电除尘器改造为电袋复合除尘器的实践 |
| |
引用本文: | 胡明.电除尘器改造为电袋复合除尘器的实践[J].电力环境保护,2011(5):19-22. |
| |
作者姓名: | 胡明 |
| |
作者单位: | 中石化集团资产经营管理有限公司扬子石化分公司热电厂; |
| |
基金项目: | 扬子石化技改技措项目(A0915002;A0915001) |
| |
摘 要: | 介绍了扬子热电厂1~7号炉电除尘器改造为电袋复合除尘器的工程实践,分析了电袋复合除尘器的关键技术及运行情况。改造后,电袋复合除尘器出口烟尘浓度≤30mg/m3,满足排放要求。
|
关 键 词: | 电除尘器 改造 排尘浓度 |
Engineering application of ESP-FF reformation from ESP |
| |
Abstract: | The technical program of ESP reformed to ESP-FF in No.1 to No.7 boilers of Yangzi Thermal Power Plant were introduced.The key technique of ESP-FF were analyzed.After reformation,the dust emission levels of the ESP-FF reached the environmental protection standards,which was lower than 30 mg/m3. |
| |
Keywords: | electrostatic precipitator reformation dust emission concentration |