排序方式: 共有16条查询结果,搜索用时 46 毫秒
1.
Lasse Wallquist Vivianne H.M. Visschers Michael Siegrist 《International Journal of Greenhouse Gas Control》2009,3(5):652-657
Laypeople's acceptance and perception of Carbon Dioxide Capture and Storage (CCS) can have an influence on its political feasibility. It is important, therefore, to study how laypeople perceive CCS and which cognitions they hold with respect to this technique. We conducted in-depth interviews with laypeople (N = 16) to explore their mental concepts of CCS. Little knowledge about CCS was detected among laypeople. We also found that laypeople fear that a deployment of CCS could create incentives that would hinder a sustainable development of the energy economy. A misunderstanding of the concepts of hydro- and geostatic pressure, as well as a lack of knowledge about the physical–chemical properties of carbon dioxide seemed to trigger fundamental rejection of CCS among some laypeople. This qualitative study identifies concepts that underlie CCS perception, and these should be objects of future studies. We provide some suggestions for risk management and communication about CCS. 相似文献
2.
火电厂CO2减排技术主要包括燃烧前处理、燃烧中减排及燃烧后捕集三类。介绍了IGCC、富氧燃烧、胺吸收法、生物法等CO2捕集与封存技术,分析其存在问题及应用前景。 相似文献
3.
4.
Carlos A. Grande Alírio E. Rodrigues 《International Journal of Greenhouse Gas Control》2008,2(2):194-202
One of the most important sources of CO2 emissions are the fossil-fuel fired plants for production of electricity. Removal of CO2 from flue gas streams for further sequestration has been proposed by the International Panel on Climate Change experts as one of the most reliable solutions to mitigate anthropogenic greenhouse emissions. When natural gas is employed as fuel, the molar fraction of CO2 in the flue gas is lower than 5% causing serious problems for capture. The purpose of this work is to present experimental validation of an Electric Swing Adsorption (ESA) technology that may be employed for carbon capture for low molar fractions of CO2 in the flue gas streams. To improve energy utilization, an activated carbon honeycomb monolith with low electrical resistivity was employed as selective adsorbent. A mathematical model for this honeycomb is proposed as well as different ESA cycles for CO2 capture. 相似文献
5.
Carbon Capture and Storage (CCS) is a promising technology for reducing carbon emissions, but the public is often reluctant to support it. To understand why public support is lacking, it is crucial to establish what citizens think about the arguments that are used by proponents and opponents of CCS. We determined the persuasiveness, importance and novelty of 32 arguments for and against CCS using a discrete choice experiment in which respondents made consecutive choices between pairs of pro or con arguments. We used latent class models to identify population segments with different preferences. The results show that citizens find arguments about climate protection, which is the primary goal of CCS, less persuasive than other arguments, such as normative arguments (for example ‘a waste product such as CO2 should be disposed of properly’) or arguments about benefits of CCS for energy production and economic growth. This discrepancy complicates communication that aims to convince citizens of the benefits of CCS for climate protection. 相似文献
6.
7.
二氧化碳捕获和存储作为清洁发展机制项目的潜力与障碍分析 总被引:1,自引:0,他引:1
本文目的在于讨论和分析二氧化碳捕获和储存技术项目(CCS)作为清洁发展机制(CDM)项目的障碍和机遇。CCS被视为减少CO2人为排放量的选择方案之一,但在发展中国家,该技术面临着政策、成本和技术上的挑战。对这些国家而言,CDM几乎是发展CCS的唯一动机。本文分析了CCS作为CDM项目面临的项目边界、持久性、渗漏和可持续发展性的问题,并展望了未来的发展趋势。 相似文献
8.
在2060年碳中和目标的要求下,碳捕集、利用与封存技术将扮演重要角色。目前碳捕集、利用与封存技术在中国尚处于工业示范阶段,面临技术成熟度不足、经济成本高、融资渠道单一、应用领域有限、盈利能力差等障碍,迫切需要建立合理的商业模式以推进技术部署。本文梳理了国际上现有的碳捕集、利用与封存商业化项目和相关支持政策,基于商业模式画布的研究框架,分析了碳捕集、利用与封存商业化部署的现状、特点与障碍,并在此基础上提出了相应建议,包括加强技术研发、完善政策体系、布局基础设施和促进集群建设。 相似文献
9.
Earlier studies on fault diagnosis of the pipeline and pump unit systems (PPU) relied mainly on independent equipment analyses, which usually lead to false alarms because of the loss of information fusion. The aim of this study is to utilize the status coupling relationship to improve fault detection sensitivity and reduce false alarm rate. A real-time status identification of related equipment step is added between capturing abnormal signals and listing out diagnosis results. For example, when the pipeline pressure fluctuation is found abnormal, a status analysis of pump units is performed immediately, if the pump units are proven to be operational normally, then the pipeline leak alarm is acknowledged valid. The logical reasoning algorithm is used to capture abnormal conditions of pipeline pressures. The pump unit faults are captured by combining information from multiple sources. Field applications show that the proposed method significantly improves the PPU fault detection capability on fault detection sensitive and accuracy. 相似文献
10.
D. O. Akinyele R. K. Rayudu Rodney H. G. Tan 《International Journal of Green Energy》2016,13(13):1352-1368
The module performance is an important consideration for selecting PV technologies for electricity production, as well as the economic aspect. Also, PV energy yield under varying environmental conditions is largely dependent on the type of technology used. Therefore, this article presents a comparative analysis of different PV modules, of the same power, namely, monocrystalline, polycrystalline, amorphous silicon and hybrid, based on performance, cost and space requirement. The performance is evaluated in terms of module power output, yield, capture losses, fill factor and efficiency, according to the IEC 61724 standards, using Gwako, Nigeria as a case study. A novel technique called Fundamental PV Module Performance Analysis is used to analyze and compare the performance of the PV modules. The performance of a single module is then employed to calculate the overall performance of a PV array designed for a small off-grid house, and a suitable module is determined amongst the modules under study. Results provide insights into the behaviors of the different technologies with the environmental factors of the location, which have an impact on their power and kWh/kW outputs and the efficiency. This knowledge, coupled with the understanding of the constraints of cost and the module space requirements would be useful to researchers, engineers, installers etc. in Nigeria, for planning and developing photovoltaic electric systems for off-grid applications. 相似文献