(-13) cm2/sec, 0.25 mg/m3 (with additive).  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号