关 键 词:稀释度  耗氧率(n)  检测偏差  准确度
文章编号:1003-6504(2005)增-0049-02
修稿时间:2004年11月15

Impact of Sample Dilution Degree on the Detection of BOD5
TANG Ya-ping.Impact of Sample Dilution Degree on the Detection of BOD5[J].Environmental Science and Technology,2005,28(Z1):49-50.
Authors:TANG Ya-ping
Abstract:Experiment was conducted to assess the impact of sample dilution degree on BOD-5 detection. Results showed that sample dilution degree obviously affected detection value of BOD-5 and oxygen consumption rate of culture, with best oxygen consumption rate of culture corresponding to sample dilution degree ranging in 39%~63%. Analytical data processing of BOD-5 was also discussed, and corresponding improvements were recommended.