首页 | 本学科首页   官方微博 | 高级检索  
     


Trace contamination with dioxin-like chemicals: evaluation of bioassay-based TEQ determination for hazard assessment and regulatory responses
Authors:Ilse Van Overmeire   George C. Clark   David J. Brown   Michael D. Chu   W. Marcus Cooke   Michael S. Denison   Willy Baeyens   Sarah Srebrnik  Leo Goeyens  
Affiliation:a Department of Pharmaco-Bromatology, Scientific Institute of Public Health, Juliette Wytsmanstraat 14, 1050- Brussels, Belgium;b Xenobiotic Detection Systems Inc., 1601 East Geer Street, Suite S, Durham, NC 27704, USA;c CCI, P.O. Box 810, Chapel Hill, NC 27514, USA;d Department of Environmental Toxicology, University of California, One Shields Avenue, Davis, CA 95616, USA;e Laboratory of Analytical and Environmental Chemistry, Vrije Universiteit Brussel, Pleinlaan 2, 1050- Brussels, Belgium
Abstract:Many recent dioxin contamination events have been traced back to poisoned animal feed or feed ingredients. Therefore, enforcement authorities placed limits on the levels of dioxins in food and feed or implemented strict monitoring and control programs. The levels in force are generally expressed as TEQ values, which inherently accepts the underlying hypothesis that the effects of dioxin-like chemicals are additive. TEQ determination involves either chemo-analysis, with high-resolution gas chromatography in combination with high-resolution mass spectroscopy, or bio-analysis. Bio-analytical methods, more particularly the reporter gene expression method CALUX, are advantageous due to their high throughput rate and low cost. Moreover, the CALUX methodology detects the overall dioxin-like toxicity, rather than the limited number of compounds investigated by chemo-analysis. Bioanalytical methods such as CALUX also differ from chemo-analysis in that the contribution of antagonistic as well as synergistic effects, which violate the additivity principle, can be detected. The application of bio-analytical methods can facilitate a broader assessment of public health risks by intensifying the current monitoring programs in terms of both sample numbers and types. Bio-analysis provides information on the total dioxin-like activity of the samples under study (hazard assessment); however, chemo-analysis is still needed to identify the predominant contaminants (congener identification) for risk management.
Keywords:Dioxins   Toxic equivalency (TEQ)   Bio-analysis   Chemical activated luciferase gene expression (CALUX)   Ah receptor
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号