首页 | 本学科首页   官方微博 | 高级检索  
     检索      

特大型冷却塔及冷水机组房噪声治理
引用本文:孙光苏,孙天镭.特大型冷却塔及冷水机组房噪声治理[J].环境工程,1998,16(2):51-53.
作者姓名:孙光苏  孙天镭
作者单位:武汉船舶设计研究所
摘    要:本文对特大型冷却塔及冷水机组房的噪声特性进行了测量分析。根据其噪声源特性,采取了加装进排气消音器、吸声、隔声、减振等综合治理方案。治理后的实测结果表明:该项噪声治理工程投资少,达到标准的要求。

关 键 词:大型冷却塔  噪声治理

NOISE CONTROL OF LARGE WATER COOLING TOWER AND ITS ROOM OF WATER COOLING MACHINE SETS
Abstract:Noise charactertics of the water cooling tower and its room of water cooling machine sets have been measured and analysed in this paperAccording to the noise source charactertics,we have taken effective measures to control the noise and vibration,suchvas inlet and exhaust muffler,sound absorptiou,sound insulation and reduction of pipe vibration and so onFinal measured results after control has shown that noise level around enviroments is less than 5odB(A) and satisfies the national standards
Keywords:large water cooling tower and noise control