首页 | 本学科首页   官方微博 | 高级检索  
     


Ambient Air Analyses Using Nonspecific Flame lonization and Electron Capture Detection Compared to Specific Detection by Mass Spectroscopy
Authors:Joachim D. Pleil  William A. McClenny  Karen D. Oliver
Affiliation:U.S. Environmental Protection Agency , Research Triangle Park , North Carolina , USA
Abstract:Ambient air samples from various studies were analyzed for a specific set of trace-level volatile organic compounds by using a gas chromatograph (GC) equipped with a flame ionization detector (FID) in parallel with an electron capture detector (ECD). The samples were then reanalyzed on a second GC system equipped with a mass selective detector (MSD). GC-FID/ECD data were compared to the nominally correct GC-MSD data to determine the accuracy of the nonspecific detectors, which often do not differentiate the targeted compound from Interfering compounds. Qualitative accuracy (capability for correctly identifying compounds on the basis of retention time only) and quantitative accuracy (capability for correctly measuring the concentration of an identified compound on the basis of peak area) were evaluated. Data are presented on a per-compound basis to provide the combined typical results from air samples collected in three geographic regions: Kanawha Valley, WV; Los Angeles, CA, area; and Houston, TX.