首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Thermal degradation of fluorotelomer treated articles and related materials
Authors:Yamada Takahiro  Taylor Philip H  Buck Robert C  Kaiser Mary A  Giraud Robert J
Institution:Environmental Engineering Group, University of Dayton Research Institute, 300 College Park, Dayton, OH 45469-0114, USA.
Abstract:This study reports the first known studies to investigate the thermal degradation of a polyester/cellulose fabric substrate ("article") treated with a fluorotelomer-based acrylic polymer under laboratory conditions conservatively representing typical combustion conditions of time, temperature, and excess air level in a municipal incinerator, with an average temperature of 1000 degrees C or greater over approximately 2s residence time. The results demonstrate that the polyester/cellulose fabric treated with a fluorotelomer-based acrylic polymer is destroyed and no detectable amount of perfluorooctanoic acid (PFOA) is formed under typical municipal incineration conditions. Therefore, textiles and paper treated with such a fluorotelomer-based acrylic polymer disposed of in municipal waste and incinerated are expected to be destroyed and not be a significant source of PFOA in the environment.
Keywords:
本文献已被 PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号