首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   17篇
  免费   0篇
废物处理   3篇
综合类   1篇
污染及防治   11篇
评价与监测   1篇
社会与环境   1篇
  2014年   1篇
  2011年   1篇
  2009年   2篇
  2008年   1篇
  2007年   3篇
  2004年   1篇
  2001年   3篇
  1996年   1篇
  1989年   1篇
  1985年   1篇
  1984年   2篇
排序方式: 共有17条查询结果,搜索用时 31 毫秒
1.
A larval medaka (Oryzias latipes) assay was proposed to evaluate the fish safety level of river waters and wastewaters. Organic toxicants were 10-100 times concentrated with adsorption cartridges from 4 l of river water or 1-10 times concentrated from 400 ml of wastewater. Toxicity of these concentrated solutions was determined by exposing 48-72 h post-hatch age larvae for 48 h. The method effectively revealed a variation of the median lethal concentration ratio (LCR50) from 13 to >100 in 125 river water samples, and from <1 to >10 in five typical wastewater samples. Ayase River, which takes water mostly from agricultural or household discharge, showed significantly (P<0.001) lower LCR50 than Sagami River that takes natural water as the source. Safety Levels in both Sagami River and Ayase River were influenced by the irrigation activity, LCR50 at some sites showing a seasonal-specific decrease in winter. Pollution from pulp and paper industries contributed to the low LCR50 in several tributaries of Ayase River. Required little manpower in sampling, pretreatment and testing, the proposed larval medaka assay was proved as an efficient tool for screening those high risk sites for priority management.  相似文献   
2.
It is necessary to develop technical systems for controlling and monitoring dioxins in stack gas from waste incineration facilities. However, it required much labor, high technical skill and extreme cost to measure dioxins for obtaining the toxic equivalent quantity (TEQ) values. In this study, the positive correlations of the WHO-TEQ values of PCDDs/PCDFs/Co-PCBs or PCDDs/PCDFs with the conventional I-TEQ values of PCDDs/PCDFs were confirmed beforehand for a large number of incineration facilities in a wide concentration range of a hundred thousand times. The relationships between the TEQ values and the concentrations of total PCDDs/PCDFs, each toxic isomer of PCDDs/PCDFs, total Cl4-6BZs, or each homologue of Cl4-6BZs were investigated for various incineration facilities. And it was found that positive correlations of the TEQ values with the concentrations of total PCDDs/PCDFs, 2,3,4,7,8-P5CDF, or Cl5BZ for a large number of different incineration facilities and in a wide concentration range. Consequently, the concentrations of total PCDDs/PCDFs, 2,3,4,7,8-P5CDF and Cl5BZ, whose measuring methods are much easier than that of obtaining the TEQ values, could be used as convenient substitute indices to the TEQ values for controlling and monitoring dioxins in stack gas from various waste incineration facilities.  相似文献   
3.
Much labor, high technical skill and extreme cost are required to measure dioxins for obtaining the toxic equivalent quantity (TEQ) values. On one side, it was found that there were high amounts of chlorobenzenes (CBZs) in the flue gas from waste incineration facilities, and they are also thought to be one of the principal precursors for dioxins. The concentrations of CBZs could be used as a convenient substitute index to the TEQ values for controlling and monitoring dioxins in stack gas from waste incineration facilities as shown in another report. In this study, collection efficiencies in the sampling performed by a convenient train which was composed of two bottles containing water and diethylene glycol in a cooling box, recoveries in the evaporation of the extract by an evaporator, proper procedure of the concentration by nitrogen purge were investigated for measuring CBZs. It was found that tetra-, penta-, and hexa-chlorobenzenes (Cl4-6BZs) whose boiling points are higher than ca. 240 degrees C could be sufficiently collected and recovered in the sampling and the evaporation. For sufficient recoveries of Cl4-6BZs in the concentration by the nitrogen purge, the final volume should be larger than 200 microliters with a proper receiver of the K-D concentrator at 35 degrees C. However, Cl1-3BZs were lost in each of the procedures.  相似文献   
4.
Physico-chemical characteristics of some river and hand-dug well waters used for drinking and domestic purposes in the oil rich Niger Delta area of Nigeria were assessed using standard methods. The concentrations of the parameters in the river water samples ranged in the following order: pH (5.6–6.9), temperature (26.90–28.60°C), turbidity (23–63 NTU), electrical conductivity (52–184 μs/cm), DO (5.4–7.2 mg/l), BOD (21–57 mg/l), TDS (6.0–217 mg/l), PO4 3− (0.19–1.72 mg/l), SO4 2− (25–36.8 mg/l), NO3 (20.3–28 mg/l), Fe (6.07–15.71 mg/l), Zn (0.04–0.24 mg/l), Pb (0.01–0.17 mg/l), Ni (0.01–0.13 mg/l), Vn (0.01–0.20 mg/l) and Hg (0.001–0.002 mg/l). The concentrations of these parameters in the hand-dug well water ranged in the following order: pH (5.7–6.8) temperature (26–30°C), turbidity (134–171 NTU), electrical conductivity (160–340 μs/cm), DO (5.4–6.4 mg/l), BOD (13–34 mg/l), TDS (110–190 mg/l), PO4 3− (0.84–1.84 mg/l), SO4 2− (10.6–28.1 mg/l), NO3 (11.3–23 mg/l), Fe (13.17–16.31 mg/l), Ni (0.01–0.02 mg/l), Vn (0.01–0.04 mg/l) and Hg (0.001–0.004 mg/l). The concentrations of BOD, turbidity, NO3 and Fe in the water samples were above WHO and FMENV permissible limits for safe drinking water. The results suggest that the use of such waters for drinking and domestic purposes pose a serious threat to the health of the users and calls for the intervention of government agencies.  相似文献   
5.
Polycarbonate (PC) pellets were subjected to dilute aqueous ammonia solution under hydrothermal conditions in a semi-batch reactor at temperatures ranging from 433 to 463 K and at a pressure of 10 MPa. The PC pellets were almost completely converted to bisphenol A (BPA). During an initial certain period, referred to as an induction time, neither BPA nor total organic carbon in solution were detected, and the BPA yield increased with time. The monomer yield was well represented by a surface reaction model, two-thirds-order reaction with respect to the mass of unreacted PC. The overall rate constant of the reaction in 0.6 mol/kg aqueous ammonia solution at 433 K was about 15 times greater than that in 0.6 mol/kg NaOH solution. The rate constant at 433 K was proportional to the ammonia or NaOH concentration. There was a correlation between the induction time and temperature, as well as the ammonia or NaOH concentration. By carrying out the reaction in aqueous mixtures of (NH4)2SO4 and NaOH at various concentrations of NaOH, ammonia was confirmed not to function as an alkaline reagent, but as a nucleophile reagent.  相似文献   
6.
K. Miyamoto  K. Urano 《Chemosphere》1996,32(12):2399-2408
Degradation reactions of thirteen chlorinated organic compounds were investigated in a water system and a water-soil system. Three compounds were degraded following the first order rate equation regardless of pH, and five compounds were degraded following the second order rate equation with a concentration of hydroxide ion in alkaline solution.The reaction rate constants and the activation energies of the reactions were obtained, and the intermediates were determined quantitatively for the eight compounds.From the result of the degradation of 1,1,1-trichloroethane in the water-soil system, it was found that 1,1,1 trichloroethane did not react on the soil surface and only reacted in the water phase.  相似文献   
7.
K. Urano  M. Saito  C. Murata 《Chemosphere》1984,13(2):293-300
Adsorption isotherms of 5 priority surfactants on 7 river sediments were obtained. The surfactants were ready to adsorb in the same order as the adsorption on microbiologies. The adsorbed amounts per gram of the organic carbon in the sediments were nearly equal for most of the sediments.  相似文献   
8.
K. Urano  M. Saito 《Chemosphere》1985,14(9):1333-1342
Changes of BOD/TOD and DOC with time were obtained for solutions of 9 synthetic surfactants and 2 fatty acid salts under various conditions. The cationic surfactants, ABM and ABDM, were not biodegraded at all and inhibited the biodegradation of a synthetic sewage. LAS was not biodegraded at concentration of 30 mg/l and higher and inhibited the biodegradation of the sewage.  相似文献   
9.
Urano K  Kato M  Nagayanagi Y  Saito Y  Aono A  Nagata J  Syudo H 《Chemosphere》2001,43(4-7):425-431
An efficient sampling method for dioxins from flue gas, an efficient automatic purification and fractionation method by a new HPLC system using a sulfuric acid-silica/silica column, a Nitro column and a PGC column, and sensitive determination method by an economical HRGC/LRMS using a programmable temperature vaporization (PTV) injector were developed. It was confirmed that the dioxins could be easily collected by the proposed simple sampling train consisting of only two bottles, and the extracted sample could be purified sufficiently and separated as mono-ortho PCBs, non-ortho PCBs and PCDDs/PCDFs completely with the proposed HPLC system. The peak areas of GC/MS were increased linearly with the injection volume up to 40 microl by the PTV technique, and the sensitivity could be increased to 20 times higher than usual. This convenient measuring method can drastically reduce operation time, consumption of hazardous solvent and cost.  相似文献   
10.
Kim KS  Hirai Y  Kato M  Urano K  Masunaga S 《Chemosphere》2004,55(4):539-553
In this study, we determined the detailed PCB congener patterns in flue gases from eight incinerators and four commercial PCB formulations (Kanechlors). About 160 PCB peaks were identified in samples using a DB-5 column and HRGC/HRMS. The concentration of incinerator stack emission gas ranged from 0.02 to 44 ngWHO-TEQ/Nm3. The ratios of dioxin-like PCBs in the total PCB concentration were from 3.4% to 25.7% and from 0.63% to 9.1% in stack emission gases and Kanechlor samples, respectively. The PCB congener profiles of Kanechlor samples were similar to those of previous studies. To determine characteristic congeners in flue gas and Kanechlor samples, principal component analysis (PCA) of the data was conducted using STATISTICA for Windows 5.0J (StatSoft, Inc.). As a result, we obtained four principal components (PCs) and accounted for 74% of the total variance. PC 1 was interpreted combustion, PC 2 and PC 3 were interpreted the difference in the number of substituted chlorines and, PC 4 could not be determined. Moreover, we obtained three groups according to the PCB congeners pattern among samples by PCA. These specific congeners that represent characteristics of each class were identified. These data will be useful for the source analysis of PCBs in the environment.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号