首页 | 本学科首页   官方微博 | 高级检索  
     


Evaluation of mercury speciation and removal through air pollution controldevices of a 190 MW boiler
Authors:Chengli Wu  Yan Cao  Zhongbing Dong  Chinmin Cheng  Hanxu Li  Weiping Pan
Affiliation:1. School of Chemical Engineering, Anhui University of Science and Technology, Huainan 232001, China;Institute for Combustion Science and Environmental Technology, Western Kentucky University, Bowling Gr
2. Institute for Combustion Science and Environmental Technology, Western Kentucky University, Bowling Green, Kentucky 42101, USA
3. School of Chemical Engineering, Anhui University of Science and Technology, Huainan 232001, China
Abstract:Air pollution control devices(APCDs) are installed at coal-fired power plants for air pollutant regulation.Selective catalytic reduction(SCR) and wet flue gas desulfurization(FGD) systems have the co-benefits of air pollutant and mercury removal.Configuration and operational conditions of APCDs and mercury speciation affect mercury removal efficiently at coal-fired utilities.The Ontario Hydro Method(OHM) recommended by the U.S.Environmental Protection Agency(EPA) was used to determine mercury speciation sim...
Keywords:mercury speciation  mercury removal  air pollution control device  field testing  
本文献已被 CNKI 维普 万方数据 ScienceDirect 等数据库收录!
点击此处可从《环境科学学报(英文版)》浏览原始摘要信息
点击此处可从《环境科学学报(英文版)》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号