首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   9篇
  免费   0篇
废物处理   2篇
污染及防治   4篇
评价与监测   1篇
社会与环境   1篇
灾害及防治   1篇
  2021年   1篇
  2013年   1篇
  2011年   2篇
  2008年   1篇
  2005年   1篇
  2000年   1篇
  1999年   1篇
  1983年   1篇
排序方式: 共有9条查询结果,搜索用时 15 毫秒
1
1.
Using the closed-can technique, radon exhalation rate measurements have been carried out for shale and coal samples collected from various mines located in the Chakwal and Makarwal areas of Pakistan. For the two areas, the measured average values of the exhalation rates from shale are 1.45±0.13 and 0.67±0.25 Bq m−2 h−1 and for coal are 1.0±0.03 and 0.65±0.32 Bq m−2 h−1, respectively. These values are much lower than the measured exhalation rates from alum-shale-based Nordic concrete which has values in the 50–200 Bq m−2 h−1 range. The lower values of the measured exhalation rates from the shale and coal deposits in the Chakwal and Makarwal areas are indicative of their lower uranium contents and mine workers in these areas do not face any abnormal health hazard due to radon since the exhalation rates have been found to be on the low side.  相似文献   
2.
3.
Determinations of PCB were carried out as part of a project aimed at developing cleanup methods for PCB-containing elastic sealant used in outdoor joints between concrete blocks. The goals of the project were to develop methods, which minimise the spread of PCB to the outdoor environment and to indoor air, and which keep the PCB levels as low as reasonably possible in the workplace environment whilst removing the elastic sealant. The following PCB determinations were carried out: (1) concentration in the elastic sealant; (2) concentration in the concrete close to the sealant; (3) concentration in soil; (4) concentration in the indoor air; and (5) concentration in the air in the workplace environment. The cleanup process consisted of a number of different steps: (1) cutting the elastic sealant with an oscillating knife; (2) grinding the concrete with a mechanical machine; (3) sawing the concrete with a mechanical saw and (4) cutting the concrete with a mechanical chisel. In all these different steps a high capacity vacuum cleaner connected to the machines was used. The elastic sealant contained 4.7 to 8.1% total PCB of a technical product with a composition most similar to Clophene A40. The concrete close to the sealant (first 2 mm) contained 0.12 and 1.7% total PCB at two different places. The pattern of the PCB in the concrete resembled that of the sealant. PCB concentrations in the soil from the ground close to the building were 0.1 and 0.3 ppm at two different places before the remedial action. The source of the PCB in the soil is most likely the sealant as the PCB pattern is similar for the two materials. The PCB levels in the workplace air at the beginning of the project, when the techniques were not fully developed, were generally above the occupational exposure limit of 10 micrograms m-3 (up to 120 micrograms m-3). Later when the techniques were optimised to better take care of dust and gases produced during the cutting and grinding etc., the levels were below or close to 10 micrograms m-3. The pattern of the PCB in the workplace air was different from that of the sealant and contained higher levels of lighter components. The PCB concentrations in the indoor air were measured before and during the remedial process. The levels were around 600 ng m-3 and there was no significant increase during the removal of the sealant. The PCB level after the remedial action will be measured later. The pattern of the PCB in the indoor air was different from that of the sealant as well as from that of the workplace air. Higher levels of the lighter PCB were present indoors compared to the composition in both workplace air and in sealant. Extracts of PCB were analysed by GC-MS with a SIM method (selected ion monitoring). Standard procedures were used for extraction of solid materials. For the air samples an OVS tube was used with XAD-2 as adsorbent. The filter and adsorbent were extracted with toluene. This work shows that it is important to perform remedial action of PCB-containing elastic sealant as: (1) there is a spread of PCB to the indoor air giving high enough concentrations to make this the main PCB load on humans living in the apartments studied in this project; (2) large amounts are spread to the soil from these sealants; and (3) many of the PCB-containing elastic sealants used need to be changed from a functional perspective.  相似文献   
4.
In the developing world, the vast majority of people rely on solid biomass fuels for cooking and heating which results in poor indoor air quality. The present study determined indoor air quality in some rural and urban areas of Pakistan. Measurements were made of particulate mass (PM10, PM2.5 and PM1), number concentration and bioaerosols in different micro environments. PM10 concentrations of up to 8,555 μg/m3 were observed inside the kitchens where biofuels were used as energy source. Cleaning and smoking was identified as a major source of indoor particulate pollution and concentrations of more than more than 2,000 μg/m3 were recorded in the living room during these activities. Indoor number concentrations in Lahore were typically greater than those observed outdoors in European cites. At a rural site the highest Colony Forming Units (CFUs) were in the 0.5 μm–2 μm size fraction, while at the urban location CFUs were dominant for 2 μm–16 μm. It was observed that CFUs(Colony Forming Units) counts were higher inside living rooms than kitchens. It is important to note that women and children were exposed to extremely high levels of particulates during cooking. Overall, indoor air quality in Pakistan was poor and there is a dire need to take a serious step to combat with it.  相似文献   
5.
Abstract

Recent regulations have required reductions in emissions of nitrogen oxides (NOx) from electric utility boilers. To comply with these regulatory requirements, it is increasingly important to implement state-of-the-art NOx control technologies on coal-fired utility boilers. This paper reviews NOx control options for these boilers. It discusses the established commercial primary and secondary control technologies and examines what is being done to use them more effectively. Furthermore, the paper discusses recent developments in NOx controls. The popular primary control technologies in use in the United States are low-NOx burners and overfire air. Data reflect that average NOx reductions for specific primary controls have ranged from 35% to 63% from 1995 emissions levels. The secondary NOx control technologies applied on U.S. coal-fired utility boilers include reburning, selective noncatalytic reduction (SNCR), and selective catalytic reduction (SCR). Thirty-six U.S. coal-fired utility boilers have installed SNCR, and reported NOx reductions achieved at these applications ranged from 15% to 66%. Recently, SCR has been installed at >150 U.S. coal-fired utility boilers. Data on the performance of 20 SCR systems operating in the United States with low-NOx emissions reflect that in 2003, these units achieved NOx emission rates between 0.04 and 0.07 lb/106 Btu.  相似文献   
6.
Environmental Science and Pollution Research - Energy is an essential parameter for the economic growth and sustainable development of any country. Due to the rapid increase in energy demand,...  相似文献   
7.
In this paper cellulose nanocrystals were prepared by treating microcrystalline cellulose with 1-butyl-3-methylimidazolium hydrogen sulphate ionic liquid. Cellulose nanocrystals, after separation from ionic liquid, were characterized by X-ray diffraction (XRD), Fourier transform infrared (FTIR), Field emission scanning electron microscopy (FESEM) Transmission Electron Microscope (TEM) and Thermogravimetric analysis. XRD results showed no changes in type of cellulose after the treatment with ionic liquid, however, high crystallinity index was observed in the ionic liquid treated sample. Cellulose nanocrystals, having length around 50–300 nm and diameter around 14–22 nm were observed in the ionic liquid treated sample under FESEM and TEM, and similar patterns of peaks as that of microcrystalline cellulose were observed for cellulose nanocrystals in the FTIR spectra. The thermal stability of the cellulose nanocrystals was measured low as compare to microcrystalline cellulose.  相似文献   
8.
The present investigation determined the effects of epibrassinolide (EBL) on the levels of indole-3-acetic acid (IAA), abscisic acid (ABA), and polyamine (PA) and antioxidant potential of 7-d old Raphanus sativus L. cv. ‘Pusa chetki’ seedlings grown under Cr (VI) metal stress. Reduced titers of free (0.767 μg g−1 FW) and bound (0.545 μg g−1 FW) IAA in Cr (VI) stressed seedlings were observed over untreated control. Supplementations of EBL to Cr (VI) stressed seedlings were able to enhance both free (2.14-5.68 μg g−1 FW) and bound IAA (2.45-7.78 μg g−1 FW) concentrations in comparison to Cr (VI) metal treatment alone. Significant rise in free (13.49 μg g−1 FW) and bound (12.17 μg g−1 FW) ABA contents were noticed for Cr (VI) stressed seedlings when compared to untreated control. No significant increase in ABA contents were recorded for Cr (VI) stressed seedlings upon supplementation with EBL over Cr (VI) treatment alone. A significant increase in Put (18.40 μg g−1 FW) and Cad (9.08 μg g−1 FW) contents were found for 10−9 M EBL plus Cr (VI) metal treatments when compared to Cr (VI) treatment alone. Spermidine (Spd) contents were found to decline significantly for EBL treatment alone or when supplemented with Cr (VI) treatments over untreated controls and Cr (VI) treatment alone. Antioxidant levels were found to enhance, with glutathione (57.98 mg g−1 FW), proline (4.97 mg g−1 FW), glycinebetaine (39.01 μmol mL−1), ascorbic acid (3.17 mg g−1 FW) and phytochelatins (65.69 μmol g−1 FW) contents noted for EBL supplemented to Cr (VI) metal solution over Cr (VI) treatment alone. Reduced activities of guaiacol peroxidase (0.391 U mg−1 protein) and catalase (0.221 U mg−1 protein) and enhanced activities of glutathione reductase (7.14 U mg−1 protein), superoxide dismutase (15.20 U mg−1 protein) and ascorbate peroxidase (4.31 U mg−1 protein) were observed in seedlings treated with EBL plus Cr (VI) over Cr metal treatment alone. Reduced MDA (2.55 μmol g−1 FW) and H2O2 (33.24 μmol g−1 FW) contents were recorded for 10−9 M EBL supplemented to Cr (VI) stress over Cr (VI) treatment alone. Enhancement in free radical scavenging potential as indicated by higher values of 1,1-diphenylpicrylhydrazyl, deoxyribose and reducing power activity assays, and increased levels of phenols and soluble sugars also showed significant influence of EBL in alleviating Cr (VI) stress in radish seedlings.  相似文献   
9.
Recent regulations have required reductions in emissions of nitrogen oxides (NOx) from electric utility boilers. To comply with these regulatory requirements, it is increasingly important to implement state-of-the-art NOx control technologies on coal-fired utility boilers. This paper reviews NOx control options for these boilers. It discusses the established commercial primary and secondary control technologies and examines what is being done to use them more effectively. Furthermore, the paper discusses recent developments in NOx controls. The popular primary control technologies in use in the United States are low-NOx burners and overfire air. Data reflect that average NOx reductions for specific primary controls have ranged from 35% to 63% from 1995 emissions levels. The secondary NOx control technologies applied on U.S. coal-fired utility boilers include reburning, selective noncatalytic reduction (SNCR), and selective catalytic reduction (SCR). Thirty-six U.S. coal-fired utility boilers have installed SNCR, and reported NOx reductions achieved at these applications ranged from 15% to 66%. Recently, SCR has been installed at >150 U.S. coal-fired utility boilers. Data on the performance of 20 SCR systems operating in the United States with low-NOx emissions reflect that in 2003, these units achieved NOx emission rates between 0.04 and 0.07 lb/10(6) Btu.  相似文献   
1
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号