首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Effect of media heights on the performance of biological aerated filter
Authors:HU Yong-you and WANG Li-li
Institution:1. School of Environmental Science and Engineering, South China University of Technology, Guangzhou 510640, China
2. Department of Environmental Engineering, Jinan University, Guangzhou 510632, China
Abstract:The optimum media height of carbon oxidation and nitrification in a down-flow biological aerated filter was determined, and the distribution of the heterotrophic and nitrifying populations through studying the changes of organic carbon contents and ammonia concentration at different media height was got. The results showed that as a down flow BAF with granular media, the active layer of nitrifiers was deeper than heterotrophs in BAF. And the optimum media height for the removal of SS, COD(Cr) and NH4+ -N was 40 cm, 60 cm and 80 cm respectively. The removal efficiency of SS, COD(Cr), and NH4+ -N was 79.1%, 63.9% and 96.4% respectively under the influent COD(Cr), and NH4+ -N of 122.1 mgCOD(Cr)/L and 14.84 mgNH4+ -N/L, the influent flux of 15.8 L/h, air to liquid ratio of 3:1.
Keywords:biological aerated filter  bed material height  sewage treatment
本文献已被 CNKI 维普 万方数据 PubMed 等数据库收录!
点击此处可从《环境科学学报(英文版)》浏览原始摘要信息
点击此处可从《环境科学学报(英文版)》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号