首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   7篇
  免费   0篇
安全科学   1篇
基础理论   3篇
评价与监测   1篇
社会与环境   2篇
  2021年   1篇
  2019年   1篇
  2018年   2篇
  2014年   1篇
  2012年   1篇
  2005年   1篇
排序方式: 共有7条查询结果,搜索用时 15 毫秒
1
1.
It is highly important to analyze the acoustic properties of workrooms in order to identify best noise control measures from the standpoint of noise exposure limits. Due to the fact that sound pressure is dependent upon environments, it cannot be a suitable parameter for determining the share of workroom acoustic characteristics in producing noise pollution. This paper aims to empirically analyze noise source characteristics and acoustic properties of noisy embroidery workrooms based on special parameters. In this regard, reverberation time as the special room acoustic parameter in 30 workrooms was measured based on ISO 3382-2. Sound power quantity of embroidery machines was also determined based on ISO 9614-3. Multiple linear regression was employed for predicting reverberation time based on acoustic features of the workrooms using MATLAB software. The results showed that the measured reverberation times in most of the workrooms were approximately within the ranges recommended by ISO 11690-1. Similarity between reverberation time values calculated by the Sabine formula and measured values was relatively poor (R 2?=?0.39). This can be due to the inaccurate estimation of the acoustic influence of furniture and formula preconditions. Therefore, this value cannot be considered representative of an actual acoustic room. However, the prediction performance of the regression method with root mean square error (RMSE)?=?0.23 s and R 2?=?0.69 is relatively acceptable. Because the sound power of the embroidery machines was relatively high, these sources get the highest priority when it comes to applying noise controls. Finally, an objective approach for the determination of the share of workroom acoustic characteristics in producing noise could facilitate the identification of cost-effective noise controls.  相似文献   
2.
The Reynolds number for flow in a street canyon, Re?=?UrefH/ν (where Uref is a reference velocity, H the street canyon height, and ν the kinematic viscosity), cannot be matched between reduced-scale experiments and full-scale field measurements. This mismatch is often circumvented by satisfying the Re independence criterion, which states that above a critical Re (Rec), the flow field remains invariant with Re. Rec?=?11,000 is often adopted in reduced-scale experiments. In deep street canyons with height-to-width aspect ratio ≥?1.5, reduced-scale experiments have shown two recirculation vortices induced by the mean flows, but full-scale field measurements have observed only one vortex. We investigated this discrepancy by conducting water channel experiments with Re between 104 and 105 at three aspect ratios. The canyons with aspect ratio 1.0 have Rec?=?11,000, the canyons with aspect ratio 1.5 have Rec between 31,000 and 58,000, while the canyons with aspect ratio 2.0 have Rec between 57,000 and 87,000. Therefore, the widely adopted Rec?=?11,000 is not applicable for canyons with aspect ratio greater than 1.5. Our results also confirm that there is only one vortex in deep canyons at high Re. This single-vortex flow regime could change our fundamental understanding of deep canyons, which are often assumed to exhibit multiple-vortex flow regimes. Applications such as numerical model validation based on the multiple-vortex regime should be revisited. Our experimental data with Re up to 105 could be used to validate numerical models at high Re.  相似文献   
3.
Surface discharges of negatively buoyant jets into moving ambient water create a range of complex flow patterns. These complexities arise through the interplay between the discharge’s initial fluxes and the motion of the ambient current. In this study a series of laboratory experiments were conducted for negatively buoyant surface discharges into crossflow to investigate flow patterns under different discharge and ambient conditions. The results compared with simulations of the CORMIX model, an expert system for ocean outfall design. In CORMIX, the simulation module DHYDRO for dense discharges has been used. Finally the flow different patterns were arranged in a dimensionless diagram to propose a modified flow classification system with new criteria.  相似文献   
4.
The result of a general survey on the concentration of fall-out (239+240)Pu in soil collected from several regions in Iran are presented. The samples represent mixed soil averaged over the depth of 0-50 mm. According to the results obtained by alpha spectrometry on 96 soil samples from 32 locations, the (239+240)Pu concentrations vary in the range 80-360 mBq kg(-1). Under normal operating conditions and present counting setup, the minimum detectable activity (MDA) was approximately 8 mBq kg(-1) for soil samples.  相似文献   
5.
Environmental Fluid Mechanics - Atmospheric flow and temperature dynamics in the urban roughness sublayer exhibit numerous complexities that cannot all be investigated using models or scaled-down...  相似文献   
6.
Environment, Development and Sustainability - Despite widespread economic growth and increasing quality of life in the last century, there are concerns that human activities have had a significant...  相似文献   
7.
This study investigated the combined effect of firefighting operations and exposure to smoke on physiological responses, cognitive functions and physical performance among firefighters. Each firefighter was engaged in two experimental conditions: (a) without artificial smoke, control (NS); (b) with artificial smoke (WS). The results of data analysis revealed that heart rate and body temperature increased significantly after the firefighting activities in the two conditions relative to baseline. In addition, reaction time (RT) and correct response (CR) decreased after the activity relative to baseline and there was a significant difference in RT and CR between the NS and WS conditions. There was also a significant difference in performance time between the NS and WS conditions. These findings demonstrated that a smoke compound has an insignificant effect on physiological responses during firefighting activity. On the contrary, the smoke compound has a detrimental influence on cognitive and physical performance.  相似文献   
1
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号