首页 | 本学科首页   官方微博 | 高级检索  
     


Mass spectrometry up to 1 million mass units for the simultaneous detection of primary soot and of soot precursors (nanoparticles) in flames
Authors:Grotheer Horst-Henning  Pokorny Heinz  Barth Karl-Ludwig  Thierley Marcus  Aigner Manfred
Affiliation:DLR Institute of Combustion Technology, Pfaffenwaldring 38, 70569 Stuttgart, Germany. hh.grotheer@dlr.de
Abstract:A hybrid setup consisting of low pressure burner, flow reactor and photo-ionization mass spectrometer was used for the simultaneous detection of primary soot and of flame generated nanoparticles precursing soot. The studied flames were low pressure (120-180 mbar) C2H4/O2 flames surrounded by an N2 shield. The flow reactor was not used in this study. Through variation of the burner conditions (stoichiometry, sampling height) it could be shown that nanoparticles and soot are entirely independent species. The former, in particular, are found very early in the flame and their concentration profiles do not vary very much throughout the flame. This renders the possibility that nanoparticles are emitted together with soot and consequently may constitute an additional environmental hazard. Photo-ionization mass spectrometry is well suited for the detection of these particles.
Keywords:
本文献已被 PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号