首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Field use of semipermeable membrane devices (SPMDs) for passive air sampling of polycyclic aromatic hydrocarbons: Opportunities and limitations
Authors:MT Piccardo  A Stella  M Pala  D Balducci  F Valerio
Institution:1. PCFM Lab, School of Chemistry and Chemical Engineering, Sun Yat-Sen University, Guangzhou 510275, China;2. Materials Science Institute, Sun Yat-Sen University, Guangzhou 510275, China;1. Organic Polymer Chemistry Research Laboratory, Department of Chemistry, Isfahan University of Technology, Isfahan 84156-83111, Islamic Republic of Iran;2. Nanotechnology and Advanced Materials Institute, Isfahan University of Technology, Isfahan 84156-83111, Islamic Republic of Iran;3. Center of Excellence in Sensors and Green Chemistry, Department of Chemistry, Isfahan University of Technology, Isfahan 84156-83111, Islamic Republic of Iran;1. University of Sao Paulo, School of Public Health, Av. Dr. Arnaldo, 715, São Paulo, Brazil;2. Sao Paulo State Environmental Company, Av. Prof. Frederico Hermann Jr, 345, São Paulo, Brazil
Abstract:Semipermeable membrane devices (SPMDs) were used for measurements in air of twelve polycyclic aromatic hydrocarbons (PAHs) in two Genoa locations, both on building roofs, distant 300 m from each other. The first, site A, was in front a dismissing steel complex and the second, site B, was in an urban area overlooking a busy thoroughfare. SPMDs were deployed contemporary at the two sites, in nine monthly samplings, from April 2007 to May 2008. The amount of sequestered PAHs, in sites A and B, ranged between 61–267 ng SPMD?1 d?1 and 50–535 ng SPMD?1 d?1, respectively.PAHs profiles highlighted seasonal differences and suggested the possible role of different PAHs sources in the two areas. In particular, the contribution of remediation works of the steel complex was observed in site A. Moreover, a naphthalene leak from a tank, into the former industrial area, and a fire broke out near site A, were registered by time-integrated measurements of SPMDs.However, the strong dependence between amount of sequestered PAHs and air temperature needs further studies to distinguish between uptake rate variability and seasonal contribution of different sources. Finally, to measure air concentrations with reasonable accuracy, it should be very important to have certified sampling rates for all individual PAHs.
Keywords:
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号