首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   4篇
  免费   0篇
安全科学   4篇
  2023年   1篇
  2015年   1篇
  2013年   2篇
排序方式: 共有4条查询结果,搜索用时 328 毫秒
1
1.
We have conducted numerical simulations of dust dispersion within the NIOSH Rock Dust Dispersion Chamber. The apparatus consists of a low-speed background ventilation flow down a long box in which is placed a tray containing a rock dust powder. A nozzle upstream of the tray introduces a short pulse of a turbulent horizontal jet flow just above the powder surface. We have utilized an incompressible Reynolds-Averaged Navier-Stokes k-ω model for the turbulent flow; particles are incorporated within a one-way Euler-Lagrangian formalism. The Rock Dust Dispersion Chamber ventilation flow exhibits a recirculation zone just above the powder-containing tray. Aerosolization proceeds via the interplay of the jet pulse flow with the background recirculation flow. The air flow is not well-mixed. The aerosolized dust is convected as a concentration cloud downstream towards the detection zone. For larger particles, gravitational settling depletes the convected cloud, so the instrument behaves as a horizontal elutriator. The instrument is robust with respect to misalignment of the jet nozzle. However, reduced streamwise drift velocity allows mixing to disperse the optically detected dust cloud concentration pulse. Our large particle simulation results compare favorably with published experimental results for large, polydisperse calcium carbonate rock dust.  相似文献   
2.
Behavior of dust/air mixtures is very complex and difficult to predict since it depends on material properties as well as boundary conditions. Without other influences airborne particles deposit due to gravity but the time it takes for total deposition as well as easiness of resurrection depends very much on the specific dust sample and the boundary conditions. It still lacks a complete understanding of all interacting reasons and one approach is using experimentally determined characteristics, one is named dustiness.Dustiness is the tendency of dust to form clouds and to stay airborne. Dustiness is determined with two basic principles, which are light attenuation and ratio of filled-in and measured mass. Assessment of dustiness of industrial powders has been done for a long time regarding work place safety. Dustiness is used there to determine inhalable fraction and to evaluate health risks. Lately it became interesting in dust explosion protection as well. Dustiness could be used to optimize determination of zones, adaption of venting area and/or for positioning of suppression systems.Dustiness can be useful in many ways but is not a physical property of dusts, therefore it depends on material properties such as density, particle size distribution, shape and water content as well as boundary conditions or determination method. This makes it very difficult to compare dustiness for different techniques and apparatuses and determination method as well as results should be considered carefully. This work gives an overview of existing standards, recent research and suggests improvements to the new dustiness as proposed for dust explosion protection.  相似文献   
3.
A new safety characteristic the “dustiness” according to VDI 2263 – part 9 (Verein Deutscher Ingenieure, 2008) is investigated. Dustiness means the tendency of a dust to form clouds. The paper deals with the physical reasons for the different behavior of dusts, even if they have similar properties such as particle size and density and the influence of the dustiness on dust explosions. In order to study the effects of the dustiness on dust cloud formation for different dispersion methods experiments in a vertical dust dispersion glass tube apparatus were carried out. Furthermore vented dust explosion experiments were done for two different dispersion methods and two static activation pressures.Experiments show that particle size and density are not the only factors which influence dispersibility. Particle shape, specific surface area, flow and dispersion method have an influence which can outweigh size and density. Preliminary explosion experiments showed that the dustiness has an influence on the reduced explosion pressure and flame speed in a vented 75 L test apparatus. In order to verify the results for applications in the process industries further tests with industrial scale experiments are planned.  相似文献   
4.
A new safety characteristic the “dustiness” according to VDI 2263 – part 9 (Verein Deutscher Ingenieure, 2008) is investigated. Dustiness means the tendency of a dust to form clouds. The paper deals with the influence of the dustiness on vented dust explosions. In order to look into the effects of the dustiness on dust cloud formation and explosion properties experiments and simulations in a vertical dust dispersion glass tube apparatus were carried out.Preliminary explosion experiments showed that the dustiness has an influence on the reduced explosion pressure in a vented 75 L test apparatus. Dusts with comparable pmax and KSt values and different dustiness were tested. Dusts with higher dustiness produced higher overpressures, despite comparable safety characteristics. In order to verify the results for applications in the process industries further tests with different settings are planned as well as industrial scale experiments. Characteristics of the dust such as particle size, density, specific surface area and particle shape, which influence the dispersibility, have been determined experimentally.The Euler/Lagrange and the Euler/Euler approaches are compared for simulating an exemplary dust/air mixture. Especially sedimentation and the ability of the approaches to simulate the tendency of dust to stay airborne were investigated. The Euler/Lagrange approach is better suited for simulating local dust concentrations, particle size distributions and particle forces. It could be used to point out regions of high dust concentrations in a vessel. With the Euler/Euler method it is possible to achieve fast solutions for one specified diameter, but the simulated dust/air mixtures are always more homogenous than in reality. ANSYS CFX version 13 was used in all simulations.  相似文献   
1
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号