首页 | 本学科首页   官方微博 | 高级检索  
     


Analysis of PV module connected in different configurations under uniform and non-uniform solar radiations
Authors:R. Pon Vengatesh  S. Edward Rajan
Affiliation:Department of Electrical and Electronics Engineering, Mepco Schlenk Engineering College, Sivakasi, Tamil Nadu, India
Abstract:This paper focuses on investigating the current--voltage (I--V) and power--voltage (P--V) characteristics of a photovoltaic (PV) module connected in various configurations like series, parallel, and series-parallel. The performance analysis of PV module has been carried out under uniform and non-uniform conditions such as change in irradiation (passing clouds), change in temperature, accumulation of dust, and change in wind speed using MATLAB-Simulink environment. From the observed results, it has been indicated that for a given number of PV modules, the array configurations affect the maximum available output power and more local maxima are found under partially shaded conditions. Moreover, the comparative analysis of PV module has been performed for various configurations under the above disturbances. From the results, it is evident that even under non-uniform conditions, the parallel configuration of PV modules is more prominent and maximum output power is obtained. Further, parallel layout is particularly convenient for minimizing shadowing effects. The parameters of the PV module have been obtained from the manufacturer datasheet (KC200GT) for these investigations.
Keywords:Parallel  PV characteristics  PV module  series  series–parallel configurations  uniform and non-uniform solar radiations