1.
Flammability limits of binary mixtures of dimethyl ether with five kinds of diluent gases were measured by ASHRAE method at room temperature. The five diluent gases are nitrogen, carbon dioxide, chlorodifluoromethane (HCFC-22), 1,1,1,2-tetrafluoroethane (HFC-134a) and 1,1,1,2,3,3,3-heptafluoropropane (HFC-227ea). The experimental results were correlated with the extended Le Chatelier's formula. It was found that the experimental results were well reproduced by the formula. In addition, flammability limits of binary mixtures of dimethyl ether with nitrogen and carbon dioxide were compared with the estimated values based on the adiabatic flame temperature method. The experimental results were found to be in satisfactory agreement with the estimated values.  相似文献   
2.
In the last decade, the use of renewable resources has increased significantly in order to reduce the energetic dependence on fossil fuels, as they have an important contribution to the global warning and greenhouse gasses effect. Because of that, research on biofuels has been increased in the last years as its characteristics of use match those of the conventional fuel's: solid biomass can be used instead of coals, and biodiesel could replace diesel. Research on solid biomass ignition properties has been considerably developed because of the amount of industrial accidents related to the treatment and use of solid biomass (self-ignition, dust explosions, etc.). On the other hand, thermogravimetric analysis (TGA) is becoming and important characterization technique as it can be used to determine a wide spectrum of properties, such as kinetics, composition, proximate analysis, etc. This research aims to combine thermal analysis and ignition properties, by using the TGA to obtain the elemental composition of lignocellulosic biomass and compare those results to Minimum Ignition Energy (MIE) values test output, so a relation between composition and MIE can be found.To achieve this aim, biomass samples from different origins have been used: oil palm wastes (empty fruit bunches, mesocarp fiber and palm kernel shell), agricultural wastes (straw chops) and forestry wastes (wood chips and wood powder). Also, raw materials and torrefied biomass were compared. The hemicellulose/cellulose ratio was calculated and compared to different flammability properties, finding out that the greater the ratio and the lower the onset temperature (temperature at which the pyrolysis reaction accelerates), the lower was the minimum ignition energy. From this basis it was possible to define “tendency areas” that grouped the samples whose MIE values were similar. Three tendency areas were found: high minimum ignition energy, medium minimum ignition energy, and low ignition energy.  相似文献   
3.
Lower flammability limit (LFL), upper flammability limit (UFL), auto-ignition temperature (AIT) and flash point (FP) are crucial hazardous properties for fire and explosion hazards assessment and consequence analysis. In this study, a comprehensive prediction model set was constructed by using expanded chemical mixture databases of chemical mixture hazardous properties. Machine learning based gradient boosting quantitative structure-property relationship (GB-QSPR) method is implemented for the first time to improve the model performance and prediction accuracy. The result shows that all developed models have significantly higher accuracy than other regular QSPR models, with the 5-fold cross-validation RMSE of LFL, UFL, AIT, and FP models being 1.06, 1.14, 1.08, and 1.17, respectively. All developed QSPR models can be used to estimate reliable chemical mixture hazardous properties and provide useful guidance in chemical mixture hazard assessment and consequence analysis.  相似文献   
4.
The flammability of vapors above aqueous solutions of ethanol and acetonitrile was studied experimentally in a 20-L combustion apparatus. No liquid was present in the apparatus, but the vapor concentrations were adjusted to correspond to the vapor in equilibrium with a specified aqueous solution. The experimental results for these two systems show that
• As water is added to the vapor, the lower boundary of the flammability zone decreases. For ethanol, the lower flammability limits (LFL) decreases from 3.7% for pure vapor to 3.2% with saturated water vapor. For acetonitrile, the decrease is from 4.2% to 3.8%. Thus, to a good approximation, the water vapor can be treated as an inert, enabling the data to be displayed on a single flammability triangle diagram. This provides a very simplified method for estimating the flammable behavior for aqueous solutions.

• The upper boundary of the flammability zone is unchanged with the addition of water.

• The limiting oxygen concentration (LOC) is essentially constant for all concentrations of aqueous solutions. The LOC for the pure solvent may be used as a universal LOC for all solvent concentrations.

• The vapor mixture above the aqueous solution is not flammable below a certain liquid mol fraction of flammable. The flammable concentration at which this occurs can be called the maximum safe solvent concentration (MSSC). A method is presented to determine the MSSC from experimental flammability data.

• The oxygen concentration defining the flammable boundary for the vapor decreases rapidly from the MSSC and then increases as the liquid solvent concentration increases.

The calculated adiabatic flame temperature (CAFT) method qualitatively predicts the same behavior as the experimental data.  相似文献   

5.
Rescue operations during mine fires or methane explosions are highly dangerous for rescue workers. The knowledge of the composition of the coal mine atmosphere and the calculations of its explosibility may help to increase the safety of the rescuers. In the Czech Republic, a system called “Mine Gas Laboratory” (DPL) has been used for these purposes. The DPL allows measurement of the composition of the mine atmosphere and transmits the data necessary for evaluation to the surface. Up to now the explosibility evaluation of the coal mine atmosphere has depended either on the rescuers’ experience or on software code calculation. The code called “Vybuchovy trojuhelnik” (explosion triangle) is a graphical computing system intended for fast assessment of explosibility of fuel–air mixture. This article introduces the code and describes two simple methods of explosibility evaluation. The first method is “explosion triangle analysis”—a graphical method based on empirical graphs transformed into equations. The second method uses thermodynamic calculation based on chemical balance dynamics and Gibbs and Helmholtz energy. According to the requirements of the Czech Bureau of Mining (CBU) and Central Mine Rescue Service (HBZS), the code solves the problems of explosion triangle for both standard and non-standard coal mine atmosphere compositions. Unfortunately, the atmosphere composition must be introduced manually due to the unknown format of the data transmitted from the old DPL model. On 1 September 2005, a project started to develop a new system for on-line monitoring and atmosphere explosibility evaluation. The system should be able to measure CO2, O2, CH4, H2 and CO concentrations as well as the wind speed, temperature and humidity. The “Vybuchovy trojuhelnik” code will be used as a basis for explosibility evaluation, and an on-line connection with the new model of DPL will be established.  相似文献   
6.
The aim of this work is to determine the influence of operating parameters such as the dispersion pressure, the ignition delay and height on the dust flammability. A Computational Fluid Dynamics (CFD) simulation, based on an Euler–Lagrange approach, was developed with Ansys Fluent™ and validated experimentally. Such analysis will facilitate the choice of the most conservative conditions for a flammability test. This paper is focused on a case study performed on wheat starch with the modified Hartmann tube. The dispersion process of the powder was studied with granulometric analyses performed in situ and high speed videos. Tests were performed with injections at gas pressure ranging from 3 to 6 bars and the evolution of the particle size distribution (PSD) was recorded at different ignition heights (5, 10 and 15 cm over the dispersion nozzle). The observations highlighted the presence of agglomeration/deagglomeration processes and dust segregation. Besides, a CFD simulation analysis was aimed at evaluating the impact of a set of parameters on the PSD and the local turbulence, which are closely linked to some flammability parameters. For this computational analysis, the CFD simulation was coupled with a collision treatment based on a Discrete Element Method (DEM) in order to consider the cohesive behavior of the combustible dust. Thus the results suggest performing the injection of the gases at approximately 5 bars for the flammability tests of wheat starch in order to obtain the finest PSD at a given ignition height. It is also shown that the finest PSD are obtained at 5 cm over the dispersion nozzle. However, the local instabilities and turbulence levels are so high during the first stages of the dispersion that the flame growth can be disturbed for short ignition delays. Moreover, the stabilization of the bulk of the dust cloud requires longer periods of time when the ignition sources are located at 15 cm. As a result, the recommended height to perform a flammability test is 10 cm in this case. Finally, this study proposes some tools that might improve the procedure of dust flammability testing.  相似文献   
7.
There is a clear difference between exiting data on the measured flammability limits of hydrogen-air mixture. The non-uniformity of concentration distribution of hydrogen in air is a contributor to deviations of the upper flammability limit (UFL) and the lower flammability limit (LFL) measured in different experiments. This paper presents a numerical model to simulate the gas mixing process from start to stability, to predict the concentration distribution, and to research the influence of concentration distribution of hydrogen in air on measured UFLs and LFLs. The commercial software package Fluent was used to carry out the numerical simulation for the concentration distribution of hydrogen in air in the vessels with length-to-diameter ratios (L: D) of 1:1, 3:1, 5:1 and 7:1 respectively. Based on the numerical simulation and analysis, the influence of concentration distribution on measured flammability limits was demonstrated for hydrogen in air in the vessel. It is found that the deviations of measured flammability limits of hydrogen in air are the minimum in the vessel with length-to-diameter ratio of 1:1, and augment with the augmentation of vessel length-to-diameter ratio. Moreover, it is presented that the deviations of measured flammability limits of hydrogen in the center of the vessel are lower than that in the top and the bottom.  相似文献   
8.
Heat transfer fluids tend to form aerosols due to the operating conditions at high pressure when accidental leaking occurs in pipelines or storage vessels, which may cause serious fires and explosions. Due to the physical property complexity of aerosols, it is difficult to define a standard term of “flammability limits” as is possible for gases. The study discussed in this paper primarily focuses on the characterization of ignition conditions and flame development of heat transfer fluid aerosols. The flammable region of a widely-used commercial heat transfer fluid, Paratherm NF (P-NF), was analyzed by electro-spray generation with a laser diffraction particle analysis method. The aerosol ignition behavior depends on the droplet size and concentration of the aerosol. From the adjustment of differently applied electro-spray voltages (7–10 kV) and various liquid feeding rates, a flammable condition distribution was obtained by comparison of droplet size and concentration. An appropriate amount (0.3–1.2 ppm) of smaller droplets (80–110 μm) existing in a given space could result in successful flame formation, while larger droplets (up to 190 μm) have a relatively narrowed range of flammable conditions (0.7–0.9 ppm). It is possible to generate a more useful reference for industry and lab scale consideration when handling liquids. This paper provides initial flammability criteria for analyzing P-NF aerosol fire hazards in terms of droplet size and volumetric concentration, discusses the observation of aerosol combustion processes, and summarizes an ignition delay phenomenon. All of the fundamental study results are to be applied to practical cases with fire hazards analysis, pressurized liquid handling, and mitigation system design once there is a better understanding of aerosols formed by high-flash point materials.  相似文献   
9.
几种地板燃烧性能的实验研究   总被引:4,自引:0,他引:4  
马哲  舒中俊  薛刚  贾源 《火灾科学》2005,14(3):132-136
地板的燃烧性能对室内火灾的发展蔓延及火灾危害都有重要的影响,本文使用锥形量热仪对市场上常见几种地板(实木地板、竹制地板和复合地板)的燃烧性能进行试验研究。实验结果表明,地板的热释放速率具有两个峰,相同辐射功率下,竹地板和实木地板的比消光面积分别比复合地板高29.3%、42.5%,竹制地板点燃时间较小,复合地板火灾危险性要小于竹制地板和实木地板。  相似文献   
10.
Explosion behaviors of typical light metal and carbonaceous dusts induced by different ignition energies were investigated based on systematic experiments in a Siwek 20 L vessel. Comparative analysis reveals that the explosion mechanism of carbonaceous dust is the volatile combustion, whereas the mechanism for light metal dust mainly features the surface heterogeneous oxidation. Influences of ignition energy on severity and flammability limit are much more significant for carbonaceous dust than light metal, especially for the powder with less volatile. An innovative approach was introduced to derive flame thickness from the pressure–time trace. The relation between explosion induction time and combustion duration of ignitor was also analyzed. Results show inappropriate ignition energy will cause under-/over-driving in the thermodynamic/kinetic characteristic measurements. In this way, a dimensionless parameter pressure ratio was introduced to evaluate the under-driving, while two methods by using flame thickness and induction time respectively, were proposed to evaluate over-driving. To improve the accuracy of dust explosion tests, authors advocate that explosion severity determination should be conducted at the critical ignition energy. Moreover, a comparison between the European and Chinese flammability limit determination procedures was also conducted, indicating that EN 14034-3 is suitable for light metal but not for carbonaceous, while GB/T 16425 appears to be slightly conservative for both carbonaceous and light metal dusts.  相似文献   