Metal Emissions from Joule-Heated Vitrification Systems
Authors:Thomas J Overcamp  John M Harden  Connie A Cicero-Herman  Dennis F Bickford
Institution:1. Environmental Engineering and Science , Clemson University , Anderson , South Carolina , USA tjvrc@clemson.edu;3. Environmental Engineering and Science , Clemson University , Anderson , South Carolina , USA;4. Savannah River Technology Center, Westinghouse Savannah River Company , Aiken , South Carolina , USA
Abstract:ABSTRACT

Vitrification demonstrations were conducted for surrogates of three inorganic wastewater sludges in a high-temperature, refractory-lined, slurry-fed melter. The total par-ticulate concentrations and melter decontamination factors were determined for selected elements. The decontamination factors were less than 10 for cadmium and lead in all three demonstrations. The decontamination factors for chromium were less than 30 in the two demonstrations using refractories containing chromium, and they were greater than 150 for the demonstrations using refractories without chromium. Except for one demonstration on a surrogate waste with a high sulfate content, decontamination factors were above 80 for the other heavy metals in the demonstrations.