Film boiling chemical vapor infiltration (FB-CVI) is considered as one of the fastest process methodologies for manufacturing carbon-carbon (C–C) composite products and possesses various advantages compared to conventional methodologies. However, there are safety concerns associated with this process for large-scale manufacturing, mainly owing to the intrinsic nature of the precursor and the process conditions. Considering the multifunctional interactions of the various systems during the process, a system-theoretic process analysis (STPA)/system theoretic accident model and process (STAMP) model is used to perform a safety analysis of the hazardous states of the FB-CVI process at the system level. As a case study, the FB-CVI process equipment employed for the manufacturing of C–C composites is considered. The safety constraints present in the system are assessed for adequacy through a hazard analysis by STPA/STAMP. The analysis through STPA/STAMP demonstrated the capability to create proactive strategies for the design and realization of process equipment that can be employed to manufacture C–C composite products through the FB-CVI process. 相似文献
在连续流条件下,基于颗粒污泥全程自养脱氮(CANON)工艺的快速启动和混合营养条件下高效脱氮,是CANON工程应用的重要环节.本研究在气提内循环反应器(AIR)中,以老化的CANON颗粒污泥经机械破碎至0.3 mm作为种泥,实现混合营养型单级颗粒污泥同步脱氮除碳.启动26 d,通过控制DO,系统出现稳定的部分硝化,再缩短HRT提升氨氮负荷至5.65 kg ·(m3 ·d)-1,促进颗粒化和厌氧氨氧化;第68 d,总氮去除率达到58%之后,进水加入有机物,C/N从0提升到0.25和0.5,促进AOB、AMX和异养微生物的协同,氨氮去除率达95%,总氮去除率达85%,COD去除率达80%左右.COD浓度增加,能较好地抑制Nitrospira菌属等NOB的活性,q(NH4+-N)和q(TN)稳定在0.4 g ·(g ·h)-1和0.34 g ·(g ·h)-1,q(NO3--N)约为0.02 g ·(g ·h)-1.采用MiSeq高通量测序对微生物多样性分析,表明有机物对污泥中Nitrosomomas和Candidutus_Kuenenia丰度未产生显著影响,增加了Candidutus_Brocadia菌属以及具有反硝化功能Denitratisoma等菌属的丰度.这对于快速启动连续流CANON颗粒污泥工艺处理低C/N比废水提供思路. 相似文献
During the discharge of flashing liquids through leaks due to abrupt depressurization a transient thermodynamic non-equilibrium in the form of a boiling delay in the superheated liquid flow can occur. As a consequence the actual mass flow quality is smaller than calculated under the assumption of an immediate adjustment of the thermodynamic equilibrium between the phases. For the prediction of the leak mass flow for a given pressure difference the magnitude of this self-adjusting mass flow quality is needed.
Most of the models cited in the literature include only the equilibrium mass quality as limiting quantity and ignore further effects as that of the depressurization velocity or the mean nucleus distance. For the assessment of the maximum possible liquid superheat during flashing only the conduction heat transfer from a stagnant liquid to the bubble surface is used to describe the bubble growth.
The sub-model for the bubble growth due to expansion and mass transfer necessary for the global prediction of the transient thermodynamic non-equilibrium in flashing liquids was validated using bubble radii measured by Hooper et al. [Bubble growth and pressure relationship in the flashing of superheated water. Technical publication 6904, Mechanical Engineering Department, University of Toronto, 1969] for the case of a sudden depressurization of initially saturated water. On this basis the calculated time-dependent temperature field, the actual mass quality, the mean liquid temperature and, in comparison to the corresponding values based on the assumption of immediate thermodynamic equilibrium, the maximum possible liquid superheat are predicted. 相似文献