自来水厂污泥的流动电流特性
引用本文:宗栋良,张锡辉,张光明.自来水厂污泥的流动电流特性[J].环境科学,2004,25(6):136-139.
作者姓名:宗栋良  张锡辉  张光明
作者单位:清华大学深圳研究生院环境工程与管理研究中心,深圳,518057;清华大学深圳研究生院环境工程与管理研究中心,深圳,518057;清华大学深圳研究生院环境工程与管理研究中心,深圳,518057
基金项目:国家高技术研究发展计划(863计划)项目(2002AA601120)
摘    要:以水厂混合污泥为对象,采用流动电流为特征参数分析加药量和pH对污泥沉降性能和脱水性能的影响,探讨流动电流技术在污泥处理中的适用性.结果表明,在污泥沉降性能方面,等电点处的投药量和pH值分别为8.9mg/L和7.25,实际最佳投药量和最佳pH为9.0mg/L和6.90.在污泥脱水方面,等电点处的投药量和pH值分别为25.0mg/L和9.25,实际最佳投药量和最佳pH为26.0mg/L和9.0.表明污泥调节的最佳投药量和最佳pH均处于流动电流值稍正的位置,可以用流动电流值作为单因子来控制污泥处理中的加药量,实现污泥加药的连续反馈控制.

关 键 词:水厂污泥  流动电流  沉降  脱水  调节机理
文章编号:0250-3301(2004)06-0136-04
收稿时间:9/7/2003 12:00:00 AM
修稿时间:2004/6/29 0:00:00

Streaming Current of Waterworks Sludge
ZONG Dong-liang,ZHANG Xi-hui and ZHANG Guang-ming.Streaming Current of Waterworks Sludge[J].Chinese Journal of Environmental Science,2004,25(6):136-139.
Authors:ZONG Dong-liang  ZHANG Xi-hui and ZHANG Guang-ming
Institution:Environmental Engineering & Management Center, Graduate School at Shenzhen, Tsinghua University, Shengzhen 518057, China.
Abstract:The applicability of streaming current in waterworks sludge treatment as indicator of coagulant dosage and pH control was investigated in this study. Experiments were conducted on sludge settling behaviors and dewatering processes. At the aspect of sludge settleability research showed the theoretical optimal dosage, pH was 8.9mg/L, 7.25, and the practical optimal dosage, pH was 9.0mg/L, 6.90. On the side of sludge dewaterability, the theoretical optimal dosage, pH was 25.0mg/L, 9.25, and the practical optimal dosage, pH was 26.0mg/L, 9.0. Results indicated that slightly positive streaming current coincided with the optimal dosage and pH. Thus streaming current can be used for continuous dosage feedback control as the single indicator.
Keywords:waterworks sludge  streaming current  settling behavior  dewatering  conditioning mechanisms