Abstract: | ABSTRACT Information about the ratio between indoor and outdoor concentrations (IO ratios) of air pollutants is a crucial component in human exposure assessment. The present study examines the relationship between indoor and outdoor concentrations as influenced by the combined effect of time patterns in outdoor concentrations, ventilation rate, and indoor emissions. Two different mathematical approaches are used to evaluate IO ratios. The first approach involves a dynamic mass balance model that calculates distributions of transient IO ratios. The second approach assumes a linear relationship between indoor and outdoor concentrations. We use ozone and benzene as examples in various modeling exercises. The modeled IO ratio distributions are compared with the results obtained from linear fits through plots of indoor versus outdoor concentrations. |
| |