Performance evaluation of Health, Safety and Environment (HSE) is the measurement of a company's achievement in HSE management. In order to receive a comprehensive and objective evaluation result, it is necessary to consider all evaluation factors and experts at different levels when HSE performance assessment is conducted. To improve conventional HSE performance evaluation, where weighted average method was used, a Fuzzy Comprehensive Evaluation (FCE) method is used in this study by taking experts' weights into account. Further, an HSE operating performance assessment system is designed to simplify manual and complex assessment process and generate charts and analysis reports automatically. Finally, a case of petrochemical enterprise is used to illustrate the effectiveness of the method and system. 相似文献
Objectives: The accuracy of self-reported driving exposure has questioned the validity of using self-reported mileage to inform research questions. Studies examining the accuracy of self-reported driving exposure compared to objective measures find low validity, with drivers overestimating and underestimating driving distance. The aims of the current study were to (1) examine the discrepancy between self-reported annual mileage and driving exposure the following year and (2) investigate whether these differences depended on age and annual mileage.
Methods: Two estimates of drivers’ self-reported annual mileage collected during vehicle installation (obtained via prestudy questionnaires) and approximated annual mileage driven (based upon Global Positioning System data) were acquired from 3,323 participants who participated in the Strategic Highway Research Program 2 (SHRP2) Naturalistic Driving Study.
Results: A Wilcoxon signed rank test showed that there was a significant difference between self-reported and annual driving exposure during participation in SHRP 2, with the majority of self-reported responses overestimating annual mileage the following year, irrespective of whether an ordinal or ratio variable was examined. Over 15% of participants provided self-reported responses with over 100% deviation, which were exclusive to participants underestimating annual mileage. Further, deviations in reporting differed between participants who had low, medium, and high exposure, as well as between participants in different age groups.
Conclusions: These findings indicate that although self-reported annual mileage is heavily relied on for research, such estimates of driving distance may be an overestimate of current or future mileage and can influence the validity of prior research that has utilized estimates of driving exposure. 相似文献
PM_(2.5) separator directly affects the accuracy of PM_(2.5) sampling.The specification testing and evaluation for PM_(2.5) separator is particularly important,especially under China's wide variation of terrain and climate.In this study,first a static test apparatus based on polydisperse aerosol was established and calibrated to evaluate the performance of the PM_(2.5) separators.A uniform mixing chamber was developed to make particles mix completely.The aerosol concentration relative standard deviations of three test points at the same horizontal chamber position were less than 0.57%,and the particle size distribution obeyed logarithmic normal distribution with an R~2 of 0.996.The flow rate deviation between the measurement and the set point flow rate agreed to within ± 1.0% in the range of -40 to 50℃.Secondly,the separation,flow and loading characteristics of three cyclone separators(VSCC-A,SCC-A and SCC112) were evaluated using this system.The results showed that the 50% cutoff sizes(D_(50)) of the three cyclones were 2.48,2.47 and 2.44 μm when worked at the manufacturer's recommended flow rates,respectively.The geometric standard deviation(GSD) of the capture efficiency of VSCCA was 1.23,showed a slightly sharper than SCC-A(GSD = 1.27),while the SCC112 did not meet the relevant indicator(GSD = 1.2 ± 0.1) with a GSD = 1.44.The flow rate and loading test had a great effect on D_(50),while the GSD remained almost the same as before.In addition,the maintenance frequency under different air pollution conditions of the cyclones was summarized according to the loading test. 相似文献
Particulate matter suspended in the air has adverse effects onhuman health. Its level of concentration is an important parameter in evaluating the degree of hazard it poses to the atmosphere. Conventional methods used in measuring particulatematter are often filter-based, which indicates some disadvantagesbecause such a base requires labor and time. In this study, to achieve real-time measurements, a new electrical method was developed for measuring PM10 and PM2.5 concentrations. The basicprinciple is to electrically charge particles passing through thePM inlet using a corona charger and measure the currents createdby charged particles to obtain the number concentration of particulate matter. A new type inlet based on the particle cupimpactor configuration was designed and its performance was evaluated. A unipolar diffusion charger was developed and thecharger's efficiency was determined experimentally in terms ofPn, which represents the penetration through the charger,P, times the average charge number acquired by a particle,n, for different particle sizes. The correlation was constructed between the PM10 (or the PM2.5) mass concentrationsand the electrical currents due to particles, which were chargedby the diffusion charger. 相似文献
Kimpo metropolitan landfill has received various kinds of wastessince January 1992. The leachate level was measured to be 10.3 m in May 1995 and the level increased to 12.2 m in August 1996. Therefore, to prove the reason for the increasing leachate level, we calibrated hydraulic conductivity of each waste andintermediate layer using the HELP (Hydrologic Evaluation ofLandfill Performance) model. The leachate generation data measured from February 1993 to October 1995 was used in the model calibration. As a result of a model calibration, we obtained anaverage infiltration ratio and used this in analysis of the total water balance to predict elevation of leachate level. Main causes of the elevation of the leachate level were the high water content of the waste and the degradation of the leachate-drainage system caused by the subsidence of a naturalbarrier layer. 相似文献
We evaluate a field method for determining species richness andcanopy cover of vascular plants for the Forest Health MonitoringProgram (FHM), an ecological survey of U.S. forests. Measurementsare taken within 12 1-m2 quadrats on 1/15 ha plots in FHM.Species richness and cover are determined for four height classes(strata) within each quadrat and aggregated by stratum over the entireplot. We estimated (1) the agreement between experienced trainers andinexperienced technicians who collected the data on this survey(accuracy) and (2) the agreement among the technicians (precision) forresults on species richness and cover from 3 test plots at 3 timeintervals. The methods appear to be highly precise, although somediscrepancies with the values obtained by the trainers were found.Trainers found significantly more species in the ground stratum (0–0.6 m) and measured significantly more cover in the uppermost stratum(>4.9 m). The proportion of variation due to measurement error andtemporal variability was less than 13% for species richness (all strata)and cover (all but one stratum). This indicates that the method issuitable for monitoring changes in species richness and canopy coverfor a large-scale synoptic monitoring project such as FHM. 相似文献