首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   14篇
  免费   0篇
废物处理   1篇
综合类   5篇
基础理论   4篇
污染及防治   3篇
评价与监测   1篇
  2020年   1篇
  2016年   1篇
  2011年   2篇
  2010年   1篇
  2006年   1篇
  2002年   1篇
  1994年   1篇
  1984年   1篇
  1982年   2篇
  1979年   1篇
  1965年   1篇
  1960年   1篇
排序方式: 共有14条查询结果,搜索用时 421 毫秒
1.
2.
The landscape architecture profession is a source of creative thinking and planning which is relatively untapped within the mining industry in the United States of America. The landscape architect has been active in European operations for years as indicated by the four examples presented. The landscape architect can provide an important interface with mine design and engineering and environmental affairs. To initiate this interface within the United States, and increase its effectiveness, six objectives are presented and discussed.  相似文献   
3.
4.
In the present work, microwave joining of stainless steel (SS-316) to mild steel (MS) in bulk form has been successfully carried out using a multimode applicator at 2.45 GHz and 900 W. Principles of hybrid heating were employed using a susceptor medium so as to initiate coupling of microwave with the metals. A nickel based metallic powder was used as a sandwich layer between the bulk pieces. Samples were exposed to microwave radiation in atmospheric conditions. Resulting joints were characterized using field emission scanning electron microscope (FESEM), X-ray diffractometer, microhardness tester and universal testing machine. Microstructure study showed the faying surfaces were well fused and got bonded on either side of the base material. Formation of cementite and metallic carbides were evidenced. The average observed Vickers’ microhardness of core of the joint area was observed to be 133 Hv with 0.58% porosity. The ultimate tensile strength of the joint was found to be 346.6 MPa with percentage elongation of 13.58%. Fractography reveals that the joints failed due to both shearing of the brittle carbides and oxides as well as due to plastic flow of the ductile matrix under tensile loading.  相似文献   
5.
In this study, strains that are capable of bioaccumulating Cr(VI) were isolated from treated tannery effluent of a common effluent treatment plant. The Cr(VI) concentration in this treated effluent was 0.96 mg/l, much above the statutory limit of 0.1 mg/l for discharge of industrial effluents into inland surface waters in India. In addition to the bioaccumulation, biosorption capabilities of living and dead cells were analysed. Two strains, identified as Bacillus circulans and Bacillus megaterium were able to bioaccumulate 34.5 and 32.0 mg Cr/g dry weight, respectively and brought the residual concentration of Cr(VI) to the permissible limit in 24 h when the initial concentration was 50 mg Cr(VI)/l. Our experimental design accounts for initial as well as final residual concentration of heavy metal while selecting heavy metal accumulating strains during batch studies. Biosorption of Cr(VI) was shown by B. megaterium and an another strain, B. coagulans. Living and dead cells of B. coagulans biosorbed 23.8 and 39.9 mg Cr/g dry weight, respectively, whereas, 15.7 and 30.7 mg Cr/g dry weight was biosorbed by living and dead cells of B. megaterium, respectively. Biosorption by the dead cells was higher than the living cells. This was due to prior pH conditioning (pH 2.5 with deionized water acidified with H2SO4) of the dead cells.  相似文献   
6.
The efficacy of Common Effluent Treatment Plant (CETP) based on activated sludge process employed for treatment of tannery effluent was analyzed for the efficiency to reduce chromium and other contaminants. Physico-chemical parameters of treated effluent were found within permissible levels of statutory limits. A significant reduction in COD and BOD levels were achieved during the course of treatment in CETP. A reduction of 98.46%, 87.5%, and 96.15% in bacterial counts especially in pathogens like Escherichia coli, Vibrio spp., and Pseudomonas spp. were observed after treatment. Pathogens were not detected in the dried sludge. Complete elimination of fecal streptococci was observed in treated effluent. Around 10.8% of microbial isolates from the effluent showed ability to reduce chromate >90%. In treated effluent chromium level was 5.48 mg/L, which exceeds the statutory limit of Indian standards. Cleaner production options to reduce chromium levels before discharging into water bodies is discussed.  相似文献   
7.
8.
Prenatal diagnosis choices were reviewed in 473 women who presented for genetic counselling prior to 11 weeks' gestation for the indication of advanced maternal age. Group A consisted of 336 patients who were unaware of a possible association between chorionic villus sampling (CVS) and limb defects. Group B consisted of 137 patients who were provided this information. Fifty-one per cent of patients in group A and 45 per cent of patients in group B chose CVS. This difference was not significant by χ2 analysis (P = 0·7). Patterns of prenatal diagnosis procedure utilization from 1987 to 1992 revealed a significant reduction in CVS utilization accompanied by a corresponding increase in amniocentesis after the association between CVS and limb defects was publicized. Referrals for CVS counselling also significantly declined. However, acceptance rates did not change for those patients who received genetic counselling. First-trimester genetic counselling, including a discussion regarding a possible association between CVS and limb defects, helps patients make informed decisions concerning prenatal diagnosis options, and, in our population, resulted in no change in CVS acceptance rates.  相似文献   
9.
While larger mineral resource development projects offer new jobs and provide a stimulus to the economy of the area where they are sited, they may also pose problems in rural areas associated with rapid population growth. The purpose of an impact management programme is to anticipate and alleviate project effects that are generally perceived as undesirable and to enhance effects that are beneficial to site area communities. While the effective management of project effects is the end towards which all impact assessment efforts are directed, an integrated approach to impact management has been notably lacking. This paper suggests a systems framework for meeting this need by: (1) reviewing the need for impact management efforts; (2) discussing the objectives of, and considerations in, designing impact management programmes; (3) presenting a conceptual framework for, and key components of, such a programme; and (4) suggesting an approach for implementing such a system as an integral part of the project development process.  相似文献   
10.
Deer movements around surface coal mines were investigated in Preston Country, West Virginia, USA. Seventy-two deer crossings were counted on 29 surface mines with only 8% found on highwalls with more than 20% rock or stone. Thus, although slope was important, the percentage of dirt on the highwall determined use as a crossing location for deer. The average distance between all deer crossing was 209.7 m but the distance between the end of the highwall and the nearest highwall crossing was 248.7 m indicating reluctance of deer to cross mines when they could walk around them. Winter snow track counts showed fewer deer within 90 m of the top edge of the highwall. Four land bridges traversed the highwall and were heavily utilized by deer, especially in March, April, May, October and November. The surface mine bench was used as a fawn bedding area, but little feeding occurred on this portion of the mine.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号