首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   31篇
  免费   0篇
废物处理   2篇
综合类   8篇
污染及防治   17篇
评价与监测   4篇
  2022年   1篇
  2017年   2篇
  2016年   1篇
  2014年   3篇
  2012年   5篇
  2011年   3篇
  2010年   2篇
  2009年   2篇
  2008年   3篇
  2007年   3篇
  2006年   1篇
  2005年   1篇
  2003年   2篇
  2002年   1篇
  2000年   1篇
排序方式: 共有31条查询结果,搜索用时 15 毫秒
1.
The aim of this study was to analyse the relationship between the distribution of hay-fever patients in the city of Córdoba, south-western Iberian Peninsula, and the specific atmospheric biological content originating from local sources. Four different districts were established in the metropolitan area of the city, according to vegetational and urbanistic characteristics. Air samples were taken in each area using portable Hirst-type samplers (Lanzoni VPPS 1000) and the spectrum of biological content was defined. Patients attending the Allergy Unit at Córdoba Teaching Hospital in 2000 with allergic rhinitis and/or asthma, and displaying a positive reaction to aeroallergen extracts, were distributed within the areas as a function of their district of residence. Aerobiological results revealed differences in pollen content between areas, in terms of both quantity and number of pollen types recorded. These differences were largely due to proximity to rural areas, prevalence of pollen from typically urban species and the possible effect of urban architecture as a barrier to the dispersal/ concentration of particles and other pollutants. Patients were not uniformly distributed within the city. The majority lived in districts in which pollen from rural species was mixed with pollen from ornamentals. Patients living in typically urban districts displayed a higher prevalence of allergy to pollen from ornamentals. It is concluded that a high degree of exposure to the same environment may influence the development of sensitisation to the particular pollen load associated with that area.  相似文献   
2.
The distribution of polycyclic aromatic hydrocarbons was determined in surface sediments collected at 36 stations along the Spanish Northern continental shelf in March and September 2003, and February 2005. Concentrations of PAHs (Σ13 parent components) were in the range of 22-47528 μg/kg dw, the highest values corresponding to coastal urban-industrial hotspots and decreasing offshore. Sediment quality guidelines (SQGs) showed that concentrations of total PAHs were below the threshold effect level (TEC) in 27 stations (81%) and above in 7, two of which (Gijon and Bilbao) were above the probable effect concentration (PEC). The detailed study of diagnostic ratios suggested a rather uniform mixture of petrogenic and pyrolytic PAH sources along the continental shelf, with a slight decrease of the latter moving westwards and offshore. In order to assess the incidence of sediment sampling on the variability of the results, selected stations were also monitored in February and September 2004 and September 2005. The average field variance of the values obtained for each station was 31% that decreased to 23% when the values were normalized to TOC.  相似文献   
3.
The recovery and utilization of recovered paper have increased over past decades all over the world due to economic, environmental, and social issues. However, it is well known that an extended recovered paper collection is detrimental to its quality, either by the exploitation of lower quality sources such as households, or the spreading of commingled systems instead of selective collection systems. The influence of these two factors was assessed by analyzing the quality of different recovered paper grades used as raw material in a mill located in Madrid (Spain) producing newsprint and light weight coated paper from recovered paper. Part 1 of the paper deals with the impact of increased collection rates on the quality of recovered paper and Part 2 with the use of commingled collection systems. Results of Part 1 show that increased collection rates have a large impact on the quality of the recovered paper. The quality, measured as total unusable material and moisture contents, had deteriorated very rapidly in only 4 years (2005–2008) as a consequence of increased collection rates. Collection rates increased in Spain from 58.5% to 68.6% during this period, resulting in more than 50% increase of total unusable material and 25% of moisture content. The downgrading of the quality of recovered paper is one of the major threats for extending the current limits of paper recycling. Therefore, future challenge is to increase its availability but maintaining its quality.  相似文献   
4.
The follow-up of a cohort of adults from 29 European centers of the former European Community Respiratory Health Survey (ECRHS) I (1989-1992) will examine the long-term effects of exposure to ambient air pollution on the incidence, course, and prognosis of respiratory diseases, in particular asthma and decline in lung function. The purpose of this article is to describe the methodology and the European-wide quality control program for the collection of particles with 50% cut-off size of 2.5 microm aerodynamic diameter (PM2.5) in the ECRHS II and to present the PM2.5 results from the winter period 2000-2001. Because PM2.5 is not routinely monitored in Europe, we measured PM2.5 mass concentrations in 21 participating centers to estimate background exposure in these cities. A standardized protocol was developed using identical equipment in each center (U.S. Environmental Protection Agency Well Impactor Ninety-Six [WINS] and PQ167 from BGI, Inc.). Filters were weighed in a single central laboratory. Sampling was conducted for 7 days per month for a year. Winter mean PM2.5 mass concentrations (November 2000-February 2001) varied substantially, with Iceland reporting the lowest value (5 microg/m3) and northern Italy the highest (69 microg/m3). A standardized procedure appropriate for PM2.5 exposure assessment in a multicenter study was developed. We expect ECRHS II to have sufficient variation in exposure to assess long-term effects of air pollution in this cohort. Any bias caused by variation in the characteristics of the chosen monitoring location (e.g., proximity to traffic sources) will be addressed in later analyses. Given the homogenous spatial distribution of PM2.5, however, concentrations measured near traffic are not expected to differ substantially from those measured at urban background sites.  相似文献   
5.
6.
A new type of directional passive air sampler (DPAS) is described for collecting particulate matter (PM) in ambient air. The prototype sampler has a non-rotating circular sampling tray that is divided into covered angular channels, whose ends are open to winds from sectors covering the surrounding 360°. Wind-blown PM from different directions enters relevant wind-facing channels, and is retained there in collecting pools containing various sampling media. Information on source direction and type can be obtained by examining the distribution of PM between channels. Wind tunnel tests show that external wind velocities are at least halved over an extended area of the collecting pools, encouraging PM to settle from the air stream. Internal and external wind velocities are well-correlated over an external velocity range of 2.0-10.0 m s?1, which suggests it may be possible to relate collected amounts of PM simply to ambient concentrations and wind velocities. Measurements of internal wind velocities in different channels show that velocities decrease from the upwind channel round to the downwind channel, so that the sampler effectively resolves wind directions. Computational fluid dynamics (CFD) analyses were performed on a computer-generated model of the sampler for a range of external wind velocities; the results of these analyses were consistent with those from the wind tunnel. Further wind tunnel tests were undertaken using different artificial particulates in order to assess the collection performance of the sampler in practice. These tests confirmed that the sampler can resolve the directions of sources, by collecting particulates preferentially in source-facing channels.  相似文献   
7.
Chemical compounds of the foraging recruitment pheromone in bumblebees   总被引:2,自引:0,他引:2  
When the frenzied and irregular food-recruitment dances of bumblebees were first discovered, it was thought that they might represent an evolutionary prototype to the honeybee waggle dance. It later emerged that the primary function of the bumblebee dance was the distribution of an alerting pheromone. Here, we identify the chemical compounds of the bumblebee recruitment pheromone and their behaviour effects. The presence of two monoterpenes and one sesquiterpene (eucalyptol, ocimene and farnesol) in the nest airspace and in the tergal glands increases strongly during foraging. Of these, eucalyptol has the strongest recruitment effect when a bee nest is experimentally exposed to it. Since honeybees use terpenes for marking food sources rather than recruiting foragers inside the nest, this suggests independent evolutionary roots of food recruitment in these two groups of bees.  相似文献   
8.
9.
10.
A survey to estimate the polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzofurans (PCDFs) emissions of Spanish hot dip galvanising sector was carried out during 2002. This investigation is the first presenting Spanish experimental data related to this industrial sector. Three different matrices: flue gas, ash and filter dust were tested to quantify the PCDD/Fs generated during the galvanising process. The organic source of PCDD/F formation could be from the insufficient degreasing o from inhibitors or additives used in the pickling steps such as quinoline, isoquinoline, 8-methylquinoline or polyether phosphoric acid. Low levels PCDD/Fs were achieved in air emissions when air control devices are used. On the contrary, filter dusts are highly contaminated; indicating that the absence of air control devices would increase the risk of fugitive emissions. Homologue profiles and Principal Component Analysis demonstrate there are differences in the formation mechanisms in the bath zone (ashes) compared to the stack location (filter dusts and air emissions), related to the de novo synthesis and reaction time. The annual PCDD/F emission to the atmosphere for this sector during 2002 has been estimated in 0.023g I-TEQ. The emission factor of plants with air control devices has been calculated at 0.030microg I-TEQ/ton of galvanised steel.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号