Pre-treatment of pyridine wastewater by new cathodic–anodic-electrolysis packing
作者姓名:Yang Jin  Qinyan Yue  Kunlun Yang  Suqing Wu  Shengjie Li  Baoyu Gao  Yuan Gao
摘    要:A novel cathodic–anodic-electrolysis packing(CAEP) used in the treatment of pyridine wastewater was researched, which mainly consisted of 4,4′-diamino-2,2′-disulfonic acid(DSD acid) industrial iron sludge. The physical properties and morphology of the packing were studied. The CAEP was used in a column reactor during the pretreatment of pyridine wastewater. The influence of p H, hydraulic retention time(HRT), the air–liquid ratio(A/L)and the initial concentration of pyridine were investigated by measuring the removal of total organic carbon(TOC) and pyridine. The characterization results showed that the bulk density, grain density, water absorption percentage and specific surface area were 921 kg/m3,1086 kg/m3, 25% and 29.89 m~2/g, respectively; the removal of TOC and pyridine could reach50% and 58% at the optimal experimental conditions(p H = 3, HRT = 8 hr, A/L = 2). Notably,the surface of the packing was renewed constantly during the running of the filter, and the handling capacity was stable after running for three months.

关 键 词:Cathodic–anodic-electrolysis  packing  Pyridine  wastewater  pH  Hydraulic  retention  time  Air–liquid  ratio  Initial  concentration
收稿时间:2016/11/5 0:00:00
修稿时间:2017/2/24 0:00:00
本文献已被 CNKI 等数据库收录!