Institution:1. Laboratoire Roberval, UMR CNRS 6253, Université de Technologie de Compiègne, BP 20529, 60205 Compiègne Cedex, France;2. LTI, EA 3899, Université de Picardie Jules Verne, Avenue des Facultés, Le Bailly, 80025 Amiens Cedex 1, France;3. PFT INNOVALTECH, Rond-Point Joliot Curie, 02100 Saint Quentin, France
Abstract:This study investigates the experimental research of the appropriated conditions for the magnetic pulse welding of AA6060T6 tubular assembly. Some welding tests were performed with two process parameters: the charging voltage and the width of the air gap between the two parts to be welded. A torsion-shear test, associated with the material fracture surfaces observation, gives an insight about the appropriateness of the welding conditions. The failure mode of the destructive test gives a dimensional criterion of the weld that is used as weld quality. It appears that the voltage does not strongly affect the weld quality for a low gap. It is possible to find an optimal gap range giving a high weld length. When the gap is too small, it is necessary to increase the pressure on the flyer, and some cracks appear in the material. Similarly, when the gap is too large, the high impact energy damages the welded interface.