首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Effect of sewer headspace air-flow on hydrogen sulfide removal by corroding concrete surfaces
Authors:Nielsen Asbj?rn Haaning  Hvitved-Jacobsen Thorkild  Vollertsen Jes
Institution:Section of Water and Soil, Department of Civil Engineering, Aalborg University, Sohngaardsholmsvej 57, 9000 Aalborg, Denmark.
Abstract:Hydrogen sulfide adsorption and oxidation by corroding concrete surfaces at different air-flows were quantified using a pilot-scale sewer reactor. The setup was installed in an underground sewer research station with direct access to wastewater. Hydrogen sulfide gas was injected into the headspace of the sewer reactor once per hour in peak concentrations of approximately 500 ppmv. The investigated range of sewer air-flows was representative for natural ventilated sewer systems, and covered both laminar and turbulent conditions. The experiments demonstrated a significant effect of sewer air-flow on the kinetics of hydrogen sulfide removal from the sewer headspace. From the lowest to the highest air-flow investigated, the rate of adsorption and oxidation increased more than threefold. At all air-flows, the reaction kinetics followed a simple n-th order rate equation with a reaction order of 0.8. The effect of air-flow on hydrogen sulfide adsorption and oxidation kinetics was quantified by a simple empirical equation.
Keywords:
本文献已被 PubMed 等数据库收录!