排序方式: 共有33条查询结果,搜索用时 31 毫秒
1.
The aim of the study was to compare the performances of the Brungraber Mark II (BM II) and Mark III (BM III) slipmeters. Friction measurements with the two slipmeters were conducted in a laboratory using four footwear materials, four floor types, and three surface conditions. Both the coefficient of friction (COF) values obtained with the slipmeters and the force platform-based COF values were measured. The COF measured with the BM II was slightly higher than that measured with the BM III with a R2 of 0.83. A comparison of the averaged normal force between the two slipmeters showed that the BM II generated a significantly higher normal force than the BM III at a low COF and the difference of the normal force between the two slipmeters decreased when the COF value was increased. The regression analysis results in this study showed that the force platform-based COF values were closer to the COF values obtained with the BM III than with the BM II. The R2 values for the regression model between the COF values obtained from the slipmeter and the force platform were 0.90 and 0.79 for the BM II and BM III, respectively. 相似文献
2.
锚索拉断火花引爆瓦斯的实验研究 总被引:3,自引:0,他引:3
设计了锚索拉断火花引爆瓦斯实验装置 ,在瓦斯浓度为爆炸范围的环境中 ,对锚索拉断时产生火花规律及引起瓦斯爆炸的可能性进行了一系列实验研究。结果表明 :锚索拉断产生火花的概率为 5 0 % ,锚索钢绞线破断产生的火花不能引起瓦斯爆炸。采用红外热成象仪对锚索拉断火花温度的测试表明 ,锚索拉断产生的火花最高温度远小于瓦斯爆炸所需的最低点燃温度 6 5 0℃。 相似文献
3.
The required coefficient of friction (RCOF) is one of the critical elements in determining whether a slip incident might occur. Most researchers, when measuring RCOF, do not differentiate between the two feet of the same participant under the same walking condition. Results from a recent study (Chang et al., 2010) indicated that the stochastic distributions of the RCOF of both feet were different in 76% of the cases. Using the previous data (Chang et al., 2010), this paper presents a comparison of the RCOF for both feet of 50 participants under four level walking conditions resulting from two footwear types and two walking speeds using a t-test, commonly used by safety professionals to compare two pools of data. The current results indicated that 78% of the RCOF data showed a statistically significant difference between the RCOF from two feet for the same participant under each walking condition. The results of the logistic regression analysis used to identify factors that contributed to the outcome of the t-test indicated that the walking speed was the only factor with a statistical significance (p = 0.044). 相似文献
4.
5.
Nearly 130 years ago Holtzwart and von Meyer (1891) demonstrated by experiments that explosible dust clouds could be ignited by inductive electric sparks. Then more than half a century passed before the publication of the important quantitative research of Boyle and Llewellyn (1950) and Line et al. (1959). They worked with capacitive electric sparks and found that the minimum capacitor energies ½CU2 required for ignition of various dust clouds in air decreased substantially when a large series resistance, in the range 104–107 Ω, was introduced in the discharge circuit. When considering that the net energies of the sparks themselves were only of the order of 10% of the ½CU2 discharged, the minimum net spark energies required for ignition with a large series resistance were only a few per cent of the net energies required without such a resistance.Line et al. observed that the essential effect of increasing the series resistance, and hence increasing the discharge time of the sparks, was to reduce the disturbance of the dust cloud by the blast wave from the spark. This phenomenon was explored further by Eckhoff (1970, 2017), and subsequently by some simple experiments by Eckhoff and Enstad (1976). Franke (1974, 1977) and Laar (1980) confirmed the additional finding of Line et al. (1959) that the minimum ½CU2 for ignition is also substantially reduced by including a series inductance in the discharge circuit, rather than a series resistance. The basic reason is the same as with a large series resistance, viz. increased spark discharge time and hence decreased disturbance of the dust cloud by blast wave from the spark. For this reason inclusion of an appreciable series inductance in the spark discharge circuit is an essential element in current standard MIE test methods.In experiments with spark ignition of transient dust clouds produced by a blast of air in a closed vessel, it is necessary to synchronize the occurrence of the spark with the formation of the dust cloud. The precision required from this type of synchronization is typically of the order of 10 ms, which can be obtained even by mechanical arrangements, such as rapid change of spark gap length, or of the distance between two capacitor plates. The present paper reviews some methods that have been/are being used for achieving adequate synchronization of dust cloud appearance and spark discharge. Some current standard experimental methods for determining MIEs of dust clouds experimentally have also been reviewed. The same applies to some theories of electric-spark ignition of dust clouds.At the end of paper some suggestions for possible future modifications of current standard methods for measuring MIEs of explosible dust clouds are presented. With regard to justifying significant modifications of existing standard methods, the “bottom line” is, as quite often in many connections, that any modifications should be based on realistic cost/benefit evaluations. 相似文献
6.
7.
《Journal of Manufacturing Processes》2014,16(2):276-283
The automotive industry is developing designs and manufacturing processes for new generations of electric motors intended for use in hybrid and electric vehicles. There is interest in replacing the aluminum traditionally used in induction motor rotors with copper to improve motor capability. This paper focuses on solid-state welding to join copper end rings to copper spokes in the fabrication of copper rotors. Inertia friction welding was explored to examine weldability of these copper components. A better understanding of inertia welding characteristics will help the advancements in its application for induction rotors. The limitations of this application are discussed. 相似文献
8.
9.
在本研究中,对碳钢、铍青铜和铜镍锰合金等三种金属与砂轮和45号钢轮摩擦时产生火花的能力和引燃能力作了对比实验。用于实验的可燃混合气为液化石油气/空气和氢/空气。实验表明,碳钢和砂轮摩擦产生的火花最强烈,但仍很难引燃液化石油气/空气混合气;铍青铜与砂轮摩擦时几乎看不到火花,铜镍锰合金在同样条件下产生火花的几率销大。在摩擦时间较长的条件下,两者均能引燃极易爆炸的氢/空气混合气,但爆炸却并不是在火花出现时立即发生的。可以推断:在上述条件下,摩擦造成的炽热表面是引燃的主要原因,而材料的引燃能力的强弱,不能只以是否产生火花为判断基准。 相似文献
10.
Current standard test methods for electric-spark minimum ignition energies (MIEs) of dust clouds in air require that a series inductance of at least 1–2 mH be included in the electric-spark discharge circuit. The reason is to prolong the spark discharge duration and thus minimize the spark energy required for ignition. However, when assessing the minimum electrostatic energy ½CU2 for dust cloud ignition by accidental electrostatic-spark discharges, current testing standards require that the series inductance of at least 1–2 mH be removed from the spark discharge circuit. No other changes of apparatus and test procedure are required. The present paper questions whether this simple approach is always adequate. The reason is that in practice in industry accidental electrostatic-spark discharge circuits may contain large ohmic resistances due to corrosion, poor electrical grounding connections, poorly electrically conducting construction materials etc. The result is increased spark discharge durations and reduced mechanical disturbance of the dust cloud by the blast wave emitted by the spark. Therefore, testing for minimum ½CU2 for ignition by accidental electrostatic spark discharges may not only require removal of the series inductance of 1–2 mH from the standard MIE spark discharge circuit. Additional tests may be needed with one or more quite large series resistances Rs inserted into the spark discharge circuit. The present paper proposes a modified standard test procedure for measurement of the minimum electrostatic-spark ignition energy of dust clouds that accounts for these effects. 相似文献