首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   10篇
  免费   0篇
  国内免费   5篇
废物处理   2篇
综合类   5篇
基础理论   4篇
污染及防治   4篇
  2021年   4篇
  2018年   3篇
  2015年   1篇
  2014年   2篇
  2012年   2篇
  2011年   1篇
  2008年   1篇
  2006年   1篇
排序方式: 共有15条查询结果,搜索用时 15 毫秒
1.
Bioaerosols from wastewater treatment processes are a significant subgroup of atmospheric aerosols. In the present study,airborne microorganisms generated from a wastewater treatment station(WWTS) that uses an oxidation ditch process were diminished by ventilation.Conventional sampling and detection methods combined with cloning/sequencing techniques were applied to determine the groups,concentrations,size distributions,and species diversity of airborne microorganisms before and after ventilation. There were 3021 ± 537 CFU/m3 of airborne bacteria and 926 ± 132 CFU/m3 of airborne fungi present in the WWTS bioaerosol.Results showed that the ventilation reduced airborne microorganisms significantly compared to the air in the WWTS. Over 60% of airborne bacteria and airborne fungi could be reduced after4 hr of air exchange. The highest removal(92.1% for airborne bacteria and 89.1% for fungi) was achieved for 0.65–1.1 μm sized particles. The bioaerosol particles over 4.7 μm were also reduced effectively. Large particles tended to be lost by gravitational settling and small particles were generally carried away,which led to the relatively easy reduction of bioaerosol particles0.65–1.1 μm and over 4.7 μm in size. An obvious variation occurred in the structure of the bacterial communities when ventilation was applied to control the airborne microorganisms in enclosed spaces.  相似文献   
2.
3.
•ZnO/Perlite inactivated 72% of bioaerosols in continuous gas phase. •TiO2 triggered the highest level of cytotoxicity with 95% dead cells onto Poraver. •Inactivation mechanism occurred by membrane damage, morphological changes and lysis. •ZnO/Poraver showed null inactivation of bioaerosols. •Catalysts losses at the outlet of the photoreactor for all systems were negligible. Bioaerosols are airborne microorganisms that cause infectious sickness, respiratory and chronic health issues. They have become a latent threat, particularly in indoor environment. Photocatalysis is a promising process to inactivate completely bioaerosols from air. However, in systems treating a continuous air flow, catalysts can be partially lost in the gaseous effluent. To avoid such phenomenon, supporting materials can be used to fix catalysts. In the present work, four photocatalytic systems using Perlite or Poraver glass beads impregnated with ZnO or TiO2 were tested. The inactivation mechanism of bioaerosols and the cytotoxic effect of the catalysts to bioaerosols were studied. The plug flow photocatalytic reactor treated a bioaerosol flow of 460×1 06 cells/m3air with a residence time of 5.7 s. Flow Cytometry (FC) was used to quantify and characterize bioaerosols in terms of dead, injured and live cells. The most efficient system was ZnO/Perlite with 72% inactivation of bioaerosols, maintaining such inactivation during 7.5 h due to the higher water retention capacity of Perlite (2.8 mL/gPerlite) in comparison with Poraver (1.5 mL/gPerlite). However, a global balance showed that TiO2/Poraver system triggered the highest level of cytotoxicity to bioaerosols retained on the support after 96 h with 95% of dead cells. SEM and FC analyses showed that the mechanism of inactivation with ZnO was based on membrane damage, morphological cell changes and cell lysis; whereas only membrane damage and cell lysis were involved with TiO2. Overall, results highlighted that photocatalytic technologies can completely inactivate bioaerosols in indoor environments.  相似文献   
4.
Aeolian dust particles arising from arid and semiarid zones are known to carry microbes by air currents. The effect of wind-borne bacteria on atmospheric bacterial population at various downwind distances from the dust source regions must be clarified, but has not yet been reported. This study monitored the bacterial abundance and community composition in outdoor aerosol samples in Beijing, China, which is close to the Asian dust source regions, and compared them with the results obtained in a distant region(Osaka, Japan).The Asian dust collected in Beijing contained(4 ± 3) × 10~4 bacterial cells/m~3, approximately~4 times higher than in Osaka. On 15 April 2015, Beijing experienced severe Asian dust events with a 1000-fold increase in bacterial abundance, relative to non-Asian dust days. Dominant bacterial phyla and classes in Asian dust collected in Beijing were Actinobacteria, Bacilli and Acidobacteria, and the bacterial community composition varied more widely than in Osaka.The bacterial community compositions differed between the Beijing and Osaka dusts, even for the same Asian dust events. These results indicated that aerosol bacterial communities nearer the dust source are more affected by eolian dust than their distant counterparts.  相似文献   
5.
Microbial diversity and abundance in bioaerosols of a coal mine were analyzed based on 454 pyrosequencing and real-time polymerase chain reaction(PCR). A total of 37,191 high quality sequences were obtained and could be classified into 531, 1730 and 448 operational taxonomic units respectively for archaea, bacteria and fungi at 97% sequence similarity. The Shannon diversity index for archaea, bacteria and fungi was respectively 4.71, 6.29 and 3.86, indicating a high diversity in coal mine bioaerosols. Crenarchaeota, Proteobacteria and Ascomycota were the dominant phyla for archaea, bacteria and fungi, respectively. The concentrations of total archaea, bacteria and fungi were 1.44 × 108, 1.02 × 108 and 9.60 × 104cells/m3, respectively.Methanotrophs observed in bioaerosols suggested possible methane oxidation in the coal mine. The identified potential pathogens to coal miners, such as Acinetobacter schindleri,Aeromonas cavernicola, Alternaria alternata, Aspergillus penicillioides, Cladosporium cladosporioides,and Penicillium brevicompactum were also observed. This was the first investigation of microbial diversity and abundance in coal mine bioaerosols. The investigation of microbial communities would be favorable in promoting the progress of methane control based on microbial technique and concern on coal miners’ health.  相似文献   
6.
In 2007, a program was initiated to monitor air levels of volatile organic compounds (VOCs) and bioaerosols in the vicinity of a municipal solid waste incinerator (MSWI) (Tarragona, Catalonia, Spain). To investigate the temporal trends of chemical and microbiological pollutants, four 6-monthly campaigns were performed. Air samples were collected at different distances and directions from the facility, as well as in reference sites. In general terms, the concentrations of microbiological agents were very similar to those found in urban zones worldwide. The seasonal evaluation of the results showed higher levels of gram-negative bacteria in winter, contrasting with the increase of the airborne amount of total bacteria in summer. On the other hand, the concentrations of VOCs (mean range: 7.6-18.2 μgm−3) were typical of suburban zones. The current exposure to those compounds should not mean additional health risks for the population living nearby.  相似文献   
7.
In the developing world, the vast majority of people rely on solid biomass fuels for cooking and heating which results in poor indoor air quality. The present study determined indoor air quality in some rural and urban areas of Pakistan. Measurements were made of particulate mass (PM10, PM2.5 and PM1), number concentration and bioaerosols in different micro environments. PM10 concentrations of up to 8,555 μg/m3 were observed inside the kitchens where biofuels were used as energy source. Cleaning and smoking was identified as a major source of indoor particulate pollution and concentrations of more than more than 2,000 μg/m3 were recorded in the living room during these activities. Indoor number concentrations in Lahore were typically greater than those observed outdoors in European cites. At a rural site the highest Colony Forming Units (CFUs) were in the 0.5 μm–2 μm size fraction, while at the urban location CFUs were dominant for 2 μm–16 μm. It was observed that CFUs(Colony Forming Units) counts were higher inside living rooms than kitchens. It is important to note that women and children were exposed to extremely high levels of particulates during cooking. Overall, indoor air quality in Pakistan was poor and there is a dire need to take a serious step to combat with it.  相似文献   
8.
Bioaerosols are produced in the process of wastewater biological treatment. • The concentration of bioaerosol indoor is higher than outdoor. Bioaerosols contain large amounts of potentially pathogenic biomass and chemicals. • Inhalation is the main route of exposure of bioaerosol. • Both the workers and the surrounding residents will be affected by the bioaerosol. Bioaerosols are defined as airborne particles (0.05–100 mm in size) of biological origin. They are considered potentially harmful to human health as they can contain pathogens such as bacteria, fungi, and viruses. This review summarizes the most recent research on the health risks of bioaerosols emitted from wastewater treatment plants (WWTPs) in order to improve the control of such bioaerosols. The concentration and size distribution of WWTP bioaerosols; their major emission sources, composition, and health risks; and considerations for future research are discussed. The major themes and findings in the literature are as follows: the major emission sources of WWTP bioaerosols include screen rooms, sludge-dewatering rooms, and aeration tanks; the bioaerosol concentrations in screen and sludge-dewatering rooms are higher than those outdoors. WWTP bioaerosols contain a variety of potentially pathogenic bacteria, fungi, antibiotic resistance genes, viruses, endotoxins, and toxic metal(loid)s. These potentially pathogenic substances spread with the bioaerosols, thereby posing health risks to workers and residents in and around the WWTP. Inhalation has been identified as the main exposure route, and children are at a higher risk of this than adults. Future studies should identify emerging contaminants, establish health risk assessments, and develop prevention and control systems.  相似文献   
9.
Sulfur dioxide(SO_2) and benzene homologs are frequently present in the off-gas during the process of sewage sludge drying. A laboratory scale biofilter was set up to co-treat SO_2 and o-xylene in the present study. SO_2 and o-xylene could be removed simultaneously in a single biofilter. Their concentration ratio in the inlet stream influenced the removal efficiencies. It is worth noting that the removal of SO_2 could be enhanced when low concentrations of o-xylene were introduced into the biofilter. Pseudomonas sp., Paenibacillus sp., and Bacillus sp. were the main functional bacteria groups in the biofilter. Sulfur-oxidizing bacteria(SOB) and o-xylene-degrading bacteria(XB) thrived in the biofilter and their counts as well as their growth rate increased with the increase in amount of SO_2 and o-xylene supplied. The microbial populations differed in counts and species due to the properties and components of the compounds being treated in the biofilter. The presence of mixed substrates enhanced the diversity of the microbial population. During the treatment process, bioaerosols including potentially pathogenic bacteria, e.g., Acinetobacter lwoffii and Aeromonas sp., were emitted from the biofilter. Further investigation is needed to focus on the potential hazards caused by the bioaerosols emitted from waste gas treatment bioreactors.  相似文献   
10.
This article reviews interactions and health impacts of physical, chemical, and biological weather. Interactions and synergistic effects between the three types of weather call for integrated assessment, forecasting, and communication of air quality. Today’s air quality legislation falls short of addressing air quality degradation by biological weather, despite increasing evidence for the feasibility of both mitigation and adaptation policy options. In comparison with the existing capabilities for physical and chemical weather, the monitoring of biological weather is lacking stable operational agreements and resources. Furthermore, integrated effects of physical, chemical, and biological weather suggest a critical review of air quality management practices. Additional research is required to improve the coupled modeling of physical, chemical, and biological weather as well as the assessment and communication of integrated air quality. Findings from several recent COST Actions underline the importance of an increased dialog between scientists from the fields of meteorology, air quality, aerobiology, health, and policy makers.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号