Workplace and Environmental Air Contaminant Concentrations Measured by Open Path Fourier Transform Infrared Spectroscopy: A Statistical Process Control Technique to Detect Changes from Normal Operating Conditions
Authors:Maureen Simonds Malachowski  Steven P Levine  Gary Herrin  Robert C Spear  Michael Yost  Zhou Yi
Institution:1. University of Michigan , Ann Arbor , Michigan , USA;2. University of California , Berkeley , California , USA
Abstract:Open path Fourier transform infrared (OP-FTIR) spectroscopy is a new air monitoring technique that can be used to measure concentrations of air contaminants in real or near-real time. OP-FTIR spectroscopy has been used to monitor workplace gas and vapor exposures, emissions from hazardous waste sites, and to track emissions along fence lines. This paper discusses a statistical process control technique that can be used with air monitoring data collected with an OP-FTIR spectrometer to detect departures from normal operating conditions in the workplace or along a fence line. Time series data, produced by plotting consecutive air sample concentrations in time, were analyzed. Autocorrelation in the time series data was removed by fitting dynamic models. Control charts were used with the residuals of the model fit data to determine if departures from defined normal operating conditions could be rapidly detected. Shewhart and exponentially weighted moving average (EWMA) control charts were evaluated for use with data collected under different room air flow and mixing conditions.

Under rapidly changing conditions the Shewhart control chart was able to detect a leak in a simulated process area. The EWMA control chart was found to be more sensitive to drifts and slowly changing concentrations in air monitoring data. The time series and statistical process control techniques were also applied to data obtained during a field study at a chemical plant. A production area of an acrylonitrile, 1,3-butadiene, and styrene (ABS) polymer process was monitored in near-real time. Decision logics based on the time series and statistical process control technique introduced suggest several applications in workplace and environmental monitoring. These applications might include signaling of an alarm or warning, increasing levels of worker respiratory protection, or evacuation of a community, when gas and vapor concentrations are determined to be out-of-control.
Keywords:
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号