排序方式: 共有45条查询结果,搜索用时 187 毫秒
1.
建立了吹扫捕集-气相色谱法测定水样中乙醛和丙烯醛的方法,并对吹扫捕集测试条件进行优化,考察了吹扫温度和吹扫时间对吹扫捕集效率和方法检出限的影响。在50℃下,吹扫时间为20 min时,该方法乙醛和丙烯醛的检出限分别为0.001 2 mg/L、0.000 6 mg/L,相对标准偏差分别为3.5%~6.9%、2.9%~5.8%,加标回收率分别为91.6%~108%、92.0%~105%。与GB3838-2002推荐使用的分析方法相比较,该方法具有操作简便、灵敏度高、重复性好、基本上不消耗有机溶剂等特点,可满足地表水和废水中乙醛和丙烯醛的测定要求。 相似文献
2.
Aree Choodum Panote Thavarungkul Proespichaya Kanatharana 《Journal of environmental science and health. Part. B》2013,48(5):577-583
A simple sample preparation technique was developed for rapid analysis of acetaldehyde residue in Polyethylene Terephthalate (PET) bottles. A laboratory-built heating system was used and coupled with gas chromatography-flame ionization detector (GC-FID) at optimized conditions. The results were a tremendous reduction of the sample preparation time from 24 hours, for the conventional method, to only one hour. The analysis took only 1.5 min with other good analytical performances i.e. a low detection limit, 0.3 ng mL? 1 and a wide linear dynamic range, 0.3 ng mL? 1 to 6.6 μ g mL? 1 with R2 > 0.99.Acetaldehyde residue in freshly blown bottles were analyzed and found in the range of 0.4 to 1.1 ng mL? 1. The results were good agreement with the conventional 24-hour airspace method (P < 0.01). The PET-bottle sampling technique was also developed to minimize the complication of sample transportation and pre-concentration. A purge and trap technique was found to be the most suitable. Then, it was implemented and compared, the results showed no significant difference (P < 0.01) with and without purge and trap. 相似文献
3.
吹扫捕集与气相色谱-质谱联用测定饮用水和地表水中挥发性有机污染物 总被引:36,自引:1,他引:35
报道了Trap I(VOCARB 4000)柱捕集水中挥发性有机污染物的性能和条件,建立了吹扫捕集和气相色谱-质谱联用测定饮用水和地表水样中25种挥发性有机污染物的分析方法.水样的加标回收率在90%~110%之间,最低检测限在0.04~0.85μg/L之间,20μg/L的挥发性有机物标准溶液经重复6次测定,其相对标准偏差基本小于5.0%.该方法已成功地运用于饮用水和地表水中挥发性有机污染物的测定,结果令人满意. 相似文献
4.
影响吹扫捕集/气相色谱-质谱法测定水中挥发性有机物的因素很多,如空气中的挥发性有机物可能通过采样瓶的扩散,使准确性和可靠性降低。结合环境监测工作实际,按分流比20∶1分流进样,选择11#捕集阱,样品解析时选择解析时间0.5 min,选择吹扫管支座温度为40℃,选择与目标化合物相比相对保留时间在0.8~1.20之间内标物,同时样品采集、保存、运输和器皿清洗等条件严格按照国标方法进行,可以确保吹扫捕集/气相色谱-质谱法测定的精密度和准确度。 相似文献
5.
Aerobic degradation of methyl tert-butyl ether by a Proteobacteria strain in a closed culture system 总被引:4,自引:0,他引:4
The contamination of methyl ten-butyl ether (MTBE) in underground waters has become a widely concerned problem all over the world. In this study, a novel dosed culture system with oxygen supplied by H2O2 was introduced for MTBE aerobic biodegradation. After 7 d, almost all MTBE was degraded by a pure culture, a member of β-Proteobacteria named as PMI, in a closed system with oxygen supply, while only 40% MTBE was degraded in one without oxygen supply. Dissolved oxygen (DO) levels of the broth in closed systems respectively with and without H2O2 were about 5-6 and 4 mg/L. Higher DO may improve the activity of monooxygemase, which is the key enzyme of metabolic pathway from MTBE to tert-butyl alcohol and finally to CO2, and may result in the increase of the degrading activity of PM1 cell. The purge and trap GC-MS result of the broth in closed systems showed that tea-butyl alcohol, isopronol and acetone were the main intermediate products. 相似文献
6.
7.
吹扫—捕集/气相色谱法测定水中挥发性有机物 总被引:3,自引:0,他引:3
为提高样品分析效率,研究并建立了吹扫-捕集/气相色谱/氢火焰检测器联用同时测定水中1,2-二氯乙烷、苯、甲苯、氯苯、乙苯、对-二甲苯、间-二甲苯、苯乙烯、邻-二甲苯、异丙苯、1,4-二氯苯、1,2-二氯苯、硝基苯、1,3,5-三氯苯、1,2,4-三氯苯、1,2,3-三氯苯、六氯丁二烯17种挥发性有机物的分析方法。结果表明,当进样体积为25.0ml时,最低检出限为0.0034-0.1088μg/L,相对标准偏差为1.8%~6.4%,加标平均回收率为97.6%-105.8%。该方法可快速、简便、准确、高灵敏度的测定水中17种挥发性有机物,并适用于饮用水和地表水中挥发性有机物的测定。 相似文献
8.
通过探讨影响四乙基铅富集效率的捕集管类型、吹扫温度和吹扫时间等因素,建立了吹扫捕集-气相色谱法测定水质中四乙基铅的分析方法。实验结果表明,使用Tenax捕集管,在吹扫温度为50℃、吹扫15 min的条件下测定水质中的四乙基铅,捕集效率为97.6%~98.2%,在0~100μg/L范围内线性良好,检出限为0.03μg/L,加标回收率为93.2%~100.5%,相对标准偏差为1.6%~3.2%。方法操作简便快捷、准确、实用且绿色环保不消耗有机溶剂,适于水质中四乙基铅的测定。 相似文献
9.
吹扫捕集气质联用法同时测定水中氯乙烯、乙醛、丙烯醛、丙烯腈、吡啶和松节油 总被引:1,自引:0,他引:1
建立了一种采用吹扫捕集气质联用法同时测定水中氯乙烯、乙醛、丙烯醛、丙烯腈、吡啶和松节油的分析方法,研究并优化了吹扫捕集前处理条件参数。结果表明,吹扫时间、吹扫温度和脱附时间是影响目标物的吹扫捕集效率的关键因素;优化后方法线性良好,相关系数均大于0.999,检出限范围为0.20~1.48μg/L,加标回收率范围为86.9%~105%,相对标准偏差为1.1%~9.8%。建立的吹扫捕集GC-MS联用法简便、快速、灵敏度高、定性定量准确可靠,可同时满足对自来水、地表水、地下水等水样中痕量氯乙烯、乙醛、丙烯醛、丙烯腈、吡啶和松节油监测的要求。 相似文献
10.