摘    要:通过对离子色谱法测定降水中F^-、Cl^-、NO3^-、SO4^2- 测量不确定度的分析,找出导致不确定度的因素。对测量不确定度进行计算和评定,结果表明,影响其测量不确定度的主要因素是标准曲线精密度。

关 键 词:离子色谱法  阴离子  不确定度  评定
文章编号:1007-1504(2008)01-0059-03
修稿时间:2007-08-13

Uncertainty Evalation of Determination of part of Anion in Precipitation with Ion Chromatography
WANG Ling-ling. Uncertainty Evalation of Determination of part of Anion in Precipitation with Ion Chromatography[J]. Arid Environmental Monitoring, 2008, 22(1): 59-61
Authors:WANG Ling-ling
Affiliation:WANG Ling- ling(Sheyang Environmental Monitoring Station, Yancheng Jiangsu 224300, China)
Abstract:The paper calculated and assessed uncertainty on determining F^-、Cl^-、NO3^-、SO4^2- in precipitation by ion chromatography method. The results showed that determination uncertainty was mainly due to standard curve precision.