首页 | 本学科首页   官方微博 | 高级检索  
     


Simultaneous DOAS and mist-chamber IC measurements of HONO in Houston,TX
Authors:Jochen Stutz  Hoon-Ju Oh  Sallie I. Whitlow  Casey Anderson  Jack E. Dibb  James H. Flynn  B. Rappenglück  B. Lefer
Affiliation:1. CNR - Institute of Atmospheric Pollution Research, Via Salaria Km 29.3, CP10, 00015 Monterotondo S., Rome, Italy;2. Research Consortium CORAM, Via Cristoforo Colombo 37/E, 441000 Ferrara, Italy;3. State Key Joint Laboratory for Environmental Simulation and Pollution Control, College of Environmental Sciences and Engineering, Peking University, No.5 Yiheyuan Road Haidian District, 100871, Beijing, China;1. Department of Environmental and Natural Resource Science, Faculty of Agriculture, Tokyo University of Agriculture and Technology, 3-5-8 Saiwai-cho, Fuchu, Tokyo 183-8538, Japan;2. Department of Applied Chemistry, Graduate School of Engineering, Osaka Prefecture University, 1-1, Gakuen-cho, Naka-ku, Sakai, Osaka 599-8531, Japan;3. Tokyo Metropolitan Research Institute for Environmental Protection, 1-7-5 Shinsuna, Koto-ku, Tokyo 136-0075, Japan
Abstract:Nitrous acid is an important component of nighttime N-oxide chemistry, and provides a significant source of both OH and NO in polluted urban air masses shortly after sunrise. Several recent studies have called for new sources of HONO to account for daytime levels much higher than are consistent with current understanding. However, measurement of HONO is problematic, with most in-situ techniques reporting higher values than simultaneous optical measurements by long-path DOAS, especially during daytime. The discrepancy has been attributed to positive interference in the in-situ techniques, negative interference in DOAS retrievals, the difficulty of comparing the different air masses sampled by the methods, or combinations of these.During August and September 2006, HONO mixing ratios from collocated long-path DOAS and automated mist-chamber/ion chromatograph (MC/IC) systems ranged from several ppbv during morning rush hour to daytime minima near 100 pptv. Agreement between the two techniques was excellent across this entire range during many days, showing that both instruments accurately measured HONO during this campaign. A small bias towards higher LP-DOAS observations at night can be attributed to slow vertical mixing leading to pronounced HONO profiles. A positive daytime bias of the MC/IC instrument during several days in late August/early September was correlated with photochemically produced compounds such as ozone, HNO3 and HCHO, but not with NO2, NOx, HO2NO2, or the NO2 photolysis rate. While an interferant could not be identified organic nitrites appear a possible explanation for our observations.
Keywords:
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号