首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   4篇
  免费   0篇
  国内免费   1篇
废物处理   1篇
综合类   2篇
基础理论   2篇
  2013年   1篇
  2008年   1篇
  2006年   1篇
  2004年   1篇
  2000年   1篇
排序方式: 共有5条查询结果,搜索用时 15 毫秒
1
1.
基于在pH为2.7的一氯乙酸缓冲溶液中亚硝酸根对溴酸钾氧化亮绿具有催化作用,建立了测定环境水样中痕量亚硝酸根的流动注射催化光度法。在室温下,当溴酸钾浓度为0.15mol/L、亮绿溶液浓度为1.12×10-3mol/L时,该方法的线性范围为0.04~0.36mg/L,检出限为7.44×10-4mg/L,测定频率为60次/h,相对标准偏差为1.1%(n=11)。  相似文献   
2.
A Ethylene glycol dimethacrylate (EGDMA) methacrylic acid (MAA) resin was used for preconcentration of lead at trace levels in water samples. For this purpose, a flow-injection, solid phase extraction method was developed for the determination of lead by flame atomic absorption spectrometry. Lead ions were sorbed on a EGDMA–MAA column at pH 4, followed by an elution step using 288 µL of 4.0 M nitric acid solution and determination by flame atomic absorption spectrometry. Optimum conditions for quantitative sorption involving the pH, sample volume, loading and elution flow rates, eluent type, and volume were investigated. A 868-fold enrichment factor could be reached. The detection limit for the water samples, estimated from the noise on the signal obtained for 250 mL of 10 µg L?1 loaded at 4.9 mL min?1 was 1.04 µg L?1. The method was applied for lead determination in river water samples collected in Edirne, Turkey. Recoveries of spiked solutions (10 µg L?1) to river water samples were quantitative. Finally, the method was validated by the analysis of certified reference material SRM 2704 (Buffalo River Sediment).  相似文献   
3.
陈树榆  孙梅 《环境化学》2000,19(4):362-368
本文用流动注射在线阳离子交换树脂预富集-火焰原子吸收法测定了标准参考物(头发GBW09 101和桃叶GBW08501)及水样中的微量铜、铅和镉.对铜、铅和镉测定灵敏度分别提高27.0 ,37.5和27.5倍;回收率分别为93.7-109.9%,88.9-101.4%,84.7-103.0% ;分析速度为30次·h-1.对0.05μg·ml-1Cu2+,0.2μg·ml-1 Pb2+,0.02μg·ml-1Cd2+溶液,其测定相对标准偏差(n =11)分别为2.74%,1.05%和2.97%.  相似文献   
4.
A novel chemiluminescence (CL) system for determination of permanganate index (CODMn) combined with flow injection analysis has been proposed in this study. On the basis of the chemiluminescent reaction of luminol-KMnO4 system, light emission caused by luminol-KMnO4 system was detected by the photomultiplier tube, and its intensity caused by the appearance of KMnO4 after sample digestion was inversely proportional to CODMn. Effects for CODMn determining such as pH, concentrations and interference were investigated in detail. A detection limit of 0.3 mg/L CODMn with a linear range of 0.3-200 mg/L for its theoretical CODMn was obtained under the optimized experimental conditions. The relative standard deviation was 4.3% for 5.0 mg/L CODMn (n = 11). This CL flow system for determining CODMn was simple, rapid, and suitable for automatic analysis. The data obtained by the present method were fairly in good agreement with those obtained by the standard titrimetric method. It has been applied to determine real samples with satisfactory results.  相似文献   
5.
悬浮液-流动注射-氢化发生原子荧光法测定沉积物中的Pb   总被引:2,自引:0,他引:2  
研究了一种把悬浮液进样与氢化发生相结合原子荧光光谱法测定沉积物中Pb的方法。控制悬浮液的粒径在0.088mm以下,用磁力搅拌器搅拌以保证悬浮液分散均匀稳定,方法中以盐酸作介质,K3Fe(CN)6为氧化剂,采用水溶液标准作标准曲线测定了沉积物中的Pb,该法的线性范围为0~200μg/L,检出限为0.26μg/L,回收率为92%~107%,精密度小于6.5%。将此法用于标准物质的分析,测定值均在标准值范围之内,结果令人满意,具有实际应用价值。  相似文献   
1
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号