首页 | 本学科首页   官方微博 | 高级检索  
     检索      

石墨毡电极预处理模拟邻甲酚废水
引用本文:武彦斌,王三反,张学敏,陈霞.石墨毡电极预处理模拟邻甲酚废水[J].化工环保,2014,34(4):311-315.
作者姓名:武彦斌  王三反  张学敏  陈霞
作者单位:1. 兰州交通大学 环境与市政工程学院寒旱区水资源综合利用教育部工程研究中心,甘肃 兰州 730070;;2.聊城大学 建筑工程学院,山东 聊城 252059
基金项目:国家“十二五”科技支撑计划项目(2012BAF03B06)
摘    要:采用聚丙烯腈基石墨毡电极,以NaCl为电解质,在恒流电解的条件下,对质量浓度为1 000 mg/L、COD=3 672 mg/L的模拟邻甲酚废水进行预处理。研究了电解时间、初始废水pH、NaCl加入量、电流密度对邻甲酚去除率的影响,考察了废水的COD变化,并探讨了反应机理。实验结果表明:石墨毡电极具有较好的导电性、吸附性,对邻甲酚具有较好的电化学氧化性能;常温常压下,初始废水pH为6~7、电流密度为90 A/m2、向300 mL废水中加入0.5 g NaCl时,经4 h电解,邻甲酚的去除率达到97.1%,COD的去除率达到47.3%;处理后废水的BOD5/COD由0.04提高至0.33,可不经稀释直接进行生物处理。

关 键 词:石墨毡电极  邻甲酚  电化学法  预处理  
收稿时间:2013-11-26

Pretreatment of Simulated o-Cresol-containing Wastewater with Graphite Felt Electrode
Wu Yanbin,Wang Sanfan,Zhang Xuemin,Chen Xia.Pretreatment of Simulated o-Cresol-containing Wastewater with Graphite Felt Electrode[J].Environmental Protection of Chemical Industry,2014,34(4):311-315.
Authors:Wu Yanbin  Wang Sanfan  Zhang Xuemin  Chen Xia
Institution:1. Engineering Research Center of Ministry of Education for Water Resources Utilization in Cold and Droughty Region,School of Environmental and Municipal Engineering,Lanzhou Jiaotong University,Lanzhou Gansu 730070,China;2.School of Architecture and Civil Engineering,Liaocheng University,Liaocheng Shandong 252059,China
Abstract:The simulated o-cresol-containing wastewater with 1 000 mg/L of o-cresol mass concentration and 3 672 mg/L of COD was pretreated by constant-current electrolysis using the polyacrylonitrile based graphite felt as electrode and NaCl as electrolyte. The factors affecting the o-cresol removal rate were investigated,the changes of the wastewater COD were studied,and the reaction mechanism was discussed. The experimental results show that:The graphite felt electrode has a good conductivity,adsorbability and electrochemical oxidation activity to o-cresol;Under the normal temperature and pressure,when the initial wastewater pH is 6-7,the current density is 90 A/m2,0.5 g NaCl is added into 300 mL wastewater and the electrolysis time is 4 h,the removal rate of o-cresol and COD are 97.1% and 47.3% respectively;The BOD5/COD is increased from 0.04 to 0.33,which indicates that the pretreated wastewater can be directly treated by biological process without dilution.
Keywords:graphite felt electrode  -cresol  electrochemical method  pretreatment  
本文献已被 CNKI 等数据库收录!
点击此处可从《化工环保》浏览原始摘要信息
点击此处可从《化工环保》下载免费的PDF全文