排序方式: 共有60条查询结果,搜索用时 15 毫秒
1.
2.
以某长大高速公路隧道为例,结合我国隧道通风设计规范JTJ026.1-1999与PIARC2007标准(世界道路协会),针对不同行车速度,不同车辆更新情况、不同排放标准组合形式以及是否考虑NOx等情况,对各个不同工况的需风量分别进行计算,并从需风量计算方法、机动车排放量和污染物设计浓度三个方面对隧道需风量差异进行分析。研究结果表明:我国设计规范与PIARC2007存在较大差距,为了适应当前及今后我国交通量及机动车排放特点的发展趋势,我国现行规范应在机动车排放量、污染物设计浓度限值等方面做出必要改进以达到合理确定隧道需风量的目的。 相似文献
3.
A two-dimensional numerical model for evaluating the wind flow and pollutant dispersion within a street canyon was first developed using the FLUENT code, which was then validated against a wind tunnel experiment. Then, the effects of the upstream building width and upwind building arrangement on the airflow and pollutant dispersion inside an isolated street canyon were investigated numerically. The numerical results revealed that: (1) the in-canyon vortex center shifts downwards as the upstream building width increases; (2) the recirculation zone covers the entire upstream building roof for the cases when W/H = 0.5, 1.0, 1.5, and 2.0 (W is the upstream building width and H is the building height), whereas the flow reattaches the upstream building roof for the cases when W/H = 2.5 and 3.0; (3) when the upstream building width is shorter than the critical width WC (= 2H), an increase in the upstream building width leads to an increase in the pollution level on the leeward wall of the canyon and a decrease in the roof-level concentrations at the upstream building; (4) when the upstream building width is longer than the critical width, the roof-level concentrations at the upstream building are negligibly small and the pollution level on the leeward wall of the canyon is almost unaffected by a further increase in the upstream building width; (5) when the buildings are placed upwind of the canyon, the flow attaches the upstream building roof and, therefore, almost none of the pollutants are distributed on the upstream building roof; and (6) the pollution levels inside the canyon and on the downstream building roof increase significantly with the number of upwind buildings. 相似文献
4.
采场是煤矿生产的核心地带,而采场通风系统是确保采场作业安全,创造良好生产环境的重要环节。本文以采场风流流动及瓦斯运移理论为基础,通过现场试验、模型模拟试验及计算机模拟研究等方法,着重研究了中国常用的和有发展前途的走向长壁后退式U型通风方式、U+L型通曲方式、后退式Y型通风方式条件下采场风流流动及瓦斯运移规律。 相似文献
5.
6.
诱导喷嘴改进滤筒脉冲清灰效果的实验研究 总被引:3,自引:2,他引:1
改善清灰效果是提高滤筒除尘效率的关键和难点问题。运用自制脉冲喷吹实验台,采用诱导喷嘴(超音速引流喷嘴和气流散射器)对325 mm×660 mm滤筒进行脉冲喷吹清灰实验研究,并与采用普通喷吹孔的实验结果进行比较分析,得出采用诱导喷嘴时侧壁正压力峰值平均值是普通喷吹孔的1.465倍;且采用诱导喷嘴时各测点的不均衡系数为0.768~1.336,普通喷口为0.270~2.251,而不均衡系数越接近于1,其清灰效果越好;同时,采用诱导喷嘴时各测点基本在同一时刻达到正峰值。实验充分表明采用诱导喷嘴确保了滤筒长度方向上内壁清灰压力的均匀性,且对滤筒清灰效果有明显的改善作用。 相似文献
7.
8.
目的对大型气候实验室气流组织进行仿真分析,获得合理的气流组织设计方案。方法首先通过分析旋流风口的特性,建立旋流风口CFD简化模型,然后设计大型气候实验室气流组织形式,最后对极端低温和极端高温工况下不同温度、送风量和送风角度时的气流组织进行CFD仿真分析。结果低温工况时,地面温度升高将导致室内温度和温度不均匀度整体上升;高温工况时,气流难以抵达地面,且地面温度对高度5 m以下区域有显著影响,对5 m以上空间影响不显著,应增大送风角度,使送风射流方向尽可能向下,以改善地面附近温度均匀性。结论气流组织仿真分析方法和气流组织设计方案适用于大型气候实验室设计。 相似文献
9.
目的研究分析一种分解大型电子设备机架风冷气流条件的方法。方法以温差和Nu数作为描述传热效果的参数,使用相似对流的方法,使分解夹具中模块两侧的气流传热效果等效于大型机架中模块两侧的气流传热效果。结果气流在分解后,其在分解夹具中的冷却效果等效于分解前其在大型机架中的冷却效果。结论该分解方法能够有效地进行风冷气流条件分解,可以应用于实际工程。 相似文献
10.