首页 | 本学科首页   官方微博 | 高级检索  
     

Electropolymerized poly(Toluidine Blue)-modified carbon felt for highly sensitive amperometric determination of NADH in flow injection analysis
引用本文:Yasushi Hasebe,Yue Wang,Kazuya Fukuoka. Electropolymerized poly(Toluidine Blue)-modified carbon felt for highly sensitive amperometric determination of NADH in flow injection analysis[J]. 环境科学学报(英文版), 2011, 23(6): 1050-1056. DOI: 10.1016/S1001-0742(10)60513-X
作者姓名:Yasushi Hasebe  Yue Wang  Kazuya Fukuoka
作者单位:Yasushi Hasebe(Department of Life Science and Green Chemistry, Saitama Institute of Technology, 1690 Fusaiji, Fukaya,Saitama 369-0293, Japan;Department of Materials Science and Engineering, Graduate School of Engineering,Saitama Institute of Technlogy, 1690 Fusaiji, Fuk);Yue Wang(Department of Materials Science and Engineering, Graduate School of Engineering,Saitama Institute of Technlogy, 1690 Fusaiji, Fukaya, Saitama 369-0293, Japan;School of Chemical Engineering, University of Sciences and Technology, Anshan 114044, China);Kazuya Fukuoka(Department of Life Science and Green Chemistry, Saitama Institute of Technology, 1690 Fusaiji, Fukaya,Saitama 369-0293, Japan)
基金项目:This research was financially supported in part by theOpen Research Center Project of the Ministry of Education,Science and Culture of Japan.
摘    要:

关 键 词:NADH  甲苯胺蓝  流动注射分析  安培  敏感  碳毡  烟酰胺腺嘌呤二核苷酸  测定
收稿时间:2010-10-12
修稿时间:2011-01-18

Electropolymerized poly(Toluidine Blue)-modified carbon felt for highlysensitive amperometric determination of NADH in flow injection analysis
Yasushi Hasebe,Yue Wang and Kazuya Fukuoka. Electropolymerized poly(Toluidine Blue)-modified carbon felt for highlysensitive amperometric determination of NADH in flow injection analysis[J]. Journal of environmental sciences (China), 2011, 23(6): 1050-1056. DOI: 10.1016/S1001-0742(10)60513-X
Authors:Yasushi Hasebe  Yue Wang  Kazuya Fukuoka
Affiliation:1. Department of Life Science and Green Chemistry, Saitama Institute of Technology, 1690 Fusaiji, Fukaya,Saitama 369-0293, Japan;Department of Materials Science and Engineering, Graduate School of Engineering,Saitama Institute of Technlogy, 1690 Fusaiji, Fuk
2. Department of Materials Science and Engineering, Graduate School of Engineering,Saitama Institute of Technlogy, 1690 Fusaiji, Fukaya, Saitama 369-0293, Japan;School of Chemical Engineering, University of Sciences and Technology, Anshan 114044, China
3. Department of Life Science and Green Chemistry, Saitama Institute of Technology, 1690 Fusaiji, Fukaya,Saitama 369-0293, Japan
Abstract:Poly(pheniothiazine) films were prepared on a porous carbon felt (CF) electrode surface by an electrooxidative polymerization ofthree phenothiazine derivatives (i.e.,Tthionine (TN), Toluidine Blue (TB) and Methylene Blue (MB)) from 0.1 mol/L phosphate buffersolution (pH 7.0). Among the three phenothiazies, the poly(TB) film-modified CF exhibited an excellent electrocatalytic activity forthe oxidation of nicotinamide adenine dinucleotide reduced form (NADH) at +0.2 V vs. Ag/AgCl. The poly(TB) film-modified CFwas successfully used as working electrode unit of highly sensitive amperometric flow-through detector for NADH. The peak currents(peak heights) were almost unchanged, irrespective of a carrier flow rate ranging from 2.0 to 4.1 mL/min, resulting in the measurementof NADH (ca. 30 samples/hr) at 4.1 mL/min. The peak current responses of NADH showed linear relationship over the concentrationrange from 1 to 30 mol/L (sensitivity: 0.318 A/( mol/L); correlation coefficient: 0.997). The lower detection limit was found to be0.3 mol/L (S/N = 3).
Keywords:poly(phenothiazine)   Toluidine Blue   electropolymerization   carbon felt   NADH   flow injection analysis
本文献已被 维普 万方数据 PubMed 等数据库收录!
点击此处可从《环境科学学报(英文版)》浏览原始摘要信息
点击此处可从《环境科学学报(英文版)》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号