全文获取类型
收费全文 | 69篇 |
免费 | 2篇 |
国内免费 | 6篇 |
专业分类
安全科学 | 12篇 |
废物处理 | 3篇 |
环保管理 | 5篇 |
综合类 | 21篇 |
基础理论 | 18篇 |
污染及防治 | 8篇 |
评价与监测 | 5篇 |
社会与环境 | 5篇 |
出版年
2024年 | 1篇 |
2023年 | 4篇 |
2022年 | 1篇 |
2021年 | 5篇 |
2020年 | 3篇 |
2019年 | 2篇 |
2018年 | 1篇 |
2017年 | 2篇 |
2016年 | 3篇 |
2015年 | 5篇 |
2014年 | 1篇 |
2013年 | 2篇 |
2012年 | 3篇 |
2011年 | 6篇 |
2010年 | 3篇 |
2009年 | 2篇 |
2008年 | 6篇 |
2007年 | 4篇 |
2006年 | 4篇 |
2005年 | 4篇 |
2004年 | 1篇 |
2003年 | 2篇 |
2002年 | 2篇 |
2001年 | 3篇 |
1996年 | 1篇 |
1995年 | 1篇 |
1993年 | 1篇 |
1992年 | 1篇 |
1991年 | 1篇 |
1990年 | 1篇 |
1982年 | 1篇 |
排序方式: 共有77条查询结果,搜索用时 15 毫秒
1.
Fault detection (FD) and diagnosis in industrial processes is essential to ensure process safety and maintain product quality. Partial least squares (PLS) has been used successfully in process monitoring because it can effectively deal with highly correlated process variables. However, the conventional PLS-based detection metrics, such as the Hotelling's T2 and the Q statistics are ill suited to detect small faults because they only use information from the most recent observations. Other univariate statistical monitoring methods, such as the exponentially weighted moving average (EWMA) control scheme, has shown better abilities to detect small faults. However, EWMA can only be used to monitor single variables. Therefore, the main objective of this paper is to combine the advantages of the univariate EWMA and PLS methods to enhance their performances and widen their applicability in practice. The performance of the proposed PLS-based EWMA FD method was compared with that of the conventional PLS FD method through two simulated examples, one using synthetic data and the other using simulated distillation column data. The simulation results clearly show the effectiveness of the proposed method over the conventional PLS, especially in the presence of faults with small magnitudes. 相似文献
2.
Collections made in the course of long-term field studies on ecology of the northern mole vole Ellobius talpinus Pall. in the Ural Region and neighboring areas (more than 2000 individuals from 24 points of the species range) were used
to analyze geographic variation in its coat color (color morphs). On the basis of long-term observations (1985–1999) on marked
animals from a polymorphic population (Kurtamyshskii raion, Kurgan oblast), the life spans of males and females and the dependence
of life span on population density and structure were estimated in animals of different color morphs. Each color morph of
E. talpinus was shown to have specific features of the seasonal dynamics of age structure and migrations. 相似文献
3.
Long-term stationary studies on the ecology of the northern mole vole (Ellobius talpinus Pall.), performed by the mark–recapture method from 1985 to 1997, have provided original data on population dynamics and structure. The analysis shows that, to reveal cyclic fluctuations of population size in this species, the period of three years should be taken as a unit of time for estimating the duration of one phase. The 12-year population cycle in E. talpinus has four distinct phases: an increase, a peak, a decline, and a minimum. At each phase, the population is characterized by certain features of family structure, age composition, birth and death rates, and the composition of migrants. 相似文献
4.
Da Zhang Jingfeng Gao Lifang Zhang Wenzhi Zhang Jingxin Ji Huihui Dai Zhiqi Wang 《环境科学学报(英文版)》2020,32(6):211-223
Triclosan(TCS) is commonly found in wastewater treatment plants,which often affects biological treatment processes.The responses of nitrification,antibiotic resistome and microbial community under different TCS concentrations in activated sludge system were evaluated in this study.The experiment was conducted in a sequencing batch reactor(SBR)for 240 days.Quantitative PCR results demonstrated that the abundance of ammonium oxidizing bacteria could be temporarily inhibited by 1 mg/L TCS and then gradually recovered.And the abundances of nitrite oxidizing bacteria(NOB) under 2.5 and 4 mg/L TCS were three orders of magnitude lower than that of seed sludge,which accounted for partial nitrification.When the addition of TCS was stopped,the abundance of NOB increased.The mass balance experiments of TCS demonstrated that the primary removal pathway of TCS changed from adsorption to biodegradation as TCS was continuously added into the SBR system.Moreover,TCS increased the abundance of mexB,indicating the efflux pump might be the main TCS-resistance mechanism.As a response to TCS,bacteria could secrete more protein(PN) than polysaccharide.Three-dimensional excitation-emission matrix revealed that tryptophan PN-like substances might be the main component in PN to resist TCS.High-throughput sequencing found that the relative abundances of Paracoccus,Pseudoxanthomonas and Thauera increased,which could secrete extracellular polymeric substances(EPS).And Sphingopyxis might be the main TCS-degrading bacteria.Overall,TCS could cause partial nitrification and increase the relative abundances of EPS-secreting bacteria and TCS-degrading bacteria. 相似文献
5.
The index patient is a female fetus in which prenatal diagnosis of 8p trisomy was established after amniocentesis at 16 weeks of gestation. This fetus was the unbalanced product of a maternal translocation of 5q/8p (karyotype: 46,XX,t(5;8)(q35;pl 1). Internal malformations include an anomalous lobature of the right lung, a little and high atrio-ventricular communication, and an anomaly in the number and shape of the aortic semilunar valves. The possible relationship between the phenotype and the chromosomal abnormality is briefly discussed. 相似文献
6.
Population dynamics and regulation in the cave salamander <Emphasis Type="Italic">Speleomantes strinatii</Emphasis> 总被引:1,自引:0,他引:1
Salvidio S 《Die Naturwissenschaften》2007,94(5):396-400
Time series analysis has been used to evaluate the mechanisms regulating population dynamics of mammals and insects, but has
been rarely applied to amphibian populations. In this study, the influence of endogenous (density-dependent) and exogenous
(density-independent) factors regulating population dynamics of the terrestrial plethodontid salamander Speleomantes strinatii was analysed by means of time series and multiple regression analyses. During the period 1993–2005, S. strinatii population abundance, estimated by a standardised temporary removal method, displayed relatively low fluctuations, and the
autocorrelation function (ACF) analysis showed that the time series had a noncyclic structure. The partial rate correlation
function (PRCF) indicated that a strong first-order negative feedback dominated the endogenous dynamics. Stepwise multiple
regression analysis showed that the only climatic factor influencing population growth rate was the minimum winter temperature.
Thus, at least during the study period, endogenous, density-dependent negative feedback was the main factor affecting the
growth rate of the salamander population, whereas stochastic environmental variables, such as temperature and rainfall, seemed
to play a minor role in regulation. These results stress the importance of considering both exogenous and endogenous factors
when analysing amphibian long-term population dynamics. 相似文献
7.
8.
Binbin Sheng Depeng Wang Xianrong Liu Guangxing Yang Wu Zeng Yiqing Yang Fangang Meng 《Frontiers of Environmental Science & Engineering》2020,14(6):93
9.
Mingxuan Mao Li Zhang Qichang Duan O.J.K Oghorada Pan Duan Bei Hu 《International Journal of Green Energy》2017,14(8):694-702
The power-voltage (P-V) characteristic curves of a PV array are nonlinear and have multiple peaks under partially shaded conditions (PSCs). This paper proposes a novel maximum power point tracking (MPPT) method for a PV system with reduced steady-state oscillation based on a two-stage particle swarm optimization (PSO) algorithm. The grouping method of the shuffled frog leaping algorithm (SFLA) is incorporated in the basic PSO algorithm (PSO-SFLA), ensuring fast and accurate searching of the global extremum. An adaptive speed factor is also introduced into the improved PSO to further enhance its convergence speed. Test results show that the proposed method converges in less than half the time taken by the conventional PSO method, and the power is improved by 33% under the worst PSCs, which confirms the superiority of the proposed method over the standard PSO algorithm in terms of tracking speed and steady-state oscillations under different PSCs. 相似文献
10.
建立了利用组合单标多点校正和英蓝超滤单元的离子色谱法测定地表水中F-、C1-、NO3-、S0424—4-种离子的方法,方法操作简便,灵敏度高,线性范围广,抗干扰能力强,可同时快速测定不同数量级浓度的离子,降低了配置标准品和样品前处理的复杂性,减少了因前处理带来的干扰。 相似文献