Use of Fourier transform infrared spectrometry as a continuous emission monitor
Authors:Zhuoxiong Mao  Jack DemirgianAlex Mathew  Richard Hyre
Abstract:This paper describes the use of a Fourier transfer infrared (FTIR) spectrometer, integrated with a sampling system and a control software, as a continuous emission monitor (CEM) for on-line measurement of most volatile organic and some inorganic compounds from various gas emissions. The time response of the system was tested experimentally, and can be approximated by a complete mixing model. In order to validate the measurement accuracy of the system, spiking tests are suggested. This paper discusses considerations in designing the spiking test and analyzing the spiking results. Field test results show that the FTIR-CEM has a stable performance and can be applied to stack emission monitoring, process monitoring, and unknown HAPs identification in many thermal treatment processes.
Keywords:
本文献已被 ScienceDirect 等数据库收录!