The use of waste basic oxygen furnace slag and hydrogen peroxide to degrade 4-chlorophenol
Authors:Yuan-Shen Li  
Institution:1. Department of Geography and Environmental Sciences, Northumbria University, Newcastle-upon-Tyne, NE1 8ST, UK;2. Department of Earth and Environmental Sciences, University of Texas at Arlington, Arlington, TX 76019, USA;3. Department of Applied Sciences, Northumbria University, Newcastle-upon-Tyne, NE1 8ST, UK;1. College of Materials Science and Engineering, Chongqing University, Chongqing 400044, PR China;2. Department of Scientific Research, Chongqing University of Education, Chongqing 400065, PR China;1. University of Cergy-Pontoise, Laboratoire de Mécanique & Matériaux du Génie Civil, EA 4114, F-95000 Cergy-Pontoise, France;2. Université Paris Ouest Nanterre la Défense, Laboratoire Energétique Mécanique Electromagnétisme (LEME) EA4416, 50 rue de Sèvres, 92410 Ville d’Avray, France
Abstract:A new treatment method is developed to degrade 4-chlorophenol (4-cp) and its oxidation intermediates. The experimental results of this research demonstrate that 4-cp and its oxidation intermediates can be decomposed completely by basic oxygen furnace slag (BOF slag) with hydrogen peroxide (H2O2) in an acid solution. The factors that effect the treatment efficiency were studied including initial concentration of 4-cp, pH of the solution, concentration of H2O2 and amount of BOF slag. The BOF slags are final waste materials in the steel making process. The major components of BOF slag are CaO, SiO2, Fe2O3, FeO, MgO and MnO. As the BOF slag in an acid solution, FeO and Fe2O3 can be dissociated to produce ferrous ion and ferric ion. Ferrous ion reacts with hydrogen peroxide to form “Fenton's reagent” which can produce hydroxyl radicals (OH.). Hydroxyl radical possession of high oxidation ability can oxidize organic chemicals effectively. Results show that 100 mg/l of 4-cp is decomposed completely within 30 min by 438.7 g/l BOF slag with 8.2 mM hydrogen peroxide in pH=2.8±0.2 solution. The COD value of the solution is reduced from 290 to 90 mg/l. The factors studied which affect the 4-cp decomposition efficiency were the hydrogen peroxide concentration, BOF slag concentration, pH of the solution and initial concentration of 4-cp. Because large amounts of Fe2O3 and FeO are present in the BOF slag, the BOF slag not only has a high treatment efficiency, but also can be used repeatedly.
Keywords:Basic oxygen furnace slag  Fenton's reagent  H2O2  4-chlorophenol
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号