Development and performance of the vehicle-mounted radiation monitoring equipment used in the Maralinga rehabilitation project
Authors:Long S  Martin L  Baylis S  Fry J
Institution:Australian Radiation Protection and Nuclear Safety Agency, 619-643 Lower Plenty Road, Yallambie 3085, Australia. stephen.long@arpansa.gov.au
Abstract:The rehabilitation of the former nuclear test site at Maralinga involved (among other processes) the removal of contaminated soil from an area of approximately 2.5 km2. The two most stringent rehabilitation criteria required measurements to ensure that no radioactive particle exceeding 100 kBq of 241Am activity, and no area of 1 ha exceeding 3 kBq/m2 of 241Am activity, remained in the rehabilitated area. The project timetable required that the area be scanned at the rate of approximately 3 ha/day. Two vehicle-mounted detection systems were developed and constructed to obtain the necessary measurements in the available timeframe. The scientific basis for the designs are presented, together with details of the selected equipment and technical solutions found. The performance of this equipment in the field is discussed in terms of both its scientific and technical operation. Based on the experience gained at Maralinga, improved versions of this equipment were produced under contract for the People's Republic of China.