Evaluation of Canisters for Measuring Emissions of Volatile Organic Air Pollutants from Hazardous Waste Incineration |
| |
Authors: | Alex R Gholson Julia F Storm R K M Jayanty Robert G Fuerst Thomas J Logan M Rodney Midgett |
| |
Institution: | 1. Research Triangle Institute , Research Triangle Park , North Carolina , USA;2. U.S. Environmental Protection Agency , Research Triangle Park , North Carolina , USA |
| |
Abstract: | Regulation to control air emissions of toxic organic compounds require the collection and analysis of effluent gas from low level sources such as hazardous waste incinerators. The standard SW- 846 Method specifies the use of Tenax and Tenax/charcoal adsorbent traps for collection of volatile organics from incinerators. This study evaluates passivated stainless steel canisters as an alternative to adsorbent traps to eliminate some of the problems associated with adsorbent sampling. Initially the stability of 18 nonpolar, volatile organic compounds was determined in Summa-treated stainless steel canisters with greater than 100 ppmv HCI and saturated with water vapor. All 18 components were stable for a twoweek period; however, an Interference caused a 10-fold increase In the FID response of trlchloroethylene, toluene, and chlorobenzene. No Interference of the ECD response was found for any of the 11 compounds detected with the ECD including trlchloroethylene. A pilot scale incinerator was sampled using canisters, and the destruction efficiency of 1,1,1-trichloroethane was determined at a concentration of less than 0.5 ppbv while determining 1,1-dichloroethylene, the major product of Incomplete combustion, at a concentration of 8000 ppbv from the same sample. |
| |
Keywords: | |
|
|