The body of information of this paper is directed to those individuals charged with selecting a process to control atmospheric sulfur emissions from Claus plants serving refineries, gas processing installations, and chemical plants. The TGT process developed by the French Petroleum Institute (IFP) is an extension of the Claus reaction itself in the liquid phase. Mixed H2S and SO2 in tail gas from Claus units is fed to a packed tower in which a solution of proprietary catalyst in a high BP polyglycol circulates countercurrent to the gas flow. The mixed gases react with the catalyst to form a complex, which in turn reacts with more gases to produce elemental sulfur. Reaction temperature keeps the sulfur above its melting point. Product accumulates in the boot of the tower and is drawn off continuously through a seal leg.

The IFP TGT process is simple in design and units have simple construction, characterized by use of low carbon steel and the use of very few pieces of equipment. Of all processes used today to take effluent sulfur values down to 1000 ppm SO2 after incineration, the IFP TGT process requires the least capital investment and the lowest operating costs. Twenty-six full scale plants are operating or under design or construction: nine each in the U.S. and Japan, five in the U.S.S.R. and Poland, two in western Europe and one in Canada. Capacities of the Claus plants served range from 45 to 800 Lt/d sulfur.  相似文献   