排序方式: 共有145条查询结果,搜索用时 15 毫秒
1.
利用Type 0092丝状菌不易引发污泥恶性膨胀的特点,本实验采用实际生活污水,以SBR反应器接种短程硝化污泥,考察了短程硝化状态下启动Type 0092丝状菌污泥微膨胀的特性,研究了系统启动与维持期间的污泥沉降性能、亚硝酸盐积累率(NAR)、污染物去除特性以及污泥菌群结构变化情况.结果表明控制DO为0. 3~0. 8 mg·L~(-1),F/M(以COD/MLSS计)=0. 24 kg·(kg·d)~(-1),按照交替缺氧/好氧模式运行(单周期3次,缺氧∶好氧=20 min∶60 min),能够启动Type 0092丝状菌污泥微膨胀与短程硝化耦合,系统SVI值维持在180 m L·g~(-1)左右,NAR一直维持在99%左右,COD和TN去除率能够分别提高约13%和5%,相较于传统全程硝化非微膨胀状态曝气量能节省约62. 5%.当交替缺氧/好氧模式变为单周期交替6次,缺氧∶好氧=10 min∶30 min,亚硝酸盐氧化菌(NOB)的活性会恢复,使短程硝化被破坏;低溶解氧、交替缺氧/好氧、低负荷是实现Type 0092丝状菌污泥微膨胀的关键因素,当负荷(以COD/MLSS计)大于0. 25 kg·(kg·d)~(-1)时,仅靠低溶解氧和间歇曝气无法维持污泥微膨胀状态. 相似文献
2.
采用连续流ABR-MBR组合工艺处理生活污水,研究不同容积负荷(volume loading rate,VLR)对该工艺反硝化除磷性能的影响,获得最佳工艺参数.试验考察ABR进水容积负荷(以COD计,下同)分别为0.76、1.01、1.51和2.27 kg·(m~3·d)~(-1)时系统去碳脱氮除磷的性能,并在各ABR容积负荷条件下考察MBR容积负荷对MBR反应器硝化性能的影响.结果表明,在ABR进水容积负荷为1.51 kg·(m~3·d)~(-1)的条件下,系统A2隔室COD去除量最大,并在MBR容积负荷为0.462 kg·(m~3·d)~(-1)时,MBR反应器中实现了短程硝化,系统NH_4~+-N和TN去除率分别达到90%和72%以上,厌氧释磷量为7.41 mg·L~(-1),缺氧吸磷量达到15.42 mg·L~(-1),出水PO_4~(3-)-P浓度低于0.5 mg·L~(-1),这表明短程硝化更有利于强化ABR-MBR系统的反硝化除磷性能. 相似文献
3.
为了开发经济高效的生物脱氮工艺,研究了SBR中联氨对短程硝化反硝化的控制作用,考察了不同联氨投加量对短程硝化的影响。实验结果表明:在室温下,不控制溶解氧,p H为7.5~8.0时,投加7.5 mg/L联氨,亚硝氮积累效果最佳,其出水氨氮及亚硝氮浓度平均值分别为1.44,12.23 mg/L,均优于其他联氨投加量的监测结果;投加7.5 mg/L联氨的活性污泥中生物相种类和数量都优于未投加联氨的活性污泥,SEM图像显示活性污泥结构致密,紧凑,且菌落数量明显升高;从活性污泥的红外谱图可以看出,投加联氨与否,特征峰位置基本相同,但投加7.5 mg/L联氨的活性污泥EPS红外谱图峰强更高。 相似文献
4.
Rongchang WANG Xinmin ZHAN Yalei ZHANG Jianfu ZHAO 《Frontiers of Environmental Science & Engineering》2011,5(1):48-56
Nitrogen removal performance and nitrifying population dynamics were investigated in a redox stratified membrane biofilm reactor (RSMBR) under oxygen limited condition to treat ammonium-rich wastewater. When the N H 4 + - N loading rate increased from 11.1±1.0 to 37.2 ± 3.2 g N H 4 + - N · m - 2 · d - 1 , the nitrogen removal in the RSMBR system increased from 18.0±9.6 mgN·d-1 to 128.9±61.7 mgN·d-1. Shortcut nitrogen removal was achieved with nitrite accumulation of about 22.3 ± 5.3 m g N O 2 - - N · L - 1 . Confocal micrographs showed the stratified distributions of nitrifiers and denitrifiers in the membrane aerated biofilms (MABs) at day 120, i.e., ammonia and nitrite oxidizing bacteria (AOB and NOB) were dominant in the region adjacent to the membrane, while heterotrophic bacteria propagated at the top of the biofilm. Real-time qPCR results showed that the abundance of amoA gene was two orders of magnitude higher than the abundance of nxrA gene in the MABs. However, the nxrA gene was always detected during the operation time, which indicates the difficulty of complete washout of NOB in MABs. The growth of heterotrophic bacteria compromised the dominance of nitrifiers in biofilm communities, but it enhanced the denitrification performance of the RSMBR system. Applying a high ammonia loading together with oxygen limitation was found to be an effective way to start nitrite accumulation in MABs, but other approaches were needed to sustain or improve the extent of nitritation in nitrogen conversion in MABs. 相似文献
5.
采用SBR反应器在间歇曝气模式下对搁置2个月的短程硝化污泥进行恢复,控制曝气量分别为120、100、80和60L·h-1,在温度为25℃、交替好氧/缺氧时间比为30 min/30 min条件下处理实际生活污水,进水氨氮浓度为50~80 mg·L~(-1),出水氨氮浓度分别在第12、18、21和21周期之后稳定在5 mg·L~(-1)以下,氨氮去除率均高达95.00%左右;第30、35、38和42周期时,亚硝氮积累浓度分别达到20.83、22.81、21.50和20.73 mg·L~(-1),硝氮出水浓度均低于0.5 mg·L~(-1),亚硝积累率均高于99%,氨氧化菌(AOB)活性最终均稳定在100.00%左右,而亚硝酸盐氧化菌(NOB)活性逐渐被抑制,4种曝气量下均成功实现了短程硝化的恢复. 相似文献
6.
7.
8.
曝气生物滤池中的亚硝酸盐积累及其影响因子 总被引:34,自引:4,他引:34
通过模型试验研究了曝气生物滤池脱氮过程中的亚硝酸盐积累现象,考察了运行条件对亚硝酸盐积累的影响.试验结果表明,曝气生物滤池在滤速1~2m/h、气水比3:1、水温20.5℃~26.5℃、进水氨氮负荷0.26~0.62kg/(m3·d)、总氮负荷0.28~0.63kg/(m33·d)和0.18~0.42kg/(m3·d)反应器内反应液和处理水连续监测结果、反应器内含氮化合物空间分布分析以及微生物数量及活性测定结果表明,反应器中出现了明显的亚硝酸盐积累现象,表现出显著的短程硝化反硝化特征.初步分析探讨了亚硝酸盐积累的形成机理和运行条件对亚硝酸盐积累的影响,认为反冲洗过程是最主要的影响因素,而曝气生物滤池的结构特征和运行方式是其能够出现亚硝酸盐积累,并进行短程硝化反硝化脱氮的主要原因. 相似文献
9.
Binbin Sheng Depeng Wang Xianrong Liu Guangxing Yang Wu Zeng Yiqing Yang Fangang Meng 《Frontiers of Environmental Science & Engineering》2020,14(6):93
10.
采用加入淀粉的短程硝化-反硝化一体化技术处理低碳含NH3-N催化剂废水。通过中试确定了适宜的工艺参数,并在工业化装置上进行了验证。试验结果表明:在DO为0.5 mg/L左右、淀粉加入量为0.25 kg/ m3、HRT=30 h的条件下,短程硝化-反硝化一体化技术具有较好的处理效果,NH3-N去除率大于97%,且具有较强的抗冲击负荷的能力; 出水的COD<100 mg/L,ρ(NH3-N)<10 mg/L,达到GB 8978—1996《污水综合排放标准》的一级排放标准。工业化装置的运行费用以NH3-N计为2.3 元/kg、以废水计为4.6 元/t。该法适用于中低浓度(ρ(NH3-N)<300 mg/L)废水的处理。 相似文献